Reliable standards are required to support research and development as well as end-user in application. Appropriate standards have to fulfill three requirements: small uncertainty, easy to use and low overall costs of application. For calibration of microscopes at nanoscale and/or element analysis special requirements for standards are given, which are challenging in manufacture.
A central challenge to ensure the sustainable production and use of nanotechnologies is to understand the risks for environment, health and safety associated with this technology and resulting materials and products, and to identify and implement practical strategies to minimize these risks. Knowledge about nanotechnology-enabled processes and products and related environment, health and safety issues is growing rapidly, achieved through numerous European or national R&D programs over the last decade, but effective use of this knowledge for risk management by market actors is lagging behind.
The EC4SafeNano initiative (www.EC4SafeNano.eu) is an ongoing effort to build a European Centre for Risk Management and Safe Innovation in Nanomaterials and Nanotechnologies. EC4SafeNano aims to bridge the gap between scientific knowledge on hazard and risk, and ‘fit-for-purpose’ risk management tools and strategies supported by measurement and control methods. The consortium comprises 15 partners (INERIS (coordinator), EU-VRi, TNO, BAM, FIOH, VITO, SP, DEMOKRITOS, TECNALIA, Health and Safety Executive, NRCWE, Paris Lodron University Salzburg, Université Libre de Bruxelles, University of Birmingham and ENEA) from 11 European Member States with significant expertise on risk assessment and management, who already provide knowledge and technical services to public and private organizations, to industry and to public authorities and regulatory bodies.
The overall objective of the EC4SafeNano project is to develop a distributed Centre of European Organisations offering services for Risk Management and Safe Innovation for Nanomaterials & Nanotechnologies. The Centre will be structured as a hub-based network of organizations managed by a core group of public-oriented bodies providing risk management and safe innovation support to all stakeholders. It will be operated with the support of Associated Partners so as to expand its capabilities, resources and services. It will interact with existing platforms and centres of excellence in nanosafety and foster the organization or development of national hubs mirroring the European hub. The Centre will seek financial support from stakeholders and service users to sustain the services in the longer term.
The operational objectives of the project involve understanding and mapping the needs of the various stakeholders (private and public). It will identify the resources and capabilities and develop a range of harmonized services required to meet these needs. The construction of the centre will include putting in place and implementing processes to deliver and update services, to test and benchmark services, to evaluate the governance of the Centre, and developing a business plan to ensure self-sufficiency of the Centre beyond the project lifetime.
A cornerstone of the project is to build a community for risk management and safe innovation for nanotechnology. Interested persons or organisations are invited to join this initiative as registered stakeholders or Associated Partners, to engage in focus networks and to help shape the future Centre. The poster will present the EC4SafeNano initiative and will detail the role of registered stakeholders and Associated Partners.
Graphene prepared from Graphene oxide (GO) is used as a platform for functional 2D nanomaterials with diverse applications ranging from bios ensors to antimicrobial surfaces. C and N K-edge NEXAFS and XPS spectroscopies at BESSY’s HE-SGM beamline have been used to prove and control covalent functionalization of graphenic materials at ambient conditions for the synthesis of functional 2D-surfaces.
The certified reference material BAM-L200, a nanoscale stripe pattern for length calibration and specification of lateral resolution, is described. BAM-L200 is prepared from a cross-sectioned epitaxially grown layer stack of AlxGa1-xAs and InxGa1-xAs on a GaAs substrate. The surface of BAM-L200 provides a flat pattern with stripe widths ranging down to 1 nm. Calibration distances, grating periods and stripe widths have been certified by TEM with traceability to the length unit. The combination of gratings, isolated narrow stripes and sharp edges of wide stripes offers a plenty of options for the determination of lateral resolution, sharpness and calibration of length scale at selected settings of imaging surface analytical instruments. The feasibility of the reference material for an analysis of the lateral resolution is demonstrated in detail by evaluation of ToF-SIMS, AES and EDX images. Other applications developed in the community are summarized, too.
BAM-L200 fully supports the implementation of the revised International Standard ISO 18516 (in preparation) which is based on knowledge outlined in the Technical Report ISO/TR 19319:2013. Fundamental approaches to determination of lateral resolution and sharpness in beam-based methods
Deuterium permeation and cracking in duplex steels as viewed by ToF-SIMS and HR-SEM with data fusion
(2016)
Better understanding of hydrogen assisted degradation and trapping mecha-nisms requires sufficient imaging techniques for respective hydrogen-microstructure interaction studies, in particular with multi-phase metallic micro-structures [1]. The present work is focusing on the elucidation of deuterium be-havior in two austenitic-ferritic duplex stainless steels (DSS) under the assumption that deuterium behaves in many ways similarly to hydrogen [2]. For case studies standard 2205 and lean 2101 DSSs were chosen due to the extensive use of these steels in industry [3]. The analyses were conducted by using a novel in-situ permeation and Time-of-Flight secondary ion mass spectrometry (ToF-SIMS) imaging technique or by ex-situ ToF-SIMS imaging following electrochemical charging experiments. Another pioneering procedure was data fusion (including chemometry) of results of powerful laterally resolved chemical analysis and high resolution structural characterization techniques .
Results for the ex-situ observations showed a different influence of deuterium loading on the two steel grades as well as different damage mechanisms in each phase. Formation of sub-surface blisters between the ferrite and austenite were obtained in both the standard and the lean DSS. In both steels, an increased deuterium concentration was observed around deformed regions such as cracks, confirming that they originate from the presence of deuterium [4]. The formation of parallel cracks was obtained only in the austenite within the standard duplex whereas in the lean duplex the highest intensity of deuterium was obtained in the austenite along the ferrite-austenite interphase.
In comparison, application of the novel in-situ permeation technique enabled to register and record the deuterium permeation through the material and the respective saturation sequence of the two phases as well as the interfaces. Faster diffusion of the deuterium was observed in the ferrite and a direct proof for deuterium enrichment at the austenite-ferrite interface has been given [1]. The integration of the specified techniques gives a better insight into the processes leading to hydrogen induced failure. These two experimental techniques provide very valuable tools for elucidation of respective metallurgical failure mechanisms that can be used for the validation of respective numerical models for hydrogen assisted cracking (HAC).