Filtern
Erscheinungsjahr
- 2016 (36) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (21)
- Vortrag (6)
- Sonstiges (4)
- Posterpräsentation (3)
- Beitrag zu einem Sammelband (1)
- Forschungsbericht (1)
Sprache
- Englisch (36)
Schlagworte
- XPS (14)
- NEXAFS (7)
- SIMS (5)
- ToF-SIMS (4)
- AES (3)
- Depth profiling (3)
- Metrology (3)
- Data fusion (2)
- EDX (2)
- Graphene (2)
Eingeladener Vortrag
- nein (6)
Soft x-ray spectromicroscopy techniques have seen great amount of development in the recent years, and with the development of new diffraction limited synchrotron source, many new nanoscale and mesoscale characterization opportunities of applied materials are foreseen. In this perspective, the authors present some examples that illustrate the capabilities of spectromicroscopy techniques, namely, 2D and 3D spatially resolved chemical quantification, surface and bulk sensitive measurements, and polarization dependent measurements as applied to iron oxide nanoparticulate materials of biological, geological, and other origins.
The photoinduced pseudorotaxane formation between a photoresponsive axle and a tetralactam macrocycle was investigated in solution and on glass surfaces with immobilized multilayers of macrocycles. In the course of this reaction, a novel photoswitchable binding station with azobenzene as the photoswitchable unit and diketopiperazine as the binding station was synthesized and studied by NMR and UV/Vis spectroscopy. Glass surfaces have been functionalized with pyridine-terminated SAMs and subsequently withmultilayers of macrocycles through layer-by-layer self assembly.
A preferred orientation of the macrocycles could be confirmed by NEXAFS spectroscopy. The photocontrolled Deposition of the axle into the surface-bound macrocycle-multilayers was monitored by UV/Vis spectroscopy and led to an increase of the molecular order, as indicated by more substantial linear dichroism effects in angle-resolved NEXAFS spectra.
Implantable drug delivery systems that provide controlled and sustained release of a therapeutic agent are used in a wide variety of applications. Drug eluting stents, which are used to treat coronary artery disease, are among the most widespread of these devices, with an estimated 3x10⁶ implants annually worldwide. Controlling the rate of drug release from these devices relies on precise control of the three dimensional (3D)-distribution of the drug, so methods for measuring this distribution are of great importance. The aims of this work were to determine how 3D-imaging of polymer-free sirolimus/probucol drug eluting stent coatings could be improved through the use of laser postionization secondary neutral mass spectrometry (Laser-
SNMS) and Ar cluster sputtering with time-of-flight secondary ion mass spectrometry (ToF-SIMS) and to optimize conditions for this analysis. In this study, 3D-imaging of a sirolimus/probucol dual drug eluting stent has been investigated using Laser-SNMS and ToF-SIMS. Laser-SNMS studies of pure sirolimus and probucol were undertaken using 30 keV Bi₃⁺ primary Ions and a 157 nm excimer postionization laser. Under optimal conditions, a greater than 100-fold increase in detected ion yield was observed for Laser-SNMS when compared to ToF-SIMS, although ToF-SIMS provided equal or greater yields for higher mass characteristic ions. Although the optimal laser power density for detecting probucol (5x10⁶W/cm²) was significantly lower than the optimum for sirolimus(7x10⁷W/cm²), an intermediate laser power density of 1x10⁷W/cm² was sufficient to allow imaging of both drugs. Using individual selected ion signals, ToF-SIMS and Laser-SNMS produced similar images of the two drug species. When using, however, a multivariate approach (Maximum autocorrelation factors), Laser-SNMS provided significant improvements in image contrast and small area detection when compared to ToF-SIMS.
Following optimization of the technique, 3D-images of the dual drug eluting stent coating were obtained using 10 keV Ar₂₀₀₀⁺ cluster ions for sputtering and 30 keV Bi₃⁺ cluster ions for Analysis for both ToF-SIMS and Laser-SNMS. This work demonstrates the advantages of Laser-SNMS for 3D-imaging of pharmaceutical devices, which has not been previously published. Both ToF-SIMS and Laser-SNMS revealed that the outermost surface of the drug eluting coating contained pure sirolimus to a depth of a few tens of nanometers, with a few channels of sirolimus extending to a depth of around 1 lm. Below about 1 lm, the two drugs were uniformly mixed. Using the 10 keV Ar₂₀₀₀⁺ sputter beam, the authors were able to sputter through the complete drug coating (~6 μm) without observing any accumulated damage in the organic layer. The two techniques showed complementary strengths: ToF-SIMS offers faster data collection and better detected ion yield for larger characteristic ions than Laser-SNMS, and Laser-SNMS offers significantly enhanced detected ion yield for smaller fragment ions, allowing for improved Image contrast and Resolution of smaller features.
Preparation of graphene oxide by cyanuric chloride as an effective and non-corrosive oxidizing agent
(2016)
In this work, we report a new method for the synthesis of graphene oxide (GO) using cyanuric chloride as a non-corrosive oxidizing agent.
The mild conditions, simple purification, and scalability of this method are significant advantages over common approaches in which harsh oxidizing agents are used. Moreover, a major drawback with the Hummers' method, the production of toxic gases, is not an issue with this process. This method is a safe and large-scale alternative for the production of GO under mild conditions.
A novel Infinitesimal Columns (IC) simulation model is introduced in this study for the quantitativeanalysis of core-shell nanoparticles (CSNP) by means of XPS, which combines the advantages of exist-ing approaches. The IC model is applied to stabilised Lumidot™CdSe/ZnS 610 CSNP for an extensiveinvestigation of their internal structure, i.e. calculation of the two shell thicknesses (ZnS and stabiliser)and exploration of deviations from the idealised CSNP composition. The observed discrepancies betweendifferent model calculations can be attributed to the presence of excess stabiliser as well as synthesisresidues, demonstrating the necessity of sophisticated purification methods. An excellent agreement isfound in the comparison of the IC model with established models from the existing literature, the Shardmodel and the software SESSA.
In this work, fullerene has been functionalized with cyanuric Chloride at room temperature by a nitrene mediated [2 + 1] cycloaddition reaction. The adduct after functionalization is inherently in the form of azafulleroid and shows broad UV absorption in the wavelength range of 200–800 nm, as well as photothermal conversion and fluorescence with a high quantum yield.
A comprehensive characterization of plasma modified polymer surfaces or plasma-polymerized thin films needs access to parameters as
- concentration of saturated/unsaturated carbon species (e.g. aromaticity) or other double bonds as C=N or C=O,
- branching, and
- losses of crystallinty or other degrees of structural order.
Furthermore the complex ageing phenomena of plasma modified polymers/plasma-polymers and the measurement of an in-depth distribution of chemical species are challenges for the analyst. The talk will display selected examples where such challenges have been met by using advanced methods of surface chemical analyses as Photoelectron Spectroscopy with variable excitation energy (“SyncXPS”), X-ray Absorption Spectroscopy (NEXAFS) at C, N and O K-edges and Time-of-Flight Secondary Mass Spectroscopy (ToF-SIMS) combined with Principal Component analysis (PCA).
Reference-free XRF is a SI traceable technique for the
determination of the mass deposition (mass per unit area) of elements in films on the nano- and micro scale. The method is radiometrically calibrated instrumentation (PTB@BESSY II, Germany) and based on reliable knowledge of all relevant atomic fundamental, experimental and instrumental parameters. No calibration sample or reference materials are necessary. The approach had been validated in the CCQM-P140 pilot study and the K129 key comparison by determination of mole fractions in Cu(In,Ga)Se2 thin films.
The certified reference material BAM-L200, a nanoscale stripe pattern for length calibration and specification of lateral resolution, is described. BAM-L200 is prepared from a cross-sectioned epitaxially grown layer stack of AlxGa1-xAs and InxGa1 xAs on a GaAs substrate. The surface of BAM-L200 provides a flat pattern with stripe widths ranging down to 1 nm. Calibration distances, grating periods and stripe widths have been certified by TEM with traceability to the length unit. The combination of gratings, isolated narrow stripes and sharp edges of wide stripes offers a plenty of options for the determination of lateral resolution, sharpness and calibration of length scale at selected settings of imaging surface analytical instruments. The feasibility of the reference material for an analysis of the lateral resolution is demonstrated in detail by evaluation of ToF-SIMS, AES and EDX images. Other applications developed in the community are summarized, too.
BAM-L200 fully supports the implementation of the revised International Standard ISO 18516 (in preparation) which is based on knowledge outlined in the Technical Report ISO/TR 19319:2013.
Graphene prepared from Graphene oxide (GO) is used as a platform for functional 2D nanomaterials with diverse applications ranging from bios ensors to antimicrobial surfaces. C and N K-edge NEXAFS and XPS spectroscopies at BESSY’s HE-SGM beamline have been used to prove and control covalent functionalization of graphenic materials at ambient conditions for the synthesis of functional 2D-surfaces.
The project addresses chemical and topographical metrology at surfaces. The new methodologies of measurements at surfaces will be developed as good practice guides and new work item proposals for industrial ISO standards. The objectives of the Joint research project (JRP) are to provide measurement standards and methods with traceability wherever it is practicable to do so for quantitative surface chemical analysis for industrial applications.
The certified reference material BAM-L200, a nanoscale stripe pattern for length calibration and specification of lateral resolution, is described. BAM-L200 is prepared from a cross-sectioned epitaxially grown layer stack of AlxGa1-xAs and InxGa1-xAs on a GaAs substrate. The surface of BAM-L200 provides a flat pattern with stripe widths ranging down to 1 nm. Calibration distances, grating periods and stripe widths have been certified by TEM with traceability to the length unit. The combination of gratings, isolated narrow stripes and sharp edges of wide stripes offers a plenty of options for the determination of lateral resolution, sharpness and calibration of length scale at selected settings of imaging surface analytical instruments. The feasibility of the reference material for an analysis of the lateral resolution is demonstrated in detail by evaluation of ToF-SIMS, AES and EDX images. Other applications developed in the community are summarized, too.
BAM-L200 fully supports the implementation of the revised International Standard ISO 18516 (in preparation) which is based on knowledge outlined in the Technical Report ISO/TR 19319:2013. Fundamental approaches to determination of lateral resolution and sharpness in beam-based methods
Materials and chemical producers require detailed knowledge of surface chemistry for research into new products. One way to understand a surface without damaging it is to bombard it with an electron beam, causing its atoms to emit characteristic X-rays enabling identification. The measurement of these must be precise as many elements emissions are close in energy – traceable reference materials will ensure instruments using this technique are stable and accurate.
Measuring organic layers
(2016)
Many innovative products - from touchscreens to solar panels to pharmaceuticals – utilise multiple organic layers to create complex functionality. New techniques have been developed to remove and measure layers individually enabling improved product development and assisting with quality assurance. However, manufacturers cannot be certain of the depth of layer being removed and new reference materials for these techniques are needed to increase uptake, and remove a major barrier to innovation.
Modifying or controlling surface chemistry is important in new product development, quality control and research. This is particularly true where functionality of surfaces, thin films and interfaces are key to the application, such as organic solar cells and devices for medical diagnostics. Surface chemical analysis aims to provide quantitative elemental, chemical state and functional group information from the surface of materials, but requires comparable test data and improved measurement traceability.
IND15 JRP SurfChem: Traceable quantitative surface chemical analysis for industrial applications
(2016)
The SurfChem project has made a significant contribution to traceable quantitative surface chemical analysis for industrial applications by delivering new certified reference materials and test samples for specific technical applications. Regular performance tests of instruments, metrological methodology for the detection of (bio)organic surface species, ambient and non-destructive surface chemical analysis for in-line process control and new in situ characterisation techniques of catalytically active surfaces have been achieved.
CCQM has established a framework of comparisons to demonstrate the international comparability of chemical measurements. The key point is the establishment of comparable measurements, with traceability to internationally or nationally stated references. The Surface Analysis Working Group (SAWG) has been formally founded in 2003. CCQM ratified the group as a full working group of CCQM in April 2003 with these terms of reference:
- to develop pilot studies and carry out key comparisons of national measurement standards for surface and micro/nano-analysis;
- to assist in identifying and establishing inter-laboratory work to improve the traceability of surface and micro/nano-analysis;
- to establish and update a work plan to be adopted by CCQM;
- to discuss and review the scope of the working group and to liase with other working groups related to nanotechnology.
Following the 2015 meeting of the CCQM, the pilot study CCQM-P130 “WD and ED Electron Probe Micro Analysis on Au-Cu alloys” lead by BAM&NIST has been finalized. The Key Comparison K-129 “Measurement of atomic fractions in Cu(In,Ga)Se2 Films” lead by KRISS has made substantial progress and is about to be finalized. The new Key Comparison K-136 on “BET specific surface of ” lead by UNIIM&BAM has made strong progress in 2015 and will be finished in 2016.
The implementation of new 2-D materials based technologies in production processes requires the development of quality management tools. These have to be underpinned by appropriate measurements. Consequently there is a need for the development of the metrology for measurement methods, the development of certified reference materials (CRM) and finally standardization. This chain represents the ideal way to practically useful standards. The presentation will give an overview on the main players in the field and summarize the recent status of activities. At the highest level the metrology of chemical characterization of 2D materials is in the scope of the International Meter Convention, specifically the Consultative Committee for Amount of Substance: Metrology in Chemistry and Biology (CCQM). Pre-standardization is an activity field of the Versailles Project on Advanced Materials and Standards (VAMAS). Standardization is mainly addressed by addressed ISO Technical Committees. A summary on available CRMs relevant to the characterization of nano materials has been prepared by BAM. Examples from the work of BAM’s Division 6.1 “Surface Analysis and Interfacial Chemistry” showcasing the characterization of chemically modified graphene surfaces are given and specific needs for the development of metrology are addressed.
In the discussion the audience is invited to define specific needs which will be streamlined to the respective bodies!
Real Time Imaging of Deuterium in a Duplex Stainless Steel Microstructure by Time-of-Flight SIMS
(2016)
For more than one century, hydrogen assisted degradation of metallic microstructures has been identified as origin for severe technical component failures but the mechanisms behind have not yet been completely understood so far. Any in-situ observation of hydrogen transport phenomena in microstructures will provide more details for further elucidation of these degradation mechanisms. A novel experiment is presented which is designed to elucidate the permeation behaviour of deuterium in a microstructure of duplex stainless steel (DSS). A hydrogen permeation cell within a TOF-SIMS instrument enables electrochemical charging with deuterium through the inner surface of the cell made from DSS. The outer surface of the DSS permeation cell exposed to the vacuum has been imaged by TOF-SIMS vs. increasing time of charging with subsequent chemometric treatment of image data. This in-situ experiment showed evidently that deuterium is permeating much faster through the ferrite phase than through the austenite phase. Moreover, a direct proof for deuterium enrichment at the austenite-ferrite interface has been found.
In the present work, the influence of deuterium on the microstructure of a duplex stainless steel type EN 1.4462 has been characterized by Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) supported by scanning electron microscopy (SEM), focused ion beam (FIB), electron back scattered diffraction(EBSD) and energy dispersive x-ray (EDX) investigations. Characterization has been carried out before and after electrochemical charging with deuterium which has been used as a tracer, due to its similar behavior to hydrogen in the steel microstructure. In a first approach, the distribution of the deuterium occurring at temperatures above 58 °C has been visualized. Further it turned out that sub-surface micro blisters are formed in the ferrite-austenite interface, followed by the formation of needle shaped plates and subsequent cracking at the ferrite surface. In the austenite phase, parallel cracking alongside twins and hexagonal close packed (martensitic) regions has been observed. In both phases and even in the apparent interface, cracking has been associated with high deuterium concentrations, as compared to the surrounding undamaged microstructure. Sub-surface blistering in the ferrite has to be attributed to the accumulation and recombination of deuterium at the ferrite-austenite interface underneath the respective ferrite grains and after fast diffusing through this phase. Generally, the present application of chemometric imaging and structural analyses allows characterization of hydrogen assisted degradation at a sub-micron lateral resolution.