The objective of the report is to present the state-of-the art of non-destructive testing methods and technologies for the inspection of thick, heavily-reinforced structures, (e.g. found in nuclear power plants). Wall thicknesses can be in excess of one meter and the structures often have increased steel reinforcement density. The accessibility for any testing method may be limited due to the presence of liners and other components such as cast-in-place items. Testing methods have to provide solutions for tasks such as locating failure (inclusions, corrosion, voids, delaminations) in the structures or the assessment of the condition of the structure in general.
Grouting defects, e.g. in post-tensioned structures or piped anchors may be identified by ultrasonic imaging. Since several years experiences are carried out with false color displayed phase values, which enable distinct localization of ungrouted regions.
In this contribution we report on progress in localizing grouting defects in tendon ducts, when they are only partly grouted and the unfilled part is not orientated into the direction of the measuring surface. This is frequently the case e.g. for box girder structures.
Düring the project specimens containing different types of grouting faults are investigated in Order to optimize measuring and evaluation techniques. A handheld linear array System (commercially available) is applied for fast 2D-measurement and subsequent phase sensitive 3D-imaging (new Software development).
In a large concrete wall specimen tendon ducts and real prestressing Systems containing grouting defects were built in. The ducts are partly covered by non prestressed reinforcement bars in order to investigate its disturbing influence. These included objects were investigated afterwards with the described methods. We report on large area measuring results, which were partly verified by y-radiography. In the frame of practical application results of measuring the position and extend of a blockade within a posttensioned structure are presen ted.
Die immer komplexere Konstruktionsweise von Neubauten einerseits und die alternde Infrastruktur andererseits erfordern in manchen Fällen eine dauerhafte Überwachung, um besondere Einwirkungen und gegebenenfalls Schädigungen rechtzeitig und genau zu erkennen. Hierfür ist eine Vielzahl von Methoden und Sensoren verfügbar. Das Portfolio weist aber insbesondere bei der Detektion langsamer, räumlich begrenzter Veränderungen Lücken auf. Hierfür sind bisher sehr aufwändige Untersuchungen oder Installationen notwendig.
In der vorliegenden Arbeit werden Sensoren und zugehörige Auswertemethoden für die Ultraschalltransmission vorgestellt, die sich für die zerstörungsfreie, dauerhafte Überwachung von Beton eignen. Direkt oder nachträglich in Betonkonstruktionen eingebaut, ermöglichen sie eine nicht nur lokale, sondern größere Raumbereiche umfassende Dauerüberwachung von Änderungen der Materialeigenschaften.
Das Prinzip der Ultraschalltransmission und die verschiedenen Einflussparameter werden vorgestellt. Zu letzteren gehören neben der Belastung und Schädigung auch Umweltparameter wie Temperatur und Feuchte. Verschiedene Methoden zur Datenanalyse, wie z. B. die Codawelleninterferometrie, ermöglichen eine Detektion kleinster Veränderungen. Die in den Beton einzubettenden Ultraschallsensoren werden vorgestellt und ihr Einbau und Betrieb beschrieben. Als Beispiele für Anwendungen werden Frost-Tauwechsel-Experimente im Labor, die Detektion von lokalen Lasten im Technikumsmaßstab und der Einsatz an realen Brücken diskutiert. Die Sensoren sind zum Teil bereits seit mehreren Jahren in Probeobjekte eingebettet und liefern zuverlässig wertvolle Daten.-------------------------------------------------------------------------------------------------------------------------------------------------------------
Monitoring of concrete constructions by embedded ultrasonic sensors:
Challenging new constructions and the ageing infrastructure are increasing the demand for permanent monitoring of loads and damages. Various methods and sensors are used for this purpose. But the technologies available today have difficulties in detecting slowly progressing locally confined damages. Extensive investigations or instrumentations are required so far for this purpose.
In this study we present new sensors and data processing methods for ultrasonic transmission, which can be used for non-destructive permanent monitoring of concrete. They can be mounted during construction or thereafter. Larger volumes can be monitored by a limited number of sensors for changes of material properties.
The principles of ultrasonic transmission and influencing factors are presented. This latter include load, damages as well as environmental parameters as temperature or moisture. Various methods for data processing, e. g. coda wave interferometry are introduced. They allow the detection of very small changes in the medium. The embedded sensors are shown including mounting and operation. Application examples so far include small scale laboratory freeze-thaw experiments, localizing loads in larger concrete models and monitoring load effects on real structures. Some sensors are operating already for several years.
The research project "Ultrasonic Net for Concrete Monitoring (UNeCOM)" aims at developing a methodology for an embedded ultrasonic network for the condition assessment of infrastructure constructions. Civil engineering structures made of concrete, which are located in tectonically active regions or undergo special loading conditions, may require continuous monitoring. It is important to assess the condition of the building and its stability to recognise and classify the effect of a seismic event or evolving damage at early stages before failure occurs. Embedded ultrasonic sensors offer the possibility to detect changes in the material and degradation mechanisms from inside the structure in areas which are difficult or impossible to inspect otherwise. In contrast to conventional ultrasonic testing methods, where the concrete surfaces are scanned with ultrasound probes, this new approach uses sensors, which are embedded into concrete, eliminating the effect of variable coupling conditions between sensors and concrete. This method allows an integral detection of changes in the concrete structure, for example due to seismic activities, to detect mechanical impacts, as well as degradation of the material due to overloading. Such methods have great relevance especially for the monitoring of constructions like power plants, bridges, offshore structures and other structures with high technical safety requirements. The sensor network can be controlled remotely through the internet which is also being used for data transfer. The embedded sensor network is designed to monitor structural damage and concrete degradation globally with high sensitivity.
This paper studies the spatial and temporal spectral absorption of reflector signals of a 1.5 GHz ground penetrating radar (GPR) during a drying process of a brickwall from initial wet to later dry state. The non-stationary GPR signals were processed with short time-Fourier transform (STFT) and wavelet transform (WT) in a novel spatial-timefrequency (STF) domain. Spatial distribution of peak frequency at the direct wave (DW) across the antenna and a backwall reflection was studied to characterize the mechanism of spectral absorption of GPR wave. Results from WT were shown to be more preferred to those from STFT because the WT offers multiple resolutions to cope with both low and high frequency components in GPR wavelets but STFT does not. In addition to the traditional GPR signal interpretation in time-domain and our previous works on time–frequency domain, the analysis method operated in the STF domain provides another possibility of material characterization by GPR in large and field scale.
Laser induced breakdown spectroscopy (LIBS) - visualization of ion transport processes in concrete
(2014)
Laser induced breakdown spectroscopy (LIBS) is a combination of laser ablation and optical emission spectroscopy. Due to the possibility of direct measurements on the sample surface and a minimum of sample preparation investigations of building materials can be conducted quite fast. In combination with a scanning technique (translation stage or scanning mirrors head) the element distributions are evaluated with mm resolution. Thus the heterogeneity of the material may be considered. This is a significant advantage compared to standard procedures. LIBS measurements are also time and cost saving in comparison to standard methods. The automated measurement procedures minimize the liability for errors. All elements are detectable. Results can be quantified after calibration. At BAM LIBS has been successfully applied for the investigation of distribution and transport of different ions in building materials. Quantitative measurements are performed for chlorine, sodium, potassium, sulfur, lithium and hydrogen. In addition the identification of substances and the evaluation of quantitative ratios by means of an integrated marker are possible. An overview about the principle and the possibilities of LIBS investigations of building materials is presented and typical applications are shown. The LIBS technique is close to practical application on-site.
Laser Induced Breakdown Spectrocsopy (LIBS) - Visualizaton of Ion Transport Processes in Concrete
(2014)
Periodic mapping of reinforcement corrosion in intrusive chloride contaminated concrete with GPR
(2014)
This paper presents an experimental effort for developing a novel reinforcement corrosion monitoring technique based on Ground Penetrating Radar (GPR). Experiments were carried out to periodically monitor the accelerated reinforcement corrosion process with GPR. The data were processed in both time and timefrequency domains to investigate the tendencies of GPR signal attribute changes related with corrosion, moisture and chloride contamination. Data processing methods were proposed to visualize the reinforcement corrosion and chloride distribution with target specified signal attribute mapping. Half-Cell Potential (HCP) and Laser-Induced Breakdown Spectroscopy (LIBS) methods were employed to verify the GPR observations.
The accuracy and precision of low-frequency (center frequency of approximately 55 kHz) ultrasonic testing for detection and characterization of delamination in concrete bridge decks were evaluated. A multiprobe ultrasonic testing system (with horizontally polarized shear-wave transducers) was used to detect built-in delamination defects of various size, depth, and severity (i.e., thickness) in a test specimen—a 6.1 m × 2.4 m × 216 mm (20 ft × 8 ft × 8.5 in.) reinforced concrete slab-built to simulate a concrete bridge deck. The collected data sets were reconstructed applying synthetic aperture focusing technique (SAFT). The reconstructed measurement results were then used to assess the condition of the concrete slab at individual points [point-by-point data collection and two-dimensional (2D) reconstruction] as well as along lines, where data were collected at smaller steps and reconstructed in a three-dimensional (3D) format. The local-phase information was also calculated, superimposed on the reconstructed images and used as complementary information in condition assessment. The precision and accuracy of condition assessments were evaluated. The results indicated that, using the multiprobe ultrasonic array, delamination defects as small as 30 cm² (1 ft²) could be reliably detected. Deep delaminations [i.e., those deeper than 150 mm (6 in.)] were directly detected and characterized, whereas shallow delaminations [shallower than 65 mm (2.5 in.)] were detected only indirectly. The precision of the measurements was demonstrated by comparing repeated measurements at several test points. Similar measurement results obtained on a delaminated portion of a real bridge deck support the conclusions of the validation study.