Filtern
Erscheinungsjahr
- 2025 (3)
- 2024 (1099)
- 2023 (1933)
- 2022 (1942)
- 2021 (1730)
- 2020 (1344)
- 2019 (2398)
- 2018 (2337)
- 2017 (2513)
- 2016 (2192)
- 2015 (2295)
- 2014 (2171)
- 2013 (2347)
- 2012 (2246)
- 2011 (2247)
- 2010 (2230)
- 2009 (1886)
- 2008 (1562)
- 2007 (1425)
- 2006 (1359)
- 2005 (1467)
- 2004 (1393)
- 2003 (1611)
- 2002 (1344)
- 2001 (589)
- 2000 (560)
- 1999 (397)
- 1998 (282)
- 1997 (277)
- 1996 (311)
- 1995 (301)
- 1994 (167)
- 1993 (117)
- 1992 (115)
- 1991 (93)
- 1990 (82)
- 1989 (92)
- 1988 (92)
- 1987 (87)
- 1986 (62)
- 1985 (265)
- 1984 (147)
- 1983 (270)
- 1982 (252)
- 1981 (321)
- 1980 (272)
- 1979 (232)
- 1978 (253)
- 1977 (258)
- 1976 (245)
- 1975 (253)
- 1974 (222)
- 1973 (160)
- 1972 (24)
- 1971 (23)
- 1970 (27)
- 1969 (111)
- 1968 (87)
- 1967 (69)
- 1966 (77)
- 1965 (74)
- 1964 (82)
- 1963 (60)
- 1962 (74)
- 1961 (95)
- 1960 (81)
- 1959 (95)
- 1958 (95)
- 1957 (96)
- 1956 (76)
- 1955 (93)
- 1954 (54)
- 1953 (23)
- 1952 (15)
- 1951 (8)
- 1950 (19)
- 1944 (20)
- 1943 (3)
- 1942 (78)
- 1941 (96)
- 1940 (71)
- 1939 (37)
- 1938 (58)
- 1937 (57)
- 1936 (94)
- 1935 (324)
- 1934 (113)
- 1933 (85)
- 1932 (84)
- 1931 (86)
- 1930 (230)
- 1929 (466)
- 1928 (11)
- 1927 (136)
- 1926 (298)
- 1925 (199)
- 1924 (81)
- 1923 (269)
- 1922 (86)
- 1921 (93)
- 1920 (18)
- 1919 (28)
- 1918 (12)
- 1917 (19)
- 1916 (24)
- 1915 (32)
- 1914 (34)
- 1913 (31)
- 1912 (40)
- 1911 (39)
- 1910 (37)
- 1909 (38)
- 1908 (16)
- 1907 (51)
- 1906 (43)
- 1905 (35)
- 1904 (37)
- 1903 (35)
- 1902 (27)
- 1901 (37)
- 1900 (39)
- 1899 (38)
- 1898 (22)
- 1897 (24)
- 1896 (34)
- 1895 (39)
- 1894 (19)
- 1893 (25)
- 1892 (42)
- 1891 (21)
- 1890 (34)
- 1889 (38)
- 1888 (35)
- 1887 (16)
- 1886 (24)
- 1885 (27)
- 1884 (20)
- 1883 (29)
Dokumenttyp
- Vortrag (20130)
- Zeitschriftenartikel (18136)
- Posterpräsentation (6258)
- Beitrag zu einem Tagungsband (6057)
- Beitrag zu einem Sammelband (2318)
- Forschungsbericht (781)
- Sonstiges (380)
- Buchkapitel (360)
- Dissertation (302)
- Zeitschriftenheft (Herausgeberschaft für das komplette Heft) (263)
Sprache
- Deutsch (30632)
- Englisch (24562)
- Mehrsprachig (198)
- Französisch (42)
- Russisch (31)
- Spanisch (21)
- Ungarisch (11)
- Tschechisch (7)
- Italienisch (7)
- Japanisch (5)
Schlagworte
- Korrosion (443)
- Corrosion (422)
- Concrete (397)
- Fluorescence (355)
- Nanoparticles (339)
- Additive manufacturing (315)
- Simulation (271)
- Zerstörungsfreie Prüfung (254)
- LIBS (250)
- Hydrogen (236)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (2408)
- 6 Materialchemie (2330)
- 7 Bauwerkssicherheit (1894)
- 1 Analytische Chemie; Referenzmaterialien (1873)
- 9 Komponentensicherheit (1551)
- 5 Werkstofftechnik (1186)
- 4 Material und Umwelt (1142)
- 3 Gefahrgutumschließungen; Energiespeicher (862)
- 6.3 Strukturanalytik (649)
- 6.1 Oberflächen- und Dünnschichtanalyse (635)
Paper des Monats
- ja (103)
Photophysical and mechanistic studies, the comparison of different emitter classes, and the rational design of the next generation of molecular and nanoscale reporters require quantitative photoluminescence measurements and the reliable determination of the key performance parameter photoluminescence quantum yield (QY), i.e., the number of emitted per absorbed photons. This is of special importance for all photoluminescence applications in the life and material sciences in the UV/vis/NIR/SWIR. To improve the reliability and comparability of photoluminescence and QY measurements across laboratories, pitfalls, achievable uncertainties, and material-specific effects related to certain emitter classes must be explored. Also, suitable protocols and reference materials are needed which have been validated in interlaboratory comparisons for different wavelength regions and transparent and scattering luminophores.[1] Based on absolute and relative photoluminescence measurements of functional dyes and nanomaterials like semiconductor quantum dots and rods, spectrally shifting lanthanide upconversion nanocrystals, perovskites, and YAG:Cer converter materials, reliable methods for determining QY of transparent and scattering luminophores, nonlinear emitters, and solid luminescent nanomaterials have been developed.[2,3] Thereby, material- and method-related uncertainties of relative and absolute QY measurements and achievable uncertainties could be quantified for linear and nonlinear UV/vis/NIR/SWIR emitters and lately for also luminescent and scattering materials and solid phoshors, here in an interlaboratory comparison of three labs utilizing integrating sphere spectroscopy.[4,5] In addition, to provide simple tools for a better comparability of QY measurements, recently, a first set of UV/vis/NIR quantum yield standards has been developed and certified with complete uncertainty budgets.[6] In the following, the outcome of these studies will be presented, thereby addressing common pitfalls and providing recommendations on the performance of reliable QY measurements of linear and non-linear emitters in transparent, scattering, and solid samples.
Wasserstoff leistet als Energieträger der Zukunft einen entscheidenden Beitrag zur nachhaltigen Energieversorgung. Der Transport wird vorwiegend durch das europäische Ferngasleitungsnetz erfolgen. Bisherige Untersuchungen zeigen, dass bisher verwendete Rohrstähle grundsätzlich für den Wasserstofftransport geeignet sind. Diese Eignung ist nicht direkt auf Reparaturfragestellungen im Betrieb übertragbar, da Schweißungen aus technisch-ökonomischen Gründen oft unter fortwährendem Gasfluss durchgeführt werden.
Ein im Erdgasnetz angewandtes Konzept ist das Anbohren druckführender Pipelines („Hot Tapping“). Dazu werden Zylinderhalbschalen zuerst durch Längs- und dann per Rohrrundnähten an die Pipeline geschweißt. Essenziell ist dabei die maßgeschneiderte Wärmeeinbringung, um das „Durchbrennen“ in die Pipeline zu vermeiden. Für zukünftige Wasserstoffpipelines liegt der Fokus u.a. auf dünnwandigen Leitungen. Im Gegensatz zu Erdgas, führen die beim Schweißen erreichten hohen Temperaturen an der Innenseite der Pipeline zu einer zusätzlichen Wasserstoffaufnahme in den Rohrstahl mit möglicher Materialdegradation.
Zur praktischen Lösung der Fragestellung, sind internationale Aktivitäten im Gang. Diese umfassen bspw. die Möglichkeiten und Weiterentwicklung von realistischen Prüfkonzepten (u.a. durch maßstäbliche Bauteilversuche). Dazu untersucht die Bundesanstalt für Materialforschung und -prüfung (BAM) in einem DVGW-geförderten Kooperationsprojekt mit Gasnetzbetreibern, die Frage der Übertragbarkeit der Schweißkonzepte der Erdgastechnik auf zukünftiger Wasserstoffpipelines.
Reversible polycondensations are polycondensations that include equilibration reactions at any stage of the process. Syntheses of Polyesters in bulk involving transesterification reactions and syntheses of polyamides in bulk involving transamidation are typical examples. In 1950, Jacobson and Stockmayer published a first theory of reversible polycondensations based on experimental studies with aliphatic polyesters.[1,2] They explained the reversibility by the reversible formation of cyclic oligomers and low molar mass polymers from an active chain end (so-called “back-biting”). The formation of cycles via end-to-end cyclization was excluded in agreement with Flory´s theory of irreversible polycondensations.[3] The reinvestigation of the Jacobson-Stockmayer experiments by the authors in combination with theoretical considerations shows that the JS theory is wrong. [4,5] It turned out that the experimental scenario is far from the reality. In real polycondensations, intermolecular equilibration is faster than “back-biting”, and end-to-end cyclization is quite normal. The revised theory of step-growth polymerization predicts that in the ideal case of 100% conversion, all reaction products are cycles, regardless, of whether the step-growth polymerization is reversible or not.
Photophysical and mechanistic studies, the comparison of different emitter classes, and the rational design of the next generation of molecular and nanoscale reporters require quantitative photoluminescence measurements and the reliable determination of the key performance parameter photoluminescence quantum yield (QY), i.e., the number of emitted per absorbed photons. This is of special importance for all photoluminescence applications in the life and material sciences in the UV/vis/NIR/SWIR.
As part of the "Journées de Chimie Analytique, JCA Dschang 2024", this plenary scientific conference will explore how analytical electrochemistry is fundamentally changing modern chemical analysis methods. We will highlight key innovations such as wearable/handheld sensors, lab-on-a-chip, lab-on-paper, lab-on-a-glove, integrated detection systems with artificial intelligence, and point-of-care (POC) technologies. We will also address the couplings between analytical electrochemistry and various analytical techniques such as mass spectrometry (EC-MS), chromatography (EC-LC), spectroscopy [EC-spectroscopy (UV-VIS, Raman, IR, NMR)], microscopy [EC-microscopy (EM, AFM)], and capillary electrophoresis (EC-CE). These advances enable faster, more accurate, and more accessible analyses, opening new perspectives for research and practical applications in environmental science, food and agriculture, public health, and advanced materials.
Im Vortrag werden Ergebnisse aus Versuchen mit dem Controlled Thermal Severity (CTS)-Test vorgestellt, der für sehr stark eingespannte Kehlnähte bekannt ist. Niedriglegierte Schweißungen an hochfesten Stählen sind nicht anfällig für Erstarrungsrissbildung. Unter dem besonderen Einfluss eines hohen Einspanngrades wurde die Erstarrungsrissneigung durch Abmessen der Rissflächen als Funktion der Schweißparameter und des Einspanngrades für vier hochfeste Schweißzusätze im MAG-Schweißen untersucht. Die Tests zeigen, dass sowohl eine Erhöhung des Einspanngrades als auch eine Änderung der Schweißparameter (hinsichtlich Streckenenergie und Geschwindigkeit) zu mehr Erstarrungsrissfläche führen. Besonders die Kombination aus sehr hohem Einspanngrad und hoher Streckenenergie plus hoher Schweißgeschwindigkeit sollte im Sinne der Erstarrungsrissminimierung vermieden werden.
UFP-Emission beim 3D-Druck
(2024)
Desktop-3D-Drucker haben in der letzten Dekade große Popularität in Bildungseinrichtungen, kleinen Unternehmen und Privathaushalten erlangt. Weit verbreitet ist mittlerweile die „Fused Filament Fabrication (FFF)“ Technologie. Hier wird ein thermoplastisches Filament geschmolzen, durch eine Metalldüse extrudiert und anschließend schichtweise so auf ein Druckbett aufgetragen, dass ein 3D-Objekt entsteht. Das Filamentmaterial wird dabei thermisch stark belastet, was zur Emission von Aerosolen sowie flüchtigen organischen Verbindungen (VOC) führt. Dabei werden hauptsächlich ultrafeine Partikel (UFP, dP < 100 nm) freigesetzt werden, die sogar in manchen Fällen im sub-4nm Größenbereich einen signifikanten Anteil ausmachen können (Tang und Seeger 2024).
Die gesundheitliche Relevanz eingeatmeter UFP ist durch sehr viele Studien gut belegt. Während eines i.d.R. mehrstündigen FFF-Druckvorgangs wird ein Anwender mit diesen Luftschadstoffen im Innenraum exponiert, häufig ohne eine Einschätzung des damit verbundenen Risikos zu haben. Die Exposition kann durch technische Faktoren (z.B. Druckerausstattung und -einstellung, Innenraumventilation), aber auch erheblich durch die Filamentauswahl beeinflusst werden. Unser Vorschlag zur Risikominderung besteht in der Auszeichnung emissionsarmer Filamentprodukte mit dem Umweltzeichen „Blauer Engel“, um so den Verbrauchern eine fundierte Auswahl zu ermöglichen. In unserem Projekt entwickeln wir dafür ein kammerbasiertes, standardisierbares und robustes Prüfverfahren zur vergleichenden Messung der Emission aus Filamenten. Mit dem Strangdruck-Verfahren (engl. Strand Printing Method, SPM) wird eine festgelegte Filamentlänge mit konstanter Rate extrudiert und auf dem Druckbett abgelegt, ohne dabei ein 3D-Objekt aufzubauen. Diese Vorgehensweise reduziert den Einfluss experimentell schlecht zu kontrollierender Faktoren sowie die Ausfallquote. Eine detaillierte Beschreibung und die Vorteile von SPM werden in Tang und Seeger (2022) erläutert. SPM wurde bereits für 44 Filamentprodukte aus unterschiedlichen Polymeren und Additiven als Vergleichstest angewendet. Alle Messungen wurden in einer klimatisierten 1 m³-Emissionsprüfkammer durchgeführt. Die Gesamtanzahl der emittierten Partikel (TP) dient als Beurteilungsmaß, in Anlehnung an die Vergabegrundlage DE-UZ-219 des Umweltzeichens Blauer Engel für Laserdrucker. Unter den getesteten Filamentprodukten variiert TP um ca. vier Größenordnungen (1E+9 ≤ TP ≤ 1E+13). Auch innerhalb jeder der untersuchten Polymergruppen variierte TP signifikant. Die Partikelemission kann daher nicht allein nach dem Basispolymer kategorisiert werden. Unsere Resultate belegen, dass die Stärke der Partikelemission eher eine charakteristische und individuelle Eigenschaft eines Filamentproduktes ist. Die Herkunft der Polymere, die herstellerspezifischen Additive sowie die nicht deklarierte Verunreinigungen können einen starken Einfluss auf die Emission haben. Die Auszeichnung von emissionsarmen Filament-produkten verspricht somit eine einfache, aber effektive Maßnahme zu sein, um Verbrauchern eine Minderung des Expositionsrisikos beim FFF-3D-Druck zu ermöglichen.
The electrochemical behavior of 4-phenylurazole (Ph-Ur) was studied and the latter was used as a molecular anchor for the electrochemical bioconjugation of tyrosine (Y). Cyclic voltammetry (CV) and controlled potential coulometry (CPC) allowed to generate in situ from phenylurazole the PTAD (4-phenyl-3H-1,2,4-triazole-3,5(4H)-dione) species on demand for tyrosine electrolabeling. To evaluate the performance of tyrosine electrolabeling, coulometric analyses at controlled potentials were performed on solutions of phenylurazole and the phenylurazole-tyrosine mixture in different proportions (2:1, 1:1, and 1:2). The electrolysis of the phenylurazole-tyrosine mixture in the ratio (1:2) produced a charge of 2.07 C, very close to the theoretical value (1.93 C) with high reaction kinetics, a result obtained here for the first time. The products obtained were identified and characterized by liquid chromatography coupled to high-resolution electrospray ionization mass spectrometry (LC-HRMS and LC-HRMMS). Two products were formed from the click reactions, one of which was the majority. Another part of this work was to study the electrochemical degradation of the molecular anchor 4-phenylazole (Ph-Ur). Four stable degradation products of phenylurazole were identified (C7H9N2O, C6H8N, C6H8NO, C14H13N4O2) based on chromatographic profiles and mass spectrometry results. The charge generated during the electrolysis of phenylurazole (two-electron process) (2.85 C) is inconsistent with the theoretical or calculated charge (1.93 C), indicating that secondary/parasitic reactions occurred during the electrolysis of the latter. In conclusion, the electrochemically promoted click phenylurazole-tyrosine reactions give rise to click products with high reaction kinetics and yields in the (1:2) phenylurazole-tyrosine ratios, and the presence of side reactions is likely to affect the yield of the click phenylurazole-tyrosine reaction.
Ergot alkaloids, potent mycotoxins produced by Claviceps spp., particularly Claviceps purpurea, pose significant health risks when they contaminate rye and related cereals, leading to ergotism in humans and mammals [1]. In response, the European Union has established Regulation 2023/915, setting maximum residue levels for the sum of 12 principal ergot alkaloids and other mycotoxins including fumonisins (FUM), deoxynivalenol (DON), zearalenone (ZEN), and T2/HT2 toxins in food products. Given the prevalent co-occurrence of mycotoxins, their simultaneous detection is crucial for ensuring the safety of food and feed [2, 3].
Traditionally, chromatographic techniques such as liquid chromatography coupled with (tandem) mass spectrometry (LC-MS/MS) have been employed for multiplex detection of mycotoxins [4, 5]. While effective, these methods require specialized facilities, expensive equipment, and skilled personnel. Immunoassays like ELISA and lateral flow assays offer a more accessible alternative for rapid mycotoxin detection, yet they generally lack the capability for concurrent multi-toxin screening.
This study introduces the SAFIA (Suspension Array Fluorescence Immunoassay), a particle-based immunoassay utilizing fluorescence-encoded microparticles for the simultaneous detection of multiple analytes [6, 7]. The assay's innovative advancement comes with the inclusion of ergot alkaloids, a novel addition to its existing detection capabilities for fusarium toxins and trichothecenes, thereby expanding its scope to a broader range of mycotoxins. The assay employs antibodies targeting the ergoline moiety common to all major ergot alkaloids, facilitated by a synthesized hapten mimicking the ergoline structure. This hapten was conjugated to amino-functionalized beads, and a panel of five monoclonal antibodies was evaluated for hapten recognition, binding specificity, and competitive binding efficiency.
Our findings demonstrate that all antibodies displayed similar affinities towards the hapten and lysergol (a stable and less hazardous analogue of lysergic acid used for calibration), achieving detection limits as low as 2 ppb. Cross-reactivity studies and analysis of round-robin test material indicated a significant underestimation of ergot alkaloid levels in samples. However, accurate detection of ergot alkaloids remains feasible through the application of a correction factor to the results, which compensates for this underestimation and ensures the assay's effectiveness. Despite this adjustment, the necessity for enhancements in antibody specificity to improve assay accuracy is evident. Furthermore, the inclusion of the ergot assay in a multiplexed setup for detecting FUM, DON, ZEN, and T-2 toxins showed no interference, although an unexpected inhibition among four out of five ergot antibodies was observed. This underscores the need for an improved immunogen structure to achieve optimal detection of ergot alkaloids.
In conclusion, our study presents a promising approach for the multiplexed detection of ergot alkaloids alongside other mycotoxins, highlighting the potential of SAFIA in enhancing food and feed safety through improved mycotoxin screening. Future work will focus on refining antibody specificity and assay configurations to overcome current limitations and ensure accurate, comprehensive mycotoxin detection.
Currently, there is a growing interest in the study of environmental degradation pathways of organic contaminants such as pesticides, with the objective to better understand their potential risk for environmental systems and living organisms. In this context, DFT (conceptual density functional theory) and predictive methods may systematically be used to simplify and accelerate the elucidation of environmental degradation. We report herein the electrochemical behavior/degradation of the carbendazim (CBZ) fungicide widely used to treat cereal and fruit crops. Oxidative degradation of CBZ was studied using an electrochemical flow-through cell directly coupled to a mass spectrometer for rapid identification of CBZ degradation products. The structural elucidation of CBZ oxidation products was based on retention time, accurate mass, isotopic distribution and fragmentation pattern by using LC-HRMS an LC-HRMS2. The most important chemical reactions found to occur in the transformation of CBZ were hydrolysis and hydroxylation. EC-LC-MS and EC-MS analysis has made it possible to highlight the identification of degradation products of CBZ. In addition to previously known transformation products common to those observed during environmental degradation (monocarbomethoxyguanidine, benzimidazole-isocyanate, 2-aminobenzimidazole, hydroxy-2-aminobenzimidazole, hydroxycarbendazim, CBZ-CBZ dimer), two new degradation products were identified in this work: a quinone imine and a nitrenium ion. Electrochemistry mass spectrometry hyphenated techniques represent an accessible, rapid and reliable tool to elucidate the oxidative degradation of CBZ, including reactive degradation products and conjugates.
Data-driven materials design aims to predict and optimize material properties, such as stability and thermal conductivity, which are influenced by vibrational behavior. Approaches like DFT are computationally demanding and have limitations for phonon calculations. Machine learning-driven interatomic potentials (MLIP), like the Gaussian approximation potential (GAP), offer a more efficient alternative.1–8 We developed a Python workflow to automate MLIP generation using the Materials Project database.9 DFT computations, MLIP fitting and benchmark steps are automated.10,11 This approach accelerates phonon calculations and supports testing different data generation strategies and hyperparameters, and further validation12 is planned. Our goal is to provide open-source code and share these potentials.
Resistance to carbonation and chloride migration are critical durability properties in cementitious construction materials. The ingress of CO2 and chlorides can lead to concrete deterioration and reinforcement corrosion, underscoring the importance of ensuring high resistance to these durability-reducing factors. Traditional methods, such as determinating the carbonation coefficient using standard procedures, are time-consuming and resource-intensive. These tests typically require 42 days of preconditioning, followed by 70 days before the final results can be determined using a phenolphthalein test, for a total duration of 112 days. In addition, some test chambers can only accommodate four samples at a time.
In this study, we investigate whether 1H NMR relaxometry can effectively predict not only the carbonation resistance, KAC,3%, but also the chloride migration coefficient, DRCM, and the compressive strength, fc, of concrete, providing a method that could potentially streamline and accelerate the material development process by directing us quickly to potentially well-suited formulations. We performed measurements on non-carbonated fully saturated concrete and mortar samples at 28, 56, and 92 days using the NMR tomograph at BAM (8.9 MHz). Notably, the NMR measurements taken at 28 days showed no significant differences, suggesting that this timeframe is sufficient for meaningful results. The samples analyzed were drill cores, each 70 mm in diameter and approximately 120 mm in height. The NMR features we focused on included the initial amplitude E0, the x and y values of the dominant T2 relaxation time, and the logarithmic mean of the T2 relaxation time distribution. Another key feature was the surface relaxivity, which was determined by comparing the NMR curves with results from mercury intrusion porosimetry. We examined the correlation of these NMR features with the aforementioned durability properties, which were determined in a laboratory on sister samples using standard procedures. No chloride migration tests were performed on the mortar samples, and the carbonation procedure was carried out unter atmospheric conditions.
The preliminary results show that the correlation factors for the NMR features with the carbonation coefficients of concrete were particularly remarkable. The strongest correlations were observed for the dominant relaxation time and the logarithmic mean, with values approaching 1. The preliminary results also indicate that there are high correlations between the compressive strength and amplitude-related features. In contrast, no strong correlations are observed for the DRCM. Although the results related to the mortar samples are still being analyzed, these initial correlations suggest that 1H NMR relaxometry could be a valuable tool for early assessment of material properties. Furthermore, the rapid and non-destructive nature of NMR measurements, requiring only a few minutes per sample, suggests that this technique has the potential to significantly accelerate the process of evaluating durability properties in cementitious materials. This capability also paves the way for the use of NMR features as input for AI-driven predictive models.
Weitestgehendes Recycling vorhandener Materialien und Produkte ist ein wesentlicher Bestandteil der Kreislaufwirtschaft. Verpackungen auf Kunststoffbasis, darunter Behälter für Lebensmittel und Getränke, aber auch für die Lagerung und den Transport von Chemikalien und Gefahrgütern, werden derzeit größtenteils aus fossilen Rohstoffen hergestellt. Doch selbst für diese „kontaktempfindlichen“ Produkte besteht weiterhin das Ziel der Nachhaltigkeit durch den Einsatz von Recyclingmaterialien. Diese sehr aktuelle Diskussion findet derzeit im Rahmen der EU-Verpackungs- und Verpackungsabfallverordnung (PPWR) statt, die voraussichtlich noch in diesem Jahr abgeschlossen sein wird. Bei Verpackungen für den Transport gefährlicher Güter sind die Sicherheitseigenschaften der Behälter aus „neuen“ Materialien, einschließlich Polyethylen (PE), gut bekannt und werden im Rahmen ihrer Bauartzulassung getestet. Über ihre Gegenstücke aus Recyclingmaterialien ist jedoch weitaus weniger bekannt. Abgesehen von Materialschwächung kann der Eintrag von Rückständen in recycelte Kunststoffe zu einer Verunreinigung der Waren in der Verpackung führen.
Um diese Lücke zu schließen, haben wir Kanister aus hochdichtem PE (HDPE) aus Post-Consumer-Abfällen auf die Freisetzung von Kunststoffzusätzen und Verunreinigungen untersucht. Mithilfe eines umfassenden, nicht zielgerichteten Ansatzes mit hochauflösender Massenspektrometrie (HRMS) konnten wir je nach Art der gelagerten Chemikalie und Lagerdauer 895 verschiedene Komponenten detektieren. Die meisten Komponenten waren alleinig oder in wesentlich höherer Konzentration in recyceltem HDPE als in herkömmlichem HDPE nachzuweisen. 154 der Komponenten konnten identifiziert und auf ihre funktionale Verwendung hin analysiert werden. Interessanterweise ergab diese Analyse „Kosmetik“, „Duftstoffe“ und „Geschmacksstoffe“ als Hauptassoziationen neben bekannten und erwarteten Verwendungen im Bereich „Kunststoffe“. Dies deutete auf einen erheblichen Eintrag von Fremdverunreinigungen in das Produkt hin. Rezyklierte Kanister zeigten damit deutliche Nachteile im Vergleich zu herkömmlichen Kanistern. Eine detaillierte Bewertung der Ergebnisse im Hinblick auf die Materialsicherheit in diesem Produktsegment steht noch aus.
The carbonation resistance of alkali-activated materials (AAMs) is a crucial parameter for their applicability in concrete construction, yet the parameters influencing it are insufficiently understood to date. In the present study, the carbonation resistance of alkali-activated concretes with varying fractions of ground granulated blast furnace slag (GGBFS) and calcined clay (i.e., high, intermediate, and low Ca contents) were assessed under natural and accelerated conditions. Corresponding hardened AAM pastes were studied using X-ray diffraction, thermogravimetry, Raman microscopy, and mercury intrusion porosimetry. The carbonation resistance of the concretes at natural CO2 concentration depended principally on their water/(CaO + MgOeq + Na2Oeq + K2Oeq) ratio. The remaining variability for similar ratios was caused by differences between the pore structures of the AAMs. For concrete with favorable water/(CaO + MgOeq + Na2Oeq + K2Oeq) ratio and pore structure, the carbonation resistance was comparable to that of Portland cement concrete. The relationship between carbonation coefficients obtained under accelerated and natural conditions differed for concretes with high and low fractions of calcined clay, indicating that accelerated carbonation testing is less suitable to study the carbonation of low-Ca AAMs.
Im Beitrag werden Ergebnisse aus Versuchen mit dem Controlled Thermal Severity (CTS)-Test vorgestellt, der für sehr stark eingespannte Kehlnähte bekannt ist. Niedriglegierte Schweißungen an hochfesten Stählen sind nicht anfällig für Erstarrungsrissbildung. Unter dem besonderen Einfluss eines hohen Einspanngrades wurde die Erstarrungsrissneigung durch Abmessen der Rissflächen als Funktion der Schweißparameter und des Einspanngrades für vier hochfeste Schweißzusätze im MAG-Schweißen untersucht. Die Tests zeigen, dass sowohl eine Erhöhung des Einspanngrades als auch eine Änderung der Schweißparameter (hinsichtlich Streckenenergie und Geschwindigkeit) zu mehr Erstarrungsrissfläche führen. Besonders die Kombination aus sehr hohem Einspanngrad und hoher Streckenenergie plus hoher Schweißgeschwindigkeit sollte im Sinne der Erstarrungsrissminimierung vermieden werden.
Die Entwicklung zukünftiger Generationenvon stationären Gasturbinen verfolgt das Hauptziel, den thermischen Wirkungsgrad zu erhöhen, bei gleichzeitiger Reduktion der CO2-Emissionen. Ein mögliches Lösungskonzept besteht darin, bestehende Turbinenkonzepte auf nachhaltig erzeugten Wasserstoff umzustellen. Durch den Betrieb mit Wasserstoff entsteht eine erhöhte Belastung für konventionelle thermische Hitzeschutzkomponenten. Daher ist die Entwicklung von sogenannte Environmental Barrier Coatings (EBC) oder Materialkonzepten, die eine thermodynamische Stabilität in heißer Gasumgebung aufweisen, erforderlich.
Flow cytometry-based immunoassays are valuable in biomedical research and clinical applications due to their high throughput and multianalyte capability, but their adoption in areas such as food safety and environmental monitoring is limited by long assay times and complex workflows. Rapid, simplified bead-based cytometric immunoassays are needed to make these methods viable for point-of-need applications, especially with the increasing accessibility of miniaturized cytometers. This work introduces superparamagnetic hybrid polystyrene-silica core−shell microparticles as promising alternatives to conventional polymer beads in competitive cytometric immunoassays. These beads, featuring high specificity, sensitivity, and excellent handling capabilities via magnetic separation, were evaluated with three different antibodies and binding methods, showing variations in signal intensity based on the antibody and its attachment method. The optimal performance was achieved through a secondary antibody binding approach, providing strong and consistent signals with minimal uncertainty. The optimized protocol made it possible to achieve a detection limit of 0.025 nM in a total assay time of only 15 min and was successfully used to detect ochratoxin A (OTA) in raw flour samples. This work highlights the potential of these beads as versatile tools for flow cytometry-based immunoassays, with significant implications for food safety, animal health,
environmental monitoring, and clinical diagnostics.
Single-particle inductively coupled plasma-mass spectrometry (sp-ICP-MS) is one of the most powerful tools in the thriving field of nanomaterial analysis. Along the same lines, single-cell ICP-MS (sc-ICP-MS) has become an invaluable tool in the study of the variances of cell populations down to a per-cell basis. Their importance and application fields have been listed numerous times, across various reports and reviews. However, not enough attention has been paid to the immense and ongoing development of the tools that are currently available to the analytical community for the acquisition, and more importantly, the treatment of single-particle and single-cell-related data. Due to the ever-increasing demands of modern research, the efficient and dependable treatment of the data has become more important than ever. In addition, the field of single-particle and single-cell analysis suffers due to a large number of approaches for the generated data—with varying levels of specificity and applicability. As a result, finding the appropriate tool or approach, or even comparing results, can be challenging. This article will attempt to bridge these gaps, by covering the evolution and current state of the tools at the disposal of sp-ICP-MS users.
Graphical Abstract
Metallic materials, predominantly steels, are the most common structural materials in the various components along the hydrogen supply chain. Ensuring their sustainable and safe use in hydrogen technologies is a key factor in the ramp-up of the hydrogen economy. This requires extensive materials qualification, however, most of the accepted; and standardized test methods for determining the influence of gaseous hydrogen on metallic materials describe complex and costly procedures that are only available to a very limited extent worldwide. The hollow specimen technique is a simple, rapid, and economical method designed to overcome the limitations of the current methods for the qualification of metallic materials under high-pressure hydrogen gas. However, this technique is not yet standardized. The TransHyDE-H2Hohlzug project is presented in this article, along with the main steps required to optimize the hollow specimen technique. This includes closing knowledge gaps related to the specimen geometry, surface quality, and gas purity in dedicated working packages, thus contributing to a comprehensive standardization of the technique for tests in high-pressure hydrogen gas.
The analysis of per- and polyfluoroalkyl substances (PFAS) via sum parameters like extractable organic fluorine (EOF) in combination with high resolution-continuum source-graphite furnace molecular absorption spectrometry (HR–CS–GFMAS) is highly promising regarding fluorine sensitivity and selectivity. However, the HR–CS–GFMAS method includes several drying and heating steps which can lead to losses of volatile PFAS before the molecular formation step using e.g., GaF formation. Hence, the method leads to a strong discrimination of PFAS within the EOF depending on their physical/chemical properties and is therefore associated with reduced accuracy. To reduce this discrepancy and to indicate realistic PFAS pollution values, an optimization of the HR–CS–GFMAS method for PFAS analysis is needed. Hence, we determined fluorine response factors of several PFAS with different physical/chemical properties upon application of systematic optimization steps. We could therefore improve the method's sensitivity for PFAS analysis using a modifier drying pre-treatment step followed by a sequential injection of sample solutions. The highest improvement in sensitivity of volatile PFAS was shown upon addition of a Mg modifier during drying pre-treatment. Thereby, during optimization the relative standard deviation of fluorine response factors could be reduced from 55 % (initial method) to 27 % (optimized method) leading to a more accurate determination of organofluorine sum parameters. The method provides an instrumental LOD and LOQ of β(F) 1.71 μg/L and 5.13 μg/L, respectively. Further validation aimed to investigate several matrix effects with respect to water matrices. Here, substance-specific behavior was observed. For example, perfluorooctanoic acid (PFOA) which was used as calibrator, showed signal suppressions upon high chloride concentrations (>50 mg/L). Hence, a thorough separation of Cl from analytes during sample preparation is needed for accurate sum parameter analysis.