Filtern
Erscheinungsjahr
- 2012 (27) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (20)
- Vortrag (6)
- Posterpräsentation (1)
Schlagworte
- Fluorescence (7)
- Photoluminescence (5)
- Quantum yield (4)
- Dye (3)
- Method comparison (3)
- Uncertainty (3)
- Absolute quantum yield (2)
- Aggregation (2)
- Cyanine (2)
- DNA (2)
Eingeladener Vortrag
- nein (6)
Photoluminescence techniques are amongst the most widely used tools in the material and life sciences, with new and exciting applications continuously emerging. Advantages include their comparative ease of use, unique sensitivity, non-invasive character, and potential for multiplexing, remote sensing, and miniaturization. Increasing applications of fluorescence techniques in the life sciences and emerging medical applications of fluorescence microscopic techniques including 1P and 2P fluorescence microscopy combined with fluorescence lifetime imaging (FLIM) in e.g. in vivo eye diagnostics boosted the demand for robust, easy-to-use, and reliable fluorescence standards to ensure the reliability and comparability of fluorescence data. This includes fluorescence standards for the consideration of instrument-specific spectral and intensity distortions of measured signals and instrument performance validation, fluorescence intensity standards for the quantification of measured intensities and for signal referencing, and lately, also fluorescence lifetime standards.
We systematically assessed the loading behavior of core-multishell nanoparticles (CMS NPs) for the solvatochromic dyes Coumarin 153 and Nile Red and studied the influence of the guest and its concentration on CMS NP aggregation using steady state absorption and fluorescence spectroscopy and dynamic light scattering (DLS). These measurements revealed the strong fluorescence of dye-loaded CMS NPs and formation of nonemissive dye aggregates in the outer CMS layer at higher loading concentrations of Nile Red, whereas in the case of Coumarin 153, a new species with red-shifted absorption and blue-shifted emission appeared. Moreover, dye loading triggers an aggregation of CMS NPs which have a hydrodynamic radius of 8 nm, thereby leading to CMS aggregates with a radius of 100–120 nm. These results underline the need for systematic studies of the influence of the guest and its loading concentration on CMS NP size for cellular uptake and in vivo imaging studies and the rational design of CMS NPs with improved transport and targeting abilities.
Image-guided, targeted and triggered drug delivery to tumors using polymer-based microbubbles
(2012)
Microbubbles (MB) are routinely used contrast agents for functional and molecular ultrasound (US) imaging. In addition, they have been attracting more and more attention for drug delivery purposes, enabling e.g. US-mediated drug delivery across biological barriers and US-induced triggered drug release from the MB shell. The vast majority of efforts in this regard have thus far focused on phospholipid-based soft-shell MB, which are suboptimal for stably incorporating large amounts of drug molecules because of their relatively thin shell. Using poly(butyl cyanoacrylate) (PBCA)-based hard-shell MB, we show here that both hydrophilic (Rhodamine-B) and hydrophobic (Coumarin-6) model drugs can be efficiently and stably entrapped within the ~ 50 nm shell of PBCA MB. In addition, we demonstrate that model drug loading does not negatively affect the acoustic properties of the MB, and that functionalizing the surface of fluorophore-loaded MB with anti-VEGFR2 antibodies enables image-guided and targeted model drug delivery to tumor blood vessels. Finally, we show both in vitro and in vivo that disintegrating VEGFR2-targeted MB with high-mechanical index US pulses leads to high levels of model drug release. Consequently, these findings indicate that polymer-based MB are highly suitable systems for image-guided, targeted and triggered drug delivery to tumors and tumor blood vessels.
In the second part of this two-part series on the state-of-the-art comparability of corrected emission spectra, we have extended this assessment to the broader community of fluorescence spectroscopists by involving 12 field laboratories that were randomly selected on the basis of their fluorescence measuring equipment. These laboratories performed a reference material (RM)-based fluorometer calibration with commercially available spectral fluorescence standards following a standard operating procedure that involved routine measurement conditions and the data evaluation software LINKCORR developed and provided by the Federal Institute for Materials Research and Testing (BAM). This instrument-specific emission correction curve was subsequently used for the determination of the corrected emission spectra of three test dyes, X, QS, and Y, revealing an average accuracy of 6.8% for the corrected emission spectra. This compares well with the relative standard uncertainties of 4.2% for physical standard-based spectral corrections demonstrated in the first part of this study (previous paper in this issue) involving an international group of four expert laboratories. The excellent comparability of the measurements of the field laboratories also demonstrates the effectiveness of RM-based correction procedures.
Efficient signal generation in DNA-based assays requires understanding of the influence of fluorophores interactions on the spectroscopic properties. The resulting changes in fluorescence intensity, quantum yield, emission anisotropy, and fluorescence lifetime provide straightforward tools for the study of molecular dynamics and interaction between labels and nucleic acids. Searching for bright fluorescent reporters for rolling circle amplification (RCA) as efficient signal enhancement strategy for biological formats, we investigated the spectroscopic properties of seven dyes: cyanines, rhodamines, and BODIPYs. They spectrally resemble Cy3, the most frequently used fluorophore in biodetection formats, and are measured in six samples (free dye, dye-dUTP, internally labeled ssDNA and dsDNA—single- and triple-labeled) using steady-state and time-resolved fluorometry. Special emphasis was dedicated to characterizing the nature of the interaction of these fluorophores differing in dye class, charge, and rigidity. Our results suggest dye charge and structure as main factors governing the dyes interactions, with DY-555 and Cy3B presenting the best candidates for our envisaged signal amplification strategy. This label comparison underlines the importance of a proper understanding of structure-property relations and dyebiomolecule interactions for reporter choice and presents a road map towards the design and interpretation of experiments using these labels on DNA of known sequence.