Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (53)
Referierte Publikation
- nein (53)
Schlagworte
- Simulation (53) (entfernen)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (17)
- 8.4 Akustische und elektromagnetische Verfahren (12)
- 6 Materialchemie (5)
- 8.5 Röntgenbildgebung (4)
- 3 Gefahrgutumschließungen; Energiespeicher (3)
- 6.6 Physik und chemische Analytik der Polymere (3)
- 7 Bauwerkssicherheit (3)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (2)
- 7.7 Modellierung und Simulation (2)
- 3.0 Abteilungsleitung und andere (1)
Eingeladener Vortrag
- nein (53) (entfernen)
Virtual CT acquisition and reconstruction of complex and noisy scanning trajectories in aRTist
(2019)
In modern CT imaging, simulation has become an important tool to minimize cost- and time-intensive measurements. It is increasingly used to optimize techniques for complex applications, to support the preparation of written procedures, and for educational purposes. We extended the CT simulation software ‘aRTist’ with a module to set-up arbitrary trajectories including disturbing influences during the scan. Moreover, such geometric deviations can be compensated by the internal reconstruction tool.
The project series CTSimU was initiated with the goal to develop a set of procedures to enable the determination of the task-specific measurement uncertainty of a CT system numerically by radiographic simulation. The first project (2019-2022) “Radiographic Computed Tomography Simulation for Measurement Uncertainty Evaluation - CTSimU” was focused on the sufficient physical correctness of the radiographic simulation and created as a result a test framework for simulation softwares and a draft of a VDI standard in the series VDI/VDE 2630 for this application. However, for the realistic simulation of a CT system in a simulation software (i.e. a digital twin), not only the correctness of the simulation software itself is crucial, but also the quality of the parameterization of the CT system in the simulation software - this represents the starting point of the 2nd project “Realistic Simulation of real CT systems with a basic-qualified Simulation Software - CTSimU2” (2022-2024).
The parameterization of a CT system in a simulation software can be divided into four steps: after the data acquisition at the real CT system (step 1) follows the evaluation of the acquired data for the generation of general parameter specifications (step 2). It follows the transfer of the parameters into the specific simulation software (step 3) and the validation of the resulting simulation parameters by a suitable test (step 4). The intended result of the project CTSimU2 is a draft VDI standard (for VDI/VDE 2630) for this test, which contains an informative annex on the state of the art regarding the possibilities for parameter determination.
Ein neuartiger Modellierungsansatz für die Berechnung des transienten Temperaturfeldes beim Laserstrahlschweißen mit einer äquivalenten Wärmequelle wurde vorgestellt. Das numerische Modell wurde in zwei Studien unterteilt. Im ersten Teil wurde der Laserstrahlschweißprozess in einer stationären Schmelzbadsimulation untersucht. Die lokale Schmelzbadgeometrie und das Temperaturfeld wurden unter Berücksichtigung der Effekte der thermokapillaren und freien Konvektion, der latenten Wärme und der temperaturabhängigen Materialeigenschaften bis hin zur Verdampfungstemperatur ermittelt. Die Ergebnisse wurden benutzt, um eine äquivalente volumetrische Wärmequelle zu definieren. In der folgenden Studie wurde damit das transiente Temperaturfeld im geschweißten Bauteil berechnet. Die numerischen Ergebnisse wurden durch parallel laufende Experimente validiert.