Filtern
Erscheinungsjahr
- 2015 (6) (entfernen)
Dokumenttyp
Sprache
- Englisch (6)
Referierte Publikation
- ja (6) (entfernen)
Schlagworte
- Acoustic emission (6) (entfernen)
Recently developed new transducers for ultrasonic transmission, which can be embedded right into concrete, are now used for non-destructive permanent monitoring of concrete. They can be installed during construction or thereafter. Large volumes of concrete can be monitored for changes of material properties by a limited number of transducers. The transducer design, the main properties as well as installation procedures are presented. It is shown that compressional waves with a central frequency of 62 kHz are mainly generated around the transducer's axis. The transducer can be used as a transmitter or receiver. Application examples demonstrate that the transducers can be used to monitor concrete conditions parameters (stress, temperature,
) as well as damages in an early state or the detection of acoustic events (e.g., crack opening). Besides application in civil engineering our setups can also be used for model studies in geosciences.
This study evaluates the sensitivity of embedded ultrasonic sensors to detect propagating cracks within concrete. Because of the sensors constant coupling to the medium, highly sensitive data analysis techniques, such as the correlation between signals and their attenuation, are applied to detect changes in the signal due to propagating cracks.
The accuracy of the detected onset of the crack is evaluated with the nondestructive testing methods acoustic emission and Digital Image Correlation. It shows that with embedded ultrasonic sensors crack propagation can be detected before it is visible on the surface of the concrete.
We report on the successful application of distributed acoustic sensing (DAS) to the detection of partial discharge (PD). A detection limit of about 1 nC discharge magnitude was achieved for PD in a real-scale model of a high voltage termination. Dedicated ultrasonic fibre-optic transducers were interrogated using coherent optical time-domain Rayleigh backscatter reflectometry (C-OTDR). Random quadrature demodulation was employed for retrieving relevant acoustic information from the raw C-OTDR backscatter traces. To our knowledge, our results are a first-time demonstration that quasi-distributed fibre-optic acoustic sensing is a candidate technology for the acoustic partial discharge monitoring of power cable joints and terminations.
This paper presents the analysis of crack propagation in strain-hardening cement-based composite (SHCC) under tensile and flexural load by using acoustic emission (AE). AE is a non-destructive technique to monitor the development of structural damage due to external forces. The main objective of this research was to characterise the cracking behaviour in SHCC in direct tensile and flexural tests by using AE. A better understanding of the development of microcracks in SHCC will lead to a better understanding of pseudo strain-hardening behaviour of SHCC and its general performance. ARAMIS optical deformation analysis was also used in direct tensile tests to observe crack propagation in SHCC materials. For the direct tensile tests, SHCC specimens were prepared with polyvinyl alcohol (PVA) fibre with three different volume percentages (1%, 1.85% and 2.5%). For the flexural test beam specimens, only a fibre dosage of 1.85% was applied. It was found that the application of AE in SHCC can be a good option to analyse the crack growth in the specimens under increasing load, the location of the cracks and most importantly the identification of matrix cracking and fibre rupture or slippage.
Time reversal techniques are used in ocean acoustics, medical imaging, seismology, and non-destructive evaluation to backpropagate recorded signals to the source of origin. We demonstrate experimentally a technique which improves the temporal focus achieved at the source location by utilizing deconvolution. One experiment consists of propagating a signal from a transducer within a concrete block to a single receiver on the surface, and then applying time reversal or deconvolution to focus the energy back at the source location. Another two experiments are run to study the robust nature of deconvolution by investigating the effect of changing the stabilization constant used in the deconvolution and the impact multiple sources have upon deconvolutions focusing abilities. The results show that we are able to generate an improved temporal focus at the source transducer using deconvolution while maintaining the robust nature of time reversal. Additionally, deconvolutions costs are negligible due to it being a preprocessing step to the recorded data. The technique can be applied for detailed investigation of the source mechanisms (e.g. cracks) but also for monitoring purposes.
Partial discharge in polymeric insulation of high voltage equipment causes cumulative damage that progressively deteriorates the insulation, leading to eventual failure. The electrical detection of related discharge current pulses may be challenged by electromagnetic interference from the environment. In such situations the detection of acoustic emission from partial discharge can greatly enhance its detectability, especially when electromagnetically immune fiber-optic acoustic sensors are used. During experiments involving such fiber-optic sensors that were specifically designed for the detection of partial discharge in elastomeric insulation, an unexpected type of acoustic emission was observed in silicone elastomer specimens with tip–plate electrode configurations and under DC electrical stress. We present and discuss experimental results that indicate space charge injection and subsequent spontaneous dynamical processes as the source of the detected acoustic emission. We use sensitive conventional partial discharge measurement instrumentation to show that the apparent acoustic efficiency of the processes leading to the observed acoustic emission is very high. Acoustic emission triggered by discharge events with individual apparent charge values of only a few femtocoulombs could be detected.