Ammonia Safety
(2023)
Ammonia is an energy source that has been produced and used on a large scale for many decades, primarily as a fertilizer or feedstock in nitrogen chemistry. The CAMPFIRE alliance, founded as part of the "WIR!- Wandel durch Innovation in der Region" funding program of the German Federal Ministry of Education and Research (BMBF), aims to research and develop new energy conversion and storage technologies for the future energy system based on green ammonia. The safe handling of ammonia is an important issue along the entire value chain. Therefore, the alliance has organized a webinar to discuss the topic of ammonia safety and in particular its flammability. BAM's contribution presented the topic of flammability in detail, placed the classification of ammonia in an international, European and national context and presented the basic principles of explosion protection that result from this and must be observed during use and application.
Polyamide 4.6 (PA46) is a high-heat-resistant polymer, but it has no dripping resistance under fire. Three commercial grades of PA46 are investigated under UL 94 vertical fire test conditions. Their performances are discussed based on the materials’ structural, thermal, and rheological properties. PA46 presents flaming drops, whereas dripping is prevented in the flame-retarded PA46.
Friction-modified PA46 has increased flaming dripping. Temperature profiles of the specimens under fire and the temperature of the drops are measured by thermocouples. A UL 94 vertical test configuration consisting of two flame applications is designed to assess the quantitative dripping behavior of the set of materials by the particle finite element method (PFEM). Polymer properties (activation energy and Arrhenius coefficient of decomposition, char yield, density, effective heat of combustion, heat of decomposition, specific heat capacity, and thermal conductivity) in addition to rheological responses in high temperatures are estimated and measured as input parameters for the simulations. The dripping behavior obtained by simulated materials corresponds with the experimental results in terms of time and drop size. A consistent picture of the interplay of the different phenomena controlling dripping under fire appears to deliver a better understanding of the role of different materials’ properties
Only the nano-scaled structure of the nanocomposite and the dispersion of nanoparticles within the polymer matrix harbor multifunctional potential including superior fire retardancy. Thus, this chapter focuses on the dispersion of nanoplates, based mainly on studies of layered silicates and graphene/graphene-related nanoplates. The nanostructure and properties of the nanocomposites are dependent mainly on thermodynamic and kinetic factors during preparation. Improving nano-dispersion often directly improves flame retardancy. Therefore, the modification of the nanoplates as well as the preparation of nanocomposites becomes very important to control this dispersion. The dispersion of nanoplates functions as a prerequisite for the formation of an efficient protective layer, changing the melt flow and dripping behavior, or the improvement of the char properties.
Fire resistance of fiber-reinforced polymers (FRPs) has been an important area of research for many years since FRPs are mainly used in the transportation and construction sectors. This study presents the fire behavior, and mechanical performance between the flame retarded pure epoxy resin and flame retarded glass-fiber composites before, during, and after a fire event. This enables a deeper understanding of the transferability of flame retardants on composite materials.
The influence of pressure sensitive adhesive (PSA) tapes as adhesive layers on the burning behaviour of bonded materials has been investigated. Single-sided tapes as an outer connection between construction materials have large influence on flammability, flame spread and fire resistance. In contrast, double sided tapes only take a small impact on the flammability but can drasticly change the burning behaviour in developing fires.
In this study, experimental determination and modelling investigations for the explosion regions of 1,3-dioxolane/inert gas/N2O and 1,3-dioxolane/inert gas/air mixtures were carried out and compared. The experimental measurements were carried out at 338 K and atmospheric pressure according to EN1839 method T using the inert gases N2, CO2, He and Ar. The results showed that the ratio of the lower explosion limit in N2O (LELN2O) to the lower explosion limit in air (LELair) is 0.52 and the ratio of the maximum oxygen content in air (MOCair) to the limiting oxidizer fraction in nitrous oxide (LOFN2O) is 0.36 ± 0.02 independent of the inert gas. When comparing the inert gas amount at the apex based on the pure oxidizing component, which is O2 in case of air, N2O-containing mixtures need less inert gas to reach the limiting oxidizer quantity whereas the efficiency of inert gases is in the same order. The coefficients of nitrogen equivalency however were found to differ to some extent. The explosion regions of 1,3-dioxolane/inert gas/oxidizer mixtures were modelled using the calculated adiabatic flame temperature profile (CAFTP) method as well as corrected adiabatic flame temperatures. The results indicate good agreement with experimental data for CO2, N2 and Ar- containing mixtures. The noticeable deviations that occur when He is the inert gas are due to the lacking transport data of that mixture.
Polyurethanes (PU) represent one of the most versatile classes of plastics. They are processed and used as thermoplastic, elastomer, and thermoset. The requirements regarding flammability are correspondingly versatile. Depending on the material and the field of application, specific fire tests have to be fulfilled. This paper describes the different concepts used to fulfil these requirements by choosing the right raw materials and flame retardants.
Flame retarded polymeric materials are used in various applications in which a certain fire behavior is demanded. Protection goals are defined, such as limited flammability in terms of hindered sustained ignition or limited contribution to a fire, and these protection levels are tested with defined specimens or components in defined fire scenarios, that is to say, different fire tests. Passing a specific fire test by meeting whatever its demands is often the most important development goal, so the parameters of the different fire tests vary widely to emphasize different fire properties. Some fire tests are used to screen or provide a general assessment of flame retardant polymers during development, while other fire tests and tailored experiments are performed to address special phenomena or understand the flame retardancy modes of action. For all fire testing, the devil is in the details – demanding know-how and crucial efforts to manage the quality of investigations and advanced interpretation. This chapter aims to offer a structured overview of all these aspects.
Most fluorinated hydrocarbons that shall replace refrigerants with high GWP, like R134a, are flammable. For evaluating inertization measures for explosion protection, flammability of low-GWP refrigerants R1234yf, R32 and R1132a blended with carbon dioxide, nitrogen and argon were studied experimentally in a closed autoclave at atmospheric conditions. Furthermore, a calculation method was adapted to reduce the experimental costs for flammability studies on these gas mixtures. For igniting R1234yf in the closed autoclave a newly developed ignition system was used that allows generating electric arcs with high ignition energy. Gas mixtures containing the mildly flammable R1234yf and R32 could be inerted by adding much less inert gas than mixtures containing R1132a, which is more similar to unfluorinated hydrocarbons regarding the explosion regions. By using the adapted model of constant adiabatic flame temperature profiles estimating the explosion limits of fluorinated hydrocarbons was possible with similar accuracy as for unfluorinated hydrocarbons.
Keywords: Explosion Protection, Inertization, Flammability, HFOs, HFC., R1234yf, R32, R1132a
The paper provides a summary of safety characteristics of hydrogen and hydrogen fuel gases. The inves-tigations focus on water electrolysis, the feeding of hydrogen into the natural gas grid and the use ofhydrogen for the fermentation process in biogas plants. The safety characteristics of hydrogen such as avery low minimum ignition energy, very large explosion range and high flame velocity with the resultingrapid pressure increase of hydrogen explosions are of particular importance for explosion protection andthey differ strongly from those of natural gas. Explosion ranges of hydrogen-methane-carbon dioxidemixtures have been measured for the use of hydrogen in biomethane production. The paper also showsand discusses explosion ranges of hydrogen and hydrogen-natural gas mixtures. Pressure and tempera-ture dependencies of the explosion limits of mixtures were investigated. Furthermore, pressure rise rates(KGvalues) were measured with regard to constructive explosion protection. The maximum experimen-tal safe gaps were determined for the classification of the mixtures and assignment to explosion groupsaccording to the European ATEX directives. It was found that admixture of 10% hydrogen to natural gashas only a minor influence on the safety characteristics of gas explosions.
Flame-retarded biocomposites of thermoplastic starch and natural fibres are successfully processed according to state-of-the-art extrusion and injection moulding. Using agave fibres and henequen fibres recovered from local industrial waste is a convincing contribution to sustainability. A systematically varied set of biocomposites is investigated comprehensively, e.g. electron microscopy is used for characterizing the morphology, rheology for the melt viscosity, tensile and impact resistance for the mechanical properties, thermal analysis for the pyrolysis, UL 94 burning chamber and oxygen index for the flammability, and cone calorimeter for the fire behaviour. Achieving sufficient mechanical properties was not the goal in our pre-competitive study but may be tackled by adding compatibilizer in future. The combination of well-dispersed natural fibres, aluminium diethylphosphinate (AlPi) and a special silicone synergist (Si) is proposed as promising innovative route for V-classified biocomposites. The flame-retardancy modes of action in the gas phase (fuel dilution and flame inhibition) and in the condensed phase (charring, protective layer formation) are discussed in detail, as is the role of combining the ingredients. This work is a convincing proof of principle of how to prepare industrial-waste fibres biocomposites, to apply the synergistic combination of AlPi and Si for future flame-retarded technical polymer materials that are based on renewable resources and compostable.
This paper is based mainly on the results of two different projects performed in the group of the author recently (2016-2019). The three external partners involved in these two projects are competent in the preparation of FPUF (ICL IP America), RPUF (Department of Industrial Engineering, Padova University), and TPU (Fraunhofer-Institut für Betriebsfestigkeit und Systemzuverlässigkeit LBF, Darmstadt) as well as for the specimen preparation. Systematically varied sets of materials were prepared as the key basic for scientific discussion, varying the kind and combination of flame retardant, PUR structure, density, and blowing agent.
A multimethodical approach based on thermogravimetry (TGA), TGA coupled with evolved gas analysis (TGA-FTIR) and pyrolysis GC-MS was used for investigating the pyrolysis. The flammability was addressed using oxygen index (OI) and testing in UL 94 burning chamber in vertical and horizontal set-up. The fire behaviour was addressed by using a cone calorimeter. Beyond these methods according to the state of the art, key experiments were performed. We addressed the dripping and the two-stage burning of TPU using a self-designed apparatus and specific data evaluation, the foam burning through quenching burning samples, using different special sample holders, and measuring temperature profiles within the burning foams. The investigation is made round by intensive analysis of the fire residues, such as comprehensive investigation of the morphology.
Result on the pyrolysis (TGA-FTIR, Pyrolysis-GC/MS), flammability (UL 94, LOI), and fire behaviour (cone calorimeter) of TPU and flame retardant TPUs are shown. We discuss in detail the characteristic of PUR decomposition: the low tendency to char, and the specific two step decomposition and how these characteristics control the regimes in fire behaviour. We demonstrate that the different burning regimes are controlled by different pyrolysis products and effective heat of combustions. The resulting formation of pool fires as well as the formation of dripping is discussed in detail. The latter quite important to understand the flame retardancy applied with respect to achieve the UL 94 classification V0 nondripping or V0 non-flaming dripping.
Rigid and flexible PUR foams and their flame retarded versions are investigated for different densities. Water and pentane-blown foams are compared as well as PUR and polyisocyanurate-polyurethane (PIR) foams. Horizontal testing in the cone calorimeter is used and the vertical foam specimen holder as well. Self-designed set-ups within the cone calorimeter enable a better inside in the pyrolysis front running through the foam samples as well as the development of the temperature gradient inside the foam during the fire test. The morphology change during burning was characterised by the means of quenching burning foams with liquid nitrogen and investigating the cross sections with scanning electron microscope. In sum, a rather comprehensive study was performed to work out the principle fire phenomena controlling the fire behaviour of PUR foams in a very systematic and significant way.
Promising flame retardancy approaches are discussed. The importance of either combining the drain of fuel and flame inhibition or charring into an effective protection layer/multicellular structure is underlined.
This contribution focusses the general conclusions and trends. It tries to increase the understanding of the specific and demanding challenge to develop flame retardant PUR materials.
Nowadays, various polymeric materials are used in E&E applications with sufficient flame retardance by adding rather different flame retardants. It doesn’t matter whether cables are used outdoor or are installed indoor as building products, the weathering exposures such as UV radiation, humidity and variation in temperature occur and influence the flame-retardant property. Recently, the lifetime of the flame retardance itself becomes an increasingly important factor. In this work, several devices were used to perform accelerated artificial ageing simulating different environment exposures.
The comprehensive and global understanding of the durability of flame retardance in dependence on the weathering or ageing conditions is still a matter of discussion. Therefore, the weathering resistance of various halogen-free fire-retarded polymers was investigated in this work. Polymeric systems with different kinds of fire retardants were chosen, including various fire retardant mechanisms. Ethylene Vinyl Acetate (EVA) blends with high amounts of inorganic flame retardant such as aluminum hydroxide (ATH), boehmite and synergists, which mainly dilutes the polymer resin work as heat sink and cooling agent, and enhance residue formation was examined. Thermoplastic Polyurethane (TPU) was modified with melamine cyanurate (MC), which mainly acts by changed melt flow and dripping behavior as well as fuel dilution. Additionally, aluminum diethylphosphinate and boehmite are induced as assistant flame retardant. Furthermore, glass fiber reinforced Polyamide 66 (PA) was investigated containing different kinds of aluminum diethylphosphinate based flame retardant mixtures, which acts by flame inhibition and additional char formation.
The degradation of the surface was analyzed after the different weathering conditions. Most of the specimens exhibited an intensive material degradation at the top surface accompanied by a distinct discoloration, e.g. getting darker or showing yellowing. The weathering of the EVA samples lead to numerous cracks (already) after 4000 h. The corresponding changes in the chemical structure was investigated by ATR FT-IR for all materials.
The flammability was investigated by cone calorimeter, UL-94 burning chamber, and oxygen index (LOI) using plate and bar specimens. The flame retardance of most of the materials studied degrades only slightly or were rather stable for the investigated exposure times. Interestingly, also some opposite results were found. EVA modified by different inorganic flame retardants such as ATH achieved higher LOI after exposing in the humidity chamber and the accelerated oxidation under water in the autoclaves. It is suggested that the particle size of ATH and boehmite plays an important role, when these flame retardants agglomerate at the surface during accelerated weathering.
Both materials, EVA and TPU, were also investigated as cable jackets. While EVA modified with inorganic flame retardants exhibits low-smoke and non-dripping fire behavior, TPU flame-retarded with MC yields cables with pronounced melt-dripping. Cone calorimeter tests were carried out using cable rafts of the size of 100 mm * 100 mm as well as our self-made cable module test, which simulates the vertical full-scale test of a bundle of cables at the bench-scale. Both methods were used to investigate the weathering resistance of the flame retardance in cables. The results of the cable module test for the flame-retarded EVA cables were only slightly affected even when a long time hydrothermal ageing was carried out. This is because of inorganic residue which just delays the fire growth but does not extinguish. However, for the flame-retarded TPU cable jackets, the cable module test exhibited an accelerated fire spread and a melt-dripping behavior which was promoted by weathering exposure.
Developing halogen‐free flame retardants with reasonably high efficiency, which thus function at limited loadings in polypropylene‐based wood/plastic composites (WPC), is still a challenge. Cost‐effective flame‐retarded WPC have been identified as a way to open the door to an interesting, broader spectrum of application in the building and transportation sectors. This work imparts a systematic comprehensive understanding and assessment of different basic routes to halogen‐free flame‐retarded WPC, taking into account economic and environmental considerations. Cheap, halogen‐free single‐component flame retardants and their multicomponent systems are investigated at reasonable filling grades of 20 wt%. The basic routes of promising synergistic multicomponent systems are discussed, and their potential and Limits assessed. Optimizing the consistency of fire residue; closing the surface of inorganic‐organic residual layers; the thermal stabilization and design of the residue, eg, synergistic combination of ammonium polyphosphate and expandable graphite; and the combination of different flame‐retardant mechanisms, eg, intumescence and flame inhibition, are proposed as promising routes to boost the flame‐retardant efficiency.
Rigid polyurethane foams (RPUFs) typically exhibit low thermal inertia, resulting in short ignition times and rapid flame spread. In this study, the fire phenomena of RPUFs were investigated using a multi-methodological approach to gain detailed insight into the fire behaviour of pentaneand water-blown polyurethane (PUR) as well as pentane-blown polyisocyanurate Polyurethane (PIR) foams with densities ranging from 30 to 100 kg/m3. Thermophysical properties were studied using thermogravimetry (TG); flammability and fire behaviour were investigated by means of the limiting oxygen index (LOI) and a cone calorimeter. Temperature development in burning cone calorimeter specimens was monitored with thermocouples inside the foam samples and visual investigation of quenched specimens’ cross sections gave insight into the morphological changes during burning. A comprehensive investigation is presented, illuminating the processes taking place during foam combustion. Cone calorimeter tests revealed that in-depth absorption of radiation is a significant factor in estimating the time to ignition. Cross sections examined with an electron scanning microscope (SEM) revealed a pyrolysis front with an intact foam structure underneath, and temperature measurement inside burning specimens indicated that, as foam density increased, their burning behaviour shifted towards that of solid materials. The superior fire performance of PIR foams was found to be based on the cellular structure, which is retained in the residue to some extent.
The individual and collective impacts of additives in melt dripping behaviour were studied under UL 94 vertical test conditions. A set of polyamide 6 (PA6) based materials compounded with melamine cyanurate (MCA) – a ˝dripping agent˝ – and glass fibre (GF) – a ˝non-dripping agent˝ - was investigated in detail. Dripping quantification was carried out during first and second ignition. The materials and their drops were investigated with respect to thermal decomposition, melt viscosity, and others properties. PA6 with V-2 classification improves to V-0 when MCA is added; and is worsened to HB in presence of glass fibre. Together, PA6/GF/MCA achieved V-2. The non-flaming drops of PA6/MCA are formed by oligomeric fragments. The flaming drops of PA6/GF contain a high amount of glass fibre. The dripping behaviour of PA6/GF/MCA under fire is a complex response of the specimen, but not explained by an easy superposition of the materials’ properties. The dripping behaviour is influenced by the interaction and concurrence of the different phenomena.
Thermoplastic starch polymer blends as biodegradable materials are well known and used mainly as packaging material. In order to exploit new application fields for these materials, additional properties such as flame retardancy or increased mechanical strength are required. This work focuses on the flammability and fire behavior of a thermoplastic starch/polyester blend reinforced with natural fibers derived from Mexican industry processes wastes, such as keratin fibers from the tannery industry or coconut fibers[1]. Different fiber contents as well as combinations of varying contents of aluminum trihydroxide, expandable graphite or ammonium polyphosphate were tested in LOI, UL94, cone calorimeter and TG-FTIR in order to investigate and assess the concentration dependence of the fibers and flame retardants as well as synergistic effects between both components. In combination with ammonium polyphosphate, the coconut fibers induce a synergistic effect by reinforcing the char residue and creating a more stable heat barrier during forced flaming combustion in the cone calorimeter. Synergism is also observed in the oxygen test. The recycling of otherwise wasted material is a true challenge in material development, thus this work is a first step in the direction of sustainable and biodegradable materials.
The fire behaviour of carbon fibre (CF) reinforced polymers differs in comparison to polymers. Fibres behave often inert with respect to pyrolysis, they change the melt flow and dripping behaviour, the heat absorption and transfer, the amount and properties of the fire residue and so on. Flame and fire retardancy concepts are needed not only suitable for the different fire protection goals typical for each application, but also tailored for composites. This field is illuminated by examples taken from different projects carried out in the group of the author in the recent years. The examples target on different applications through achieving reduction in reaction to fire controlling the fire risks (flammability, heat release) in the beginning and development of a fire and investigating the fire stability, when a severe flame is directly applied (key property in fully developed fires). Approaches to halogen-free flame retardancy in CF reinforced thermosets are presented as well as building up a bench and an intermediate scale testing of composites in fire applying mechanical load (up to 1 MN compression) and direct flame exposure (180 kW/m2) simultaneously. Indeed, e.g. we have investigated the fire stability of stringer reinforced shell components taken out from the fuselage of an aircraft.
The understanding of fire behaviour, fire resistance, and fire retardant modes of action in composites is a promising basis for target-oriented development. The role of flame inhibition, charring, and protective layer formation is discussed. Successful concepts are presented for fire retardancy tailored for different application as well as general guidelines for future development. Different phosphorus flame retardants are proposed to achieve halogen-free flame retardancy with respect to ignition and developing fires. Different protective approaches are sketched for addressing the fire stability of composites that is the most important fire risk for the fire resistance in structural applications.
ISO 10156:2010 contains a test method and a calculation method for flammability of gases and gas mixtures for the selection of cylinder valve outlets. The calculation method is used also to classify gas mixtures according to the national and international dangerous goods and dangerous substances regulations, e.g. according to the UN Recommendations on the Transport of Dangerous Goods (UN TDG) and the Globally Harmonized System of Classification and Labelling of Chemicals (UN GHS). The calculation method for gas mixtures requires substance parameters of the single components. These are the coefficients for the fire potential (Tci) and for inerting ability, the so-called nitrogen equivalence (Kk), which have been estimated conservatively by means of flammability data.
BAM checked Tci and Kk values of ISO 10156:1996 using three-component diagrams (Flammable gas-Inert-Air) of the CHEMSAFE® database. The experimental fundamentals and the principles of the calculation method are summarized in this paper. The revised data for Tci and Kk values were adopted in the tables of ISO 10156:2010.
Furthermore, subcategorization of flammable gases has been proposed by a UN working group and shall be implemented in the GHS in the meantime. The subcategorization requires the lower flammability limit (LFL) as an additional indicator. Therefore, a test method and a calculation method for LFL were proposed by BAM and have been implemented in the new draft of ISO/CD 10156:2016.
The calculation method for gas mixtures is based on Le Chatelier’s rule and was extended by using the Kk values for inert components in the mixture. The calculated LFLs of methane-inert gas mixtures were compared with experimental values for different types of inert gases. It could be shown that calculated LFLs are in good agreement with experimental values if the Kk values derived from three-component flammability diagrams are used. Although using the Kk values of ISO 10156:2010 leads to higher deviations, the results are still on the safe side.
The presentation will discuss the difference between EU and US standards for the determination of explosion (flammability) limits and limiting oxygen concentration. Small differences observed in measured values can be traced back to the different test apparatuses and criteria. The discrepancies can be much greater in the case of limiting oxygen concentration because of the high amount of inert gases and the corresponding low laminar burning velocities. The paper describes some examples and the influence of the chosen criteria on the results. The European and US standards use the criteria of flame propagation in open test vessels and of pressure rise in closed ones. The examples discussed show that flame propagation is still possible at very small pressure rise values, as observed much below the pressure rise criterion of usual standards. However, flame propagation in a process plant can cause an accident or explosion and must be avoided. Therefore, the flame propagation criterion is recommended to be used in chemical safety engineering. The European safety database CHEMSAFE contains expertevaluated safety data for cases where the determination method and criteria are known. Flammability characteristics based on the pressure rise criterion may suffice in certain cases, e.g. for explosion protection in closed vessels without any connecting pipes.
Since thermoplastics’ melt dripping is connected directly with their ability to make a fire scenario more or less dangerous, it has been investigated in greater detail. However, it has still remained a question mark in the field of the flammability of plastics. Once it was recognized that each polymer has its own dripping characteristics under equal, standardized conditions, efforts were made to better understand the specifics of this phenomenon. Several different polymers were tested under fire in order to study the relations between molecular structure and the dimensions of the drops. In particular, the relationship between the polymer decomposition mechanisms and their drops was investigated. New quantification methods helped to study drop yields from materials upon exposure to fire or heat. Polymers and flame-retarded polymers showed variations in dripping, indicating that this behaviour is a combination of melting and the decomposition of the polymer and additives. From this, the main material characteristics that influence dripping under fire were highlighted: temperature, viscosity and decomposition.
As Polyamide 6 (PA6) is a thermoplastic polymer used in a wide range of products, including electronic devices, interest in enhancing the fire retardancy of this type of polymer is high. Melamine cyanurate (MCA) has been reported to be the most important nitrogen-containing flame retardant used in polyamides, and is especially attractive because it is halogen-free. In addition, glass fibres (GF) are commonly used in PA6 to improve its mechanical properties, mainly for engineering applications. In order to contribute to the scientific discussion on dripping behaviour, this work reports on an experimental investigation of a set of PA6 materials compounded with different amounts of MCA and GF content. In UL 94 conditions, dripping quantifications were carried out during First Ignition (FIG) and Second Ignition (SIG). These flammability tests were recorded with an infrared camera. The thermal decomposition and rheological properties of all of the materials and collected drops were evaluated.
Dripping behaviour under fire is controlled by the polymer, the flame retardant and the reinforcement filler. Pure PA6 achieved a V-2 classification in UL 94 test, PA6/MCA V-0, PA6/GF HB, and the flame-retarded composites are also classified as V-2. In spite of these classifications, dripping behaviour observed during the flammability test was distinct for each type of samples, as described in the paper. As for decomposition, the PA6 drops collected had a starting decomposition temperature lower than pure PA6 (Figure 1.a), indicating partly decomposed PA6. PA6/MCA shows a clear, early decomposition step for MCA in thermogravimetry, which vanishes for the collected PA6/MCA drops, proving the complete decomposition of MCA during the UL 94 test. In PA6, glass fibres acted as inert filler, prolonging the time to dripping, and leading to a constant flaming flow (Figure 1.b) in the samples with high concentrations. When GF and MCA were combined in PA6/GF/MCA, the modes of action of both the GF and the MCA interfered with each other (Figure 1.c). GF reduces the effectiveness of MCA and tends to force its main action into the condensed phase. There the dripping behaviour is well restricted through the formation of thermally stable residues. Rheological properties and scanning electron microscopy images are consistent with these results.
FIGURE 1. Thermal decomposition of samples and drops of: a) PA6, b) PA6/30GF, and c) PA6/20GF/20MCA
Melt flow and dripping of polymeric materials can be both beneficial and detrimental during fire. In the vertical UL 94 test, a well adjusted dripping behaviour of flame retarded polypropylene (PP-FR) resulted in a non-flaming dripping V-0 classification. Melt flow and dripping reduce flame spread and even result in extinction, as mass and heat are removed from the actual pyrolysis zone. For the polymer samples and their drops collected in UL 94, the decomposition and viscosity was investigated. Particle finite element method (PFEM) was successfully used to simulate the material behaviour in the UL 94 test. The competition between gasification, combustion and melt dripping is evaluated.
Melt flow and dripping of polymeric materials can be both beneficial and detrimental during fire. It reduces flame spread and result in extinction, as mass and heat are removed from the actual pyrolysis zone. In contrast, melt flow and dripping can provide an additional ignition source, additional process of flame spread and has the potential to start a pool fire. In the vertical UL 94 test, a well adjusted dripping behaviour of flame retarded polypropylene (PP-FR) resulted in a non-flaming dripping V-0 classification. For the polymer samples and their drops collected in UL 94, the decomposition and viscosity was investigated. Particle finite element method (PFEM) was successfully used to simulate the material behaviour in the UL 94 test and increased the understanding of the complex behaviour of polymeric materials during fire.
The usage of concepts in scientific communication is critical to our ability to inform the reader about work that has been performed. The significance and thus the quality of scientific discussion rely on the precise use of concepts. In this second part of a two-part paper, concerning the scientific basis of polymer fire retardancy, the proper use of concepts is addressed. Distinct concepts in flame retardancy are discussed, such as fire residue, the correlation of fire performance with char yield according to van Krevelen, catalysis, and wicking. Synergy is discussed in detail, as well as approaches to quantify it, due to its importance for flame retardant polymers. The preceding first paper (part 1) discussed the proper use of scientific terms, thermal analysis, and fire testing. Thus, together these two papers support the community by offering recommendations and addressing some of the most relevant points. They encourage to review scientific practice in the field of flame retardancy of polymers.
The correct use of scientific terms, performing experiments accurately, and discussing data using unequivocal scientific concepts constitute the basis for good scientific practice. The significance and thus the quality of scientific communication rely on the proper use of terms and methods. It is the aim of this two-part article to support the community with recommendations for discussing the flame retardancy of polymers by addressing some of the most relevant points. The first article (part one of two) clarifies some scientific terms and, in some cases, such as for ‘‘pyrolysis,’’ ‘‘thermal decomposition,’’ and ‘‘fire resistance,’’ critically discusses their definitions in the field of fire science. Several comments are made on proper fire testing and thermal analysis, including some thoughts on uncertainty in fire testing. The proper use of distinct concepts in flame retardancy is discussed briefly in the subsequent second article (part two). This article tries to Balance imparting background on the subject with recommendations. It encourages to check scientific practice with respect to communication and applying methods.
Carbon black, multiwall carbon nanotubes, expanded graphite, multilayer graphene and graphene are compared comprehensively as flame retardants in nanocomposites to each other. Different polymer matrices are investigated as well as changing the concentration of the carbon fillers. Distinct combinations of graphene with conventional flame retardants are investigated. Phenomena and mechanisms are identified controlling the pyrolysis and fire behavior. The viscosity of the nanocomposites and their thermal conductivity as well are dramatically changed compared to the polymers influencing the time to ignition and flammability. During pyrolysis graphene functioned as inert filler and formed a residual protective layer reducing the peak heat release rate.
The influence of graphene on the effectivity of various conventional halogen-free flame retardants depends strongly on their modes of action. The addition of a small amount of graphene to an intumescent flame retardant poly(propylene) led to an improvement in the cone calorimeter. The further increase of graphene content gained deceleration of swelling and a decrease of the final height of the intumescent layer. In combination with metal hydroxide, 1 wt% graphene closed the macroscopic surface structure and densified the microscopic structure of the fire residues tremendously. Due to this improved residue structure, metal hydroxides and graphene showed synergistic cooperation in terms of oxygen index and UL 94 classification (HB/V-1 to V-0).
The presentation will discuss the difference between EU and US standards for the determination of explosion (flammability) limits and limiting oxygen concentration. Small differences observed in measured values can be traced back to the different test apparatuses and criteria. The discrepancies can be much greater in the case of limiting oxygen concentration because of the high amount of inert gases and the corresponding low laminar burning velocities. The paper describes some examples and the influence of the chosen criteria on the results. The European and US standards use the criteria of flame propagation in open test vessels and of pressure rise in closed ones. The examples discussed show that flame propagation is still possible at very small pressure rise values, as observed much below the pressure rise criterion of usual standards. However, flame propagation in a process plant can cause an accident or explosion and must be avoided. Therefore, the flame propagation criterion is recommended to be used in chemical safety engineering. The European safety database CHEMSAFE contains expert-evaluated safety data for cases where the determination method and criteria are known. Flammability characteristics based on the pressure rise criterion may suffice in certain cases, e.g. for explosion protection in closed vessels without any connecting pipes.
The presentation will discuss the difference between EU and US standards for the determination of explosion (flammability) limits and limiting oxygen concentration. Small differences observed in measured values can be traced back to the different test apparatuses and criteria. The discrepancies can be much greater in the case of limiting oxygen concentration because of the high amount of inert gases and the corresponding low laminar burning velocities. The paper describes some examples and the influence of the chosen criteria on the results. The European and US standards use the criteria of flame propagation in open test vessels and of pressure rise in closed ones. The examples discussed show that flame propagation is still possible at very small pressure rise values, as observed much below the pressure rise criterion of usual standards. However, flame propagation in a process plant can cause an accident or explosion and must be avoided. Therefore, the flame propagation criterion is recommended to be used in chemical safety engineering. The European safety database CHEMSAFE contains expert-evaluated safety data for cases where the determination method and criteria are known. Flammability characteristics based on the pressure rise criterion may suffice in certain cases, e.g. for explosion protection in closed vessels without any connecting pipes.
In recent years, different nanoparticles have been proposed and successfully introduced as nanofillers in rubber nanocomposites. In this study, multilayer graphene (MLG) is proposed as a nanoparticle that functions efficiently at low concentrations. MLG consists of just 10 or so graphene sheets. Chlorine isobutyl isoprene rubber (CIIR)/MLG nanocomposites with different MLG loadings were prepared using an ultrasonically assisted solution mixing procedure followed by two-roll milling. The incorporation of MLG provides a clear improvement in the rheological, mechanical, curing, and gas barrier properties of the nanocomposites. Adding only 3 phr ofMLGto CIIR increased the Young’s modulus by more than two times and reduced the permeability ofO2 andCO2 by 30%. Higher nanofiller concentrations yielded further improvement in the properties of the nanocomposites. Moreover, CIIR/MLG nanocomposites showed reduced flammability.
Multicomponent flame retardant systems containing aluminum diethylphosphinate in thermoplastic styrene–ethylene–butylene–styrene elastomers are investigated (oxygen index, UL 94, cone calorimeter, and mechanical testing). Solid-state nuclear magnetic resonance, scanning electron microscopy, and elemental analysis illuminate the interactions in the condensed phase. Thermoplastic styrene–ethylene–butylene–styrene elastomers are a challenge for flame retardancy (peak heat release rate at 50 kW m-2 > 2000 kW m-2, oxygen index = 17.2 vol%, no UL-94 horizontal burn rating) since it burns without residue and with a very high effective heat of combustion. Adding aluminum diethylphosphinate results in efficient flame inhibition and improves the reaction to small flame, but it is less effective in the cone calorimeter. Its efficacy levels off for amounts >~25 wt%. As the most promising synergistic system, aluminum diethylphosphinate/melamine polyphosphate was identified, combining the main gas action of aluminum diethylphosphinate with condensed phase mechanisms. The protection layer was further improved with several adjuvants. Keeping the overall flame retardant content at 30 wt%, aluminum diethylphosphinate/melamine polyphosphate/titanium dioxide and aluminum diethylphosphinate/melamine polyphosphate/boehmite were the best approaches. An oxygen index of up to 27 vol% was achieved and a horizontal burn rating in UL 94 with immediate self-extinction; peak heat release rate decreased by up to 85% compared to thermoplastic styrene–ethylene–butylene–styrene elastomers, to <300 kW m-2.
Hyperbranched poly(phosphoester)s as flame retardants for technical and high performance polymers
(2014)
A structurally novel hyperbranched halogen-free poly(phosphoester) (hbPPE) is proposed as a flame retardant in poly(ester)s and epoxy resins. hb polymeric flame retardants combine several advantages that make them an extraordinary approach for future flame retardants. hbPPE was synthesized by olefin metathesis polymerization according to a straightforward two-step protocol. The impact of hbPPE on pyrolysis, flammability (reaction-to-small-flame), and fire behavior under forced flaming conditions (cone calorimeter) was investigated for a model substance representing poly(ester)s, i.e. ethyl 4-hydroxybenzoate, and an epoxy resin of bisphenol A diglycidyl ether cured with isophorone diamine. The flame retardancy performance and mechanisms are discussed and compared to a commercial bisphenol A bis(diphenyl phosphate) (BDP). Both hbPPE and BDP combined gas-phase and condensed-phase activity; hbPPE is the more efficient flame retardant, and is proposed to be efficient in a greater variety of polymeric matrices. The hydrolysis of hbPPE is suggested to produce phosphorous acids, which, when available at the right temperatures, enhance the charring of the polymer in the condensed phase. The better fire protection behavior of the hbPPE is due not only to its higher phosphorus content, but also to the higher efficiency of the phosphorus it contains.
Nanotechnology is one of the key technologies of the 21st century. The exploitation of 'new' effects that arise from materials structured on the nano-scale has also been proposed successfully for flame retardancy of polymers since the end of the 90s. Of all of the approaches these include, at this time the use of nanocomposites offers the best potential for industrial application, also some other ideas are sketched, such as using electrospun nanofibers mats or layer-by-layer deposits as protection coatings, as well as sub-micrometer multilayer coatings as effective IR-mirrors. The general phenomena, inducing a flow limit in the pyrolysing melt and changing the fire residue, are identified in nanocomposites. Key experiments are performed such as quasi online investigation of the protection layer formation to understand what is going on in detail. The flame retardancy mechanisms are discussed and their impact on fire behaviour quantified. With the latter, the presentation pushes forward the state of the art. For instance, the heat shielding is experimentally quantified for a layered silicate epoxy resin nanocomposite proving that it is the only import mechanism controlling the reduction in peak heat release rate in the investigated system for different irradiations. The flame retardancy performance is assessed comprehensively illuminating not only the strengths but also the weak points of the concepts. Guidelines for materials development are deduced and discussed. Apart from inorganic fillers (layered silicate, boehmite, etc.) not only carbon nanoobjects such as multiwall carbon nanotubes, multilayer graphene and graphene are investigated, but also nanoparticles that are more reactive and harbor the potential for more beneficial interactions with the polymer matrix.
This dissertation is devoted to explicitly investigate the suitability of titania and silica based precursors for wood modification.
Novel TiO2 / SiO2 wood inorganic composites were prepared by two-step process. In first step, freshly prepared precursor solutions of silicon and titanium alkoxides were vacuum impregnated (one or more cycles) to oven dried pine sapwood (Pinius sylvestris L.). Precursor solutions with nano-scaled species and particulates (TiO2 and SiO2) were soaked by the entire wood matrix during this step. In (second) subsequent curing step, these penetrating liquids transformed into respective gel layers and depositions therein by sol-gel processing (in-situ hydrolysis-condensation).
Sol-gel based depositions were evenly covered on the cell walls in the form of thin layers. These gel films were not crack-free however; very few cracks were visible in the gel coatings present within the wood matrix of composites prepared with precursors of low alkoxide content. In addition, the gels were randomly distributed, found to be mainly deposited in the wood cell lumen and also localized in the cell walls as ESEM-EDX mapping revealed.
The impregnated samples show an increase in mass and volume expressed as weight percent gain (WPG) and bulking (B). Both of the parameters are decisive for tailoring a number of physical properties of the resultant composites. In general, moisture and water sorption capacities were decreased by 43 to 50 % while anti-swelling efficiency (ASE) and bending strength (MOE) of the precursor-modified wood (composite) were increased up to 34 % and 41 % respectively, when compared to unmodified wood. These improvements are attributed mainly to gel depositions in the wood structure that physically interact with the wood matrix consequently narrowing the main flow passages there and reinforcing strengths of the fiber.
These materials show superior resistance against fire of different scenarios. In small scale fire, their flame was retarded markedly (up to 78 % in optimum case) in comparison to wood controls as studied by oxygen index test (LOI). Cone calorimetric investigations revealed their better fire retardancy in terms of time resolved heat release rates (HRR) in the developing fire scenario. A remarkable reduction of 40 % in the second peak of HRR was achieved through sol-gel treatment. Furthermore, fire hazards such as CO and total smoke production were considerably lowered for these materials. Beside these improvements, reductions in first peak HRR and in fire load (total heat evolved) were not worth considering in compliance to fire retardancy principles. In relation to the mechanism of protection, it can be concluded that stable gel layer (independence of material loading) inside the wood retards markedly the proceeding combustion processes (oxidation) after first pyrolysis by improving the overall protection properties of the fire residue.
These materials show excellent resistance against bio-deterioration. Almost full decay protection was achieved against wood destroying brown rot fungi (Coniophora puteana and Poria placenta) in 10 weeks laboratory trials only with 1 mass% loadings (WPG). Mass loss in prolonged test (16 weeks) was similar to 10 week lasted test indicating that protection is permanent. In addition, composites imparted moderate resistances against soft rot fungi and very minor one against surface blue stain. The lowering in moisture content that discourages fungal colonization, gel layer that provides better shielding against fungal exposure and un-hydrolyzed alkoxides (organics) that probably induce biocidal effects are the main reasons for protection against biological attack in these materials.
Composites are utmost leach resistant because of the insolubility of gel depositions in water as well as due to their fixture into the wood matrix. In addition to this intrinsic property, gel precipitates can also reduce substantially (70 to 80 %) the release of hazardous active agents (e.g. CuCl2) of wood preservatives into the environment. This anti-leaching effect is supposed to be due to the reduced ion mobility of active agents inside the wood by their encapsulations into the gel matrix, lowering of water penetration into the wood depths as well as due to the internal covering action of the gel layer.
In short, it can be assessed that TiO2 / SiO2 based sol-gel precursor treatment of wood has a possibility to be commercialize in near future due to easy handling and non-toxic nature of the precursor used. Resultant end products (composites) are also novel and promising multifunctional materials that can be used for multi-purposes in relation to use class 3 (outdoor but without ground contact according to EN 335 2006) environments.
The use of coconut fiber (CF) agricultural waste was considered as an environmentally friendly and inexpensive alternative in flame retarded biocomposites. To decrease the high content of aluminum trihydrate (ATH) required, the thermal decomposition (thermogravimetry), flammability [oxygen index (LOI) and UL 94 test] and fire behavior (cone calorimeter) of a combination of CF and ATH were investigated in a commercial blend of thermoplastic starch (TPS) and cellulose derivatives. CF induced some charring activity, slightly decreasing the fire load and burning propensity in cone calorimeter test. ATH decomposes endothermically into water and inorganic residue. Significant fuel dilution as well as a pronounced residual protection layer reduces the fire hazards. Replacing a part of ATH with coconut fibers resulted in improved flame retardancy in terms of ignition, reaction to small flame, and flame-spread characteristics [heat release rate (HRR), fire growth rate (FIGRA), etc.]. The observed ATH and CF synergy opens the door to significant reduction of the ATH contents and thus to interesting flame retarded biocomposites.
Flammable gases and vapors
(2013)
ULLMANN'S Encyclopedia of Industrial Chemistry is the benchmark reference in chemistry and chemical and life science engineering, covering inorganic and organic chemicals, advanced materials, pharmaceuticals, polymers and plastics, metals and alloys, biotechnology and biotechnological products, food chemistry, process engineering and unit operations, analytical methods, environmental protection, and much more.
Fire retardancy effects in single and double layered sol-gel derived TiO2 and SiO2-wood composites
(2012)
Sol–gel derived TiO2 and SiO2-wood inorganic composites are prepared by direct vacuum infiltration of silicon and titanium alkoxide based precursors in pine sapwood in one or two cycles followed by a controlled thermal curing process. The resulting flame retardancy effect is investigated under two different fire scenarios using cone calorimetry and oxygen index (LOI). Heat release rates (HRR) especially the values for the second peak, are reduced moderately for all single layered composites. This effect is more pronounced for double layered composites where HRR was reduced up to 40 % showing flame retardancy potential in developing fires. Beside this, smoke release was lowered up to 72 % indicating that these systems had less fire hazards compared to untreated wood, whereas no meaningful improvement is realized in terms of fire load (total heat evolved) and initial HRR increase. However impressively, the LOI of the composites were increased up to 41 vol% in comparison to 23 vol% for untreated wood displaying a remarkable flame retardancy against reaction to a small flame. An approximate linear interdependence among the fire properties and the material loading as well as fire residue was observed. A residual protection layer mechanism is proposed improving the residue properties for the investigated composites.
The impact of the chemical structure of four different aryl bisphosphates on the flame retardancy of bisphenol A polycarbonate/acrylonitrile–butadiene–styrene blends (PC/ABS) was investigated. The impact of the bridging unit was studied, by comparing bisphenol A bis(diphenyl phosphate) BDP with biphenyl bis(diphenyl phosphate) BBDP and hydroquinone bis(diphenyl phosphate) HDP; as well as the influence of an aromatic substitution by comparing BBDP with biphenyl bis (di-2,6-xylyl phosphate) BBXP. The blends were investigated in terms of pyrolysis (thermogravimetry TG, TG coupled with Fourier transformed infrared spectroscopy (FTIR) and mass spectrometry (MS)) and fire performance (cone calorimeter, LOI, UL 94). The decomposition temperature of the flame retardant is a main parameter enabling a condensed phase interaction with PC decomposition products. The phosphate esters reacting with phenolic groups during pyrolysis were shown to increase cross-linking and reduce the hydrolysis/alcoholysis of the carbonate group. Variation of the aromatic substitution with the use of biphenyl bis (di-2,6-xylyl phosphate) led to reduced performance, highlighting the importance of the reactivity of the flame retardant with the decomposing PC.
The pyrolysis and flame retardancy of a bisphenol A polycarbonate/silicon rubber/bisphenol A bis(diphenyl phosphate) (PC/SiR/BDP) blend were investigated and compared to those of PC/BDP and PC/SiR. The impact modifier SiR consists mainly of poly(dimethylsiloxane) (PDMS > 80 wt %). The pyrolysis of PC/SiR/BDP was studied by thermogravimetry (TG), TG–FTIR to analyze the evolved gases, and a Linkam hot stage cell within FTIR as well as 29Si NMR and 31P NMR to analyze the solid residue. The fire performance was determined by PCFC, LOI, UL 94, and a cone calorimeter under different external irradiations. The fire residues were studied by using ATR-FTIR as well as the additional binary systems PC + PDMS, PC + BDP, and BDP + PDMS, focusing on the specific chemical interactions. The decomposition pathways are revealed, focusing on the competing interaction between the components. Fire retardancy in PC/SiR/BDP is caused by both flame inhibition in the gas phase and inorganic-carbonaceous residue formation in the condensed phase. The PC/SiR/BDP does not work as well superimposing the PC/SiR and PC/BDP performances. PDMS reacts with PC and BDP, decreasing BDP's mode of action. Nevertheless, the flammability (LOI > 37%, UL 94 V-0) of PC/SiR/BDP equals the high level of PC/BDP. Indeed, SiR in PC/SiR/BDP is underlined as a promising impact modifier in flame-retarded PC/impact modifier blends as an alternative to highly flammable impact modifiers such as acrylonitrile–butadiene–styrene (ABS), taking into account that the chosen SiR leads to PC blends with a similar mechanical performance.
For the classification of chemicals, special standardized test procedures have been developed and are used world-wide. Safe handling and use of these chemicals depend on the correct classification which
therefore must be based on the precise and correct execution of the tests and their evaluation. In this context interlaboratory tests (round robin tests, interlaboratory comparisons / intercomparisons) are a crucial element of a laboratory's quality system. Participation in interlaboratory tests is explicitly recommended by the standard ISO/IEC 17025. The present document reports on the results of the interlaboratory test 2007 on the method UN Test N.5 “Test method for substances which in contact with water emit flammable gases” [1] / EC A.12 “Flammability (contact with water)” [2] which was organized by the Center for Quality Assurance for Testing of Dangerous Goods and Hazardous Substances.
In dependence on the chemical structure and/or the physical form and state (e.g. particle size) substances or mixtures may be able to react with water (even water damp / air humidity) under normal ambient temperature conditions. Sometimes this reaction can be violent and/or with significant generation of heat. Especially if gases are evolved this reaction may become dangerous. In addition, it is important to know whether a substance emits flammable gases due to contact with water because
special precautions are necessary especially with regard to explosion protection. The methods UN Test N.5 and EC A.12 are applied to characterize chemical substances or mixtures which in contact with water emit flammable gases. To differentiate between chemicals with these properties and chemicals which are not classified as hazardous / dangerous, the substance’s gas evolution rate is determined and compared to the classification criteria(s) in the last step of the test
method. In the methods UN Test N.5 / EC A.12 no special laboratory apparatus / measuring technique to determine gas evolving flow is required. However, practical experience shows that the testing procedure for substances and mixtures which in contact with water emit flammable gases is sensitive to a number of influencing factors. Since the methods (UN N.5 / EC A.12) were developed and came into force in the early nineties a
systematic review concerning the practical application of the test method has not been carried out.
Layered silicate epoxy nanocomposites: formation of the inorganic-carbonaceous fire protection layer
(2011)
The layered silicate (LS) modification and processing parameters applied control the morphology of the LS/polymer composites. Here, increasing the surface area of the LS particles by using alternative drying processes increases dispersion towards a more typical nanocomposite morphology, which is a basic requirement for promising flame retardancy. Nevertheless, the morphology at room temperature does not act itself with respect to flame retardancy, but serves as a prerequisite for the formation of an efficient surface protection layer during pyrolysis. The formation of this residue layer was addressed experimentally for the actual pyrolysis region of a burning nanocomposite and thus our results are valid without any assumptions or compromises on the time period, dimension, surrounding atmosphere or temperature. The formation of the inorganic-carbonaceous residue is influenced by bubbling, migration, reorientation, agglomeration, ablation, and perhaps also delamination induced thermally and by decomposition, whereas true sintering of the inorganic particles was ruled out as an important mechanism. Multiple, quite different mechanisms are relevant during the formation of the residue, and the importance of each mechanism probably differs from one nanocomposite system to another. The main fire protection effect of the surface layer in polymer nanocomposites based on non-charring or nearly non-charring polymers is the increase in surface temperature, resulting in a substantial increase in reradiated heat flux (heat shielding).
The pyrolysis and the flame retardancy of poly(butylene terephthalate) (PBT) containing aluminum diethylphosphinate (AlPi) and nanometric Fe2O3 were investigated using thermal analysis, evolved gas analysis (Thermogravimetry-FTIR), flammability tests (LOI, UL 94), cone calorimeter measurements and chemical analysis of residue (FTIR). AlPi mainly acts as a flame inhibitor in the gas phase, through the release of diethylphosphinic acid. A small amount of Fe2O3 in PBT promotes the formation of a carbonaceous char in the condensed phase. The combination of 5 and 8 wt% AlPi, respectively, with 2 wt% metal oxides achieves V-0 classification in the UL 94 test thanks to complementary action mechanisms. Using PBT/metal oxide nanocomposites shows a significant increase in the flame retardancy efficiency of AlPi in PBT and thus opens the route to surprisingly sufficient additive contents as low as 7 wt%.
Bisphenol A polycarbonate/acrylonitrile–butadiene–styrene (PC/ABS) with and without bisphenol A bis(diphenyl phosphate) (BDP) and 5 wt.% zinc borate (Znb) were investigated. The pyrolysis was studied by thermogravimetry (TG), TG-FTIR and NMR, the fire behaviour with a cone calorimeter applying different heat fluxes, LOI and UL 94. Fire residues were examined with NMR. BDP affects the decomposition of PC/ABS and acts as a flame retardant in the gas and condensed phases. The addition of Znb results in an additional hydrolysis of PC. The fire behaviour is similar to PC/ABS, aside from a slightly increased LOI and a reduced peak heat release rate, both caused by borates improving the barrier properties of the char. In PC/ABS + BDP + Znb, the addition of Znb yields a borate network and amorphous phosphates. Znb also reacts with BDP to form alpha-zinc phosphate and borophosphates that suppress the original flame retardancy mechanisms of BDP. The inorganic–organic residue formed provides more effective flame retardancy, in particular at low irradiation in the cone calorimeter, and a clear synergy in LOI, whereas for more developed fires BDP + Znb become less effective than BDP in PC/ABS with respect to the total heat evolved.
Self-contained underwater breathing apparatus (SCUBA) divers use different mixtures of nitrogen and oxygen as breathing gas. The so-called NITROX mixture often contains more oxygen than is contained in air and may increase the fire hazard in diving equipment. The SCUBA diving community, however, still differentiates between NITROX mixtures that contain more than 40 % oxygen or less. They consider a mixture with up to 40 % oxygen often as regular air. In filling operations of SCUBA cylinders, gas flows from high pressure to low pressure. Because of compressive heating, a sudden temperature rise in the gas occurs and nonmetallic materials, e.g., seals may ignite. BAM has used the pneumatic impact test to investigate the ignition sensitivity of ethylene propylene diene monomer (EPDM), fluorelastomer (FPM), polytetrafluorethylene (PTFE), polyetheretherketone (PEEK), and nylon (PA 6.6) to gaseous impacts in synthetic air, in various NITROX mixtures, and in pure oxygen. The test results clearly show that for nonmetallic materials, the maximum pressure of nonreaction in NITROX mixtures decreases at a content of 29 % oxygen in comparison to those in air. In addition, autoignition temperatures of the nonmetallic materials were also determined. The findings of this investigation support very well the results of other publications on oxygen enrichment. As a consequence of this study, in SCUBA diving, the same safety requirements for NITROX mixtures with more than 21 % oxygen should be applied as for pure oxygen in the industry.
In oxygen components, even for high pressure oxygen service, it is possible to use organic seals, lubricants, or filling liquids, provided their oxygen compatibility has been checked. However, fire incidents in oxygen systems still occur because these materials ignite and burn. There are many reasons, such as incorrect design, contamination, faulty operation, unsuitable materials, etc., why this happens. Another cause that is overseen very often is proper maintenance on the user´s side. It is very important to replace in a component a worn out seal by the same one with identical oxygen compatibility properties. On the part of the producer or distributor of materials, batch testing and also a quality assurance system play a key role in the safety of an oxygen component. Any change in the manufacturing process of a material, or in its composition, and even its further processing may have an impact on its oxygen compatibility and finally on the component in which it is used. Numerous investigations by BAM over decades reveal the influence of minor constituents and fillers on a material´s oxygen compatibility. The test results in this paper show how important it is to regularly perform batch testing on nonmetallic materials used for oxygen service and to have a quality assurance system that helps minimize incidents where unsuitable materials are chosen by accident.
In this first of two papers, the thermal decomposition of bisphenol A bis(diphenyl phosphate)-flame retarded polycarbonate (PC) blends with different impact modifiers was studied. The impact modifiers were an acrylonitrile-butadiene-styrene (ABS), a poly(n-butyl acrylate) (PBA) rubber with a poly(methyl methacrylate) (PMMA) shell and two silicone-acrylate rubbers consisting of PBA with different amounts of polydimethylsiloxane (PDMS) and different shells (PMMA and styrene-acrylonitrile, SAN). The focus of this work was to study the impact of the acrylate and silicon-acrylate rubbers with respect to pyrolysis and flame retardancy in comparison to common ABS. Thermogravimetry (TG) was performed to investigate the pyrolysis behaviour and reaction kinetics. TG in combination with FTIR identified the pyrolysis gases. Solid residues were investigated by FTIR-ATR. PC/ABS shows two-step decomposition, with PC decomposing independently from ABS at higher temperatures. Pure acrylate rubber destabilises PC due to interactions between the rubber and PC, which leads to earlier decomposition of PC. Using silicone-acrylate rubbers led to similar results as PC/ABS with respect to pyrolysis, reaction kinetics and analysis of the solid residue; hence the exchange of ABS for the silicone-acrylate rubbers is possible.
In this second of a series of two papers, the fire behaviour of halogen-free flame retarded polycarbonate (PC) blends with different impact modifiers was studied. The impact modifiers were acrylonitrile-butadiene-styrene (ABS), a poly(n-butyl acrylate) rubber (PBA) with a poly(methyl methacrylate) (PMMA) shell and two silicone-acrylate rubbers consisting of PBA with different amounts of polydimethylsiloxane (PDMS) and different shell materials (PMMA and styrene-acrylonitrile, SAN). The flame retardant was bisphenol A bis(diphenyl phosphate) (BDP). Flammability was determined by LOI and UL 94. The burning behaviour under forced flaming conditions was studied by cone calorimeter under different external irradiations and by pyrolysis combustion flow calorimeter measurements. The exchange of ABS with the pure acrylate rubber worsened flammability, while similar results were obtained in cone calorimeter measurements. The exchange of ABS with the silicone-acrylate rubbers is promising, particularly with higher amounts of PDMS. In flammability tests strongly enhanced LOI values were obtained and therefore silicone-acrylate rubbers look like promising alternatives for ABS.