Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (20027) (entfernen)
Sprache
- Deutsch (13140)
- Englisch (6836)
- Mehrsprachig (24)
- Spanisch (13)
- Französisch (9)
- Russisch (3)
- Tschechisch (1)
- Ungarisch (1)
Referierte Publikation
- nein (20027)
Schlagworte
- Korrosion (254)
- Corrosion (141)
- Additive manufacturing (126)
- Additive Manufacturing (123)
- Additive Fertigung (115)
- Concrete (108)
- Hydrogen (106)
- Nanoparticles (96)
- LIBS (92)
- Wasserstoff (84)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (941)
- 6 Materialchemie (850)
- 7 Bauwerkssicherheit (833)
- 9 Komponentensicherheit (756)
- 1 Analytische Chemie; Referenzmaterialien (586)
- 5 Werkstofftechnik (470)
- 4 Material und Umwelt (443)
- 3 Gefahrgutumschließungen; Energiespeicher (431)
- 7.6 Korrosion und Korrosionsschutz (360)
- 9.4 Integrität von Schweißverbindungen (360)
Monitoring von Mikroplastik
(2021)
Results from different methods applied to micro- and nanoplastics (MNPs) analysis show that there are large gaps in harmonisation with respect to terminology, size classes, sample preparation protocols and, finally, to the comparability of the measurands and descriptors.
Within the European research cluster to understand the health impacts of micro- and nanoplastics (CUSP) working group WG3-Inter-Laboratory Comparisons an overview of the existing detection methods revealing advantages and disadvantages regarding the analytical tasks is being compiled. There is a clear need to develop high class characterized reference materials for MNPs in the size ranges of 100-10 µm and smaller than 10 µm, so that these can be used to validate methods and to make results comparable. Inter-laboratory comparisons (ILCs) on model samples with complex matrices regarding mass, or water samples for number-based methods, will help us to advance the process of harmonization as well as to train users early in process of developing new methods.
We plan to keep all five CUSP projects well-connected also with the 'outside' MNP projects and ILCs and to extract the optimum of needs, capabilities, and efforts in order to launch new VAMAS ILCs which should expand already available ones.
In this breakout session first, an introduction is given on the planning and organisation of an inter-laboratory comparison (ILC) under the pre-standardisation plattform VAMAS within the newly formed technical working area TWA 45 Micro and Nano Plastics in the Environment. An update with the ILCs on micro- and nanoplastic performed so far is also given. In the third part, the requirements for a reference materials are presented. The needs from the different H2020 micro- and nanoplastic projects are collected and compiled in an ILC matrix for joint activities as the next steps.
Microbiologically influenced corrosion (MIC) is a highly unpredictable process involving a complex group of microorganisms, including sulfate-reducing bacteria and methanogens. Standard laboratory MIC testing using static serum bottle enrichments is an easy but limited method, offering poor resolution on the biomineralization process of corrosion products. An example of this is the presumed corrosion product siderite by corrosive methanogens (Mi-MIC). Previous publications reported siderite was the sole corrosion product of M. maripaludis using metal coupons incubated under stationary conditions.
However, the formation of siderite is closely related to the surrounding environmental conditions, i.e. pH, CO2 concentration, flow and temperature. Thus, siderite as the sole corrosion product of Mi-MIC remain inconclusive and questionable. To study Mi-MIC effectively, a novel versatile multiport flow-column corrosion monitoring system (MFC) was developed. MFC allows sectional corrosion rate determination under flow conditions using different types of material, inoculum and packing material. MFC offers great flexibility, ease of operation and accurate corrosion measurements that can be combined with many other techniques. Using MFC, we studied multiple strains of methanogens and compared it with sulfate-reducing bacteria under neutral and low pH conditions. It was revealed by MFC that corrosive methanogens have equally high corrosion potential as sulfate-reducing bacteria. Additionally, siderite is not the dominant nor sole corrosion product of Mi-MIC. Thus, effective corrosion monitoring and establishing standard laboratory practices, i.e. incorporating MFC as part of regular testing process, will provide deeper understanding of MIC. This will allow further microbial electrophysiology understandings, contributing to effective mitigation strategy development.
Biocide mitigation strategies of microbiologically influenced corrosion (MIC) in the oil and gas industry have been primarily used to eliminate the growths of sulfate-reducing microorganisms (SRM). However, methanogenic Archaea (MA) can also be highly corrosive by using iron as an electron source for methanogenesis. Because of the fundamental physiological differences between archaea and bacteria, responses of MA towards SRM-specific biocides cannot be deduced using SRM. Due to the lack of information available on the effect of biocides on corrosive MA, we selected THPS, glutaraldehyde, nitrate and perchlorate to compare against corrosive SRM.
Preliminary results showed that at low concentrations of THPS (0-10 ppm), growth of MA was not affected, methane production and corrosion rates (0.1 mm/yr) were comparable between the different THPS concentrations. On the contrary, the SRM strain showed decreased corrosion rates (0.18 mm/yr to 0.03 mm/yr) with increasing THPS concentrations. Further corrosion tests including electrochemical measurements of different biocides on the growth of MA and SRM will be conducted. Such knowledge not only provide important insights on the physiological response of MA to biocides but also contribute to more effective mitigation strategies that can be both economic and environmentally beneficial.
Microbiologically influenced corrosion (MIC) is an expensive but unpredictable problem for the industries. The most well-known culprit for MIC is the sulfate-reducing microorganisms (SRM), such as members from the genus Desulfovibrio. It has been widely accepted that SRM can contribute significantly to MIC through the production of hydrogen sulfide (HS-) or in some cases a direct electron uptake from the metal surface. However, in a real environmental system, SRM is not exclusive and often involved with other microorganisms that may also contribute to MIC, such as methanogens.
Methanogenic archaea can produce methane (CH4) using H2+CO2, formate, methylated amines or acetate. Methanogens are highly abundant in the environment and many are found in very extreme conditions, such as high temperature and high salinity. Previous researches have demonstrated that methanogens are capable of MIC, though the specific mechanisms are still under investigation. In the oil and gas industry, methanogens are not considered as the main contributor for MIC since the corrosion rates are often too low. However, the tests for methanogen-induced MIC are usually performed at static conditions, which cannot represent the system accurately. Here, we developed a novel anaerobic system to evaluate the corrosion potential of methanogens under flow conditions. We will use the Methanococcus maripaludis KA1 strain, which was isolated from a crude oil tank, as the organism of interest. A separate system for Desulfovibrio alaskensis will be established for corrosion rate comparisons. Furthermore, we will study the synergistic effects of M. maripaludis and D. alaskensis on MIC under flow.
In recent years, the use of simulation-based digital twins for monitoring and assessment of complex mechanical systems has greatly expanded. Their potential to increase the information obtained from limited data makes them an invaluable tool for a broad range of real-world applications. Nonetheless, there usually exists a discrepancy between the predicted response and the measurements of the system once built. One of the main contributors to this difference in addition to miscalibrated model parameters is the model error. Quantifying this socalled model bias (as well as proper values for the model parameters) is critical for the reliable performance of digital twins. Model bias identification is ultimately an inverse problem where information from measurements is used to update the original model. Bayesian formulations can tackle this task. Including the model bias as a parameter to be inferred enables the use of a Bayesian framework to obtain a probability distribution that represents the uncertainty between the measurements and the model. Simultaneously, this procedure can be combined with a classic parameter updating scheme to account for the trainable parameters in the original model. This study evaluates the effectiveness of different model bias identification approaches based on Bayesian inference methods. This includes more classical approaches such as direct parameter estimation using MCMC in a Bayesian setup, as well as more recent proposals such as stat- FEM or orthogonal Gaussian Processes. Their potential use in digital twins, generalization capabilities, and computational cost is extensively analyzed.
NIR-excitable lanthanide nanocrystals (LnNC) show multi-color emission pattern composed of a multitude of narrow bands of varying intensity in the ultraviolet, visible, near-infrared, and short-wave infrared detectable with miniaturized optical instruments and simple color (RGB) cameras in complex environments. This makes these chemically inert luminescent materials ideal candidates for anticounterfeiting and authentication applications as well as for modules in optical sensors in which the LnNCs can be used as nanolamps in combination with analyte-sensitive fluorophores or the temperature sensitivity of defined emission bands can be utilized.
Therefore, we are building up and exploring a platform of LnNC with application-specifically tuned size, composition, and surface chemistry.
Assessing dissolution of upconverting nanoparticles by TEM, EDXS, potentiometry and fluorometry
(2021)
Inorganic lanthanide-doped upconversion nanoparticles (UCNP) constitute an emerging class of near-infrared (NIR)-excitable luminescent reporters for bioimaging, fluorescence assays, sensors in bioanalysis, and optical thermometry as well as phosphors for photovoltaic and security applications.1 However, the use of UCNPs in bioimaging and cellular studies requires biocompatible particles. One possible cause of UCNP toxicity is the release of potentially harmful fluoride fluoride and lanthanide ions as revealed by dilution studies in aqueous environments, particularly under high dilution conditions.2-5 To address this issue, suitable surface coatings preventing such effects in combination with fast screening methods suited for online in situ analysis are desired.
Here we present a systematic study of differently sized β-NaYF4:Yb,Er nanocrystals stabilized with different surface coatings and different hydrophilic ligands varying in binding strength to the surface atoms in various aqueous environments at different temperatures.
Simulation-based digital twins have emerged as a powerful tool for evaluating the mechanical response of bridges. As virtual representations of physical systems, digital twins can provide a wealth of information that complements traditional inspection and monitoring data. By incorporating virtual sensors and predictive maintenance strategies, they have the potential to improve our understanding of the behavior and performance of bridges over time. However, as bridges age and undergo regular loading and extreme events, their structural characteristics change, often differing from the predictions of their initial design. Digital twins must be continuously adapted to reflect these changes. In this article, we present a Bayesian framework for updating simulation-based digital twins in the context of bridges. Our approach integrates information from measurements to account for inaccuracies in the simulation model and quantify uncertainties. Through its implementation and assessment, this work demonstrates the potential for digital twins to provide a reliable and up-to-date representation of bridge behavior, helping to inform decision-making for maintenance and management.
Niobium metal is the pure element with the highest superconducting critical temperature (T_c = 9.2 K), which is present in many applications. Particularly, in superconducting radio frequency (SRF) cavities of particle accelerators, the control of the surface characteristics of pure Nb is crucial, as the presence of defects may generate magnetic flux pinning that can increase by more than two orders of magnitude the surface critical current, ic. Several procedures such as chemical- or electro-polishing have been used aiming at cleaning surface contamination and decreasing its roughness. Sub-nanosecond lasers can be applied to generate a broad range of micro and nanostructures (e.g. Laser-Induced Periodic Surface Structures, LIPSS) that strongly modify the materials properties - as wettability, color, oxidation resistance or antibacterial behavior. In this work, we analyze a variety of surface structures generated on pure Nb sheets with different laser systems (UV, Vis and n-IR, fs and ps) by exploring a range of processing parameters. These include pulse overlap, irradiance or the effective number of pulses, under different atmospheres (air, N2, Ar, vacuum). The effects on Tc, critical currents and critical fields (Bc1, Bc2 and Bc3) have been obtained from magnetization, ac susceptibility and heat capacity measurements, revealing their dependence with the different surface nanostructures and the chemical changes generated with these laser treatments.
Die BAM ist als Benannte Stelle im Rahmen der europäischen
Richtlinien 97/23/EG über Druckgeräte (PED) [1] und
1999/36/EG über ortsbewegliche Druckgeräte (TPED) [2] bei
der Zertifizierung von Ausrüstungsteilen für Druckgefäße (PED
und TPED), Baugruppen (PED) und der Neubewertung von
Baumustern (TPED) tätig. In diesem Beitrag wird die Zertifizierung
einschließlich der dabei gewonnenen Erfahrungen
und in der Praxis auftretenden Problemen auf Seiten der
Hersteller und Benannten Stellen bei der Zertifizierung nach
diesen europäischen Richtlinien vorgestellt. Die wesentlichen
Probleme ergeben sich aus der Zuordnung der Druckgeräte
zu entsprechenden Kategorien innerhalb der Richtlinien und
aus der Überschneidung mit anderen europäischen und
nationalen Richtlinien.
Die neue Europäische Richtlinie über ortsbewegliche Druckgeräte - Was kommt, was geht, was bleibt?
(2010)
Im Vortrag wird auf die rechtlichen Grundlagen der Richtlinie 2010/35/EU eingegangen. Dies umfasst die Definition von ortsbeweglichen Druckgeräten, die an sie gestellten technischen Anforderungen und die Anforderungen an deren Konformitätsbewertung. Des Weiteren wird die Anwendung der Richtlinie auf Feuerlöscher und deren Treibgasflaschen diskutiert
Im Vortrag wird auf die aktuellen Anforderungen aus dem Gefahrgutbeförderungsrecht an Ventilschutz einschließlich Schutzkragen als integraler Bestandteil einiger Gasflaschen und LPG-Sicherheitsventilen eingegangen. Des Weiteren werden die aktuell laufenden Revisionen der Normen EN ISO 11117 für Ventilschutz und EN 13953 für LPG-Sicherheitsventile diskutiert.
Im Vortrag wird auf die rechtlichen Grundlagen der Richtlinie 2010/35/EU eingegangen. Dies umfasst die Definition von ortsbeweglichen Druckgeräten, die an sie gestellten technischen Anforderungen und die Anforderungen an deren Konformitätsbewertung. Des Weiteren wird die Anwendung der Richtlinie auf Feuerlöscher und deren Treibgasflaschen sowie die damit verbundenen Probleme in der Praxis diskutiert.
Im Vortrag wird auf die rechtlichen Grundlagen der Richtlinie 2010/35/EU eingegangen. Dies umfasst die Definition von ortsbeweglichen Druckgeräten, die an sie gestellten technischen Anforderungen und die Anforderungen an deren Konformitätsbewertung. Des Weiteren wird die Anwendung der Richtlinie auf Feuerlöscher und deren Treibgasflaschen sowie die damit verbundenen Probleme in der Praxis diskutiert.
Geothermal brine is considered to be an aggressive
environment as it contains various dissolved salts.
Even though carbon steel is commonly used as a
construction material due to its machinability and
economical reason, it is susceptible to uniform and
localized corrosion in a high temperature and high
pressure system. Therefore, a coating system is
introduced to protect the carbon steel against
corrosion in such environment.
1. Carbon steel is susceptible to uniform corrosion in presence of oxygen, with corrosion rate of immersion at 150 °C of 0.39 mm/a.
2. Exposure test of carbon steel at 150°C and 10 bar (pressurized by Ar) results in pitting corrosion with depth of 19 µm and width 4 µm on average.
3. OCP measurement shows that the stability of measurement is reached after 40 hours of immersion in the solution.
4. EIS measurement is useful to observe the effect of temperature, immersion time, and coating composition on the corrosion processes of coated metals for use in geothermal application.
Geothermal brine is a complex system containing a wide variety of dissolved salts resulting from the condition s in a geothermal well. These fluids lead to corrosion in pipes and other parts of geothermal system construction and necessitate intense research efforts in finding new suitable materials. Carbon steel is susceptible to corrosion in geothermal brine especially when it is exposed to a high temperature and high-pressure medium, which is considered to be an aggressive environment. An artificial geothermal water, bas ed on a brine composition found in Indonesia, was used to investigate the performance of high alloyed materials. The electrolyte has pH 4 and contains 1,500 mg/l Cl-, 20 mg/l SO4 2-, 15 mg/l HCO3 -, 200 mg/l Ca 2+, 250 mg/l K+, and 600 mg/l Na+. In order to protect the bare material in geothermal application, it is necessary to either use high alloyed material s or coatings. In this research, a coating system consisting of polyaniline and silicon dioxide was investigated regarding its behavior to protect carbon steel. In detail, the effect of SiO2 and polyaniline (PANi) addition was evaluated by exposure and electrochemical tests for 7 days, i.e. electrochemical impedance spectroscopy (EIS) and open circuit potential (OCP) at room temperature and 150 °C with 1 MPa pressure.