Filtern
Erscheinungsjahr
- 2024 (311)
- 2023 (839)
- 2022 (819)
- 2021 (708)
- 2020 (399)
- 2019 (1102)
- 2018 (1008)
- 2017 (1103)
- 2016 (912)
- 2015 (1030)
- 2014 (1012)
- 2013 (1032)
- 2012 (996)
- 2011 (985)
- 2010 (1024)
- 2009 (902)
- 2008 (659)
- 2007 (650)
- 2006 (612)
- 2005 (677)
- 2004 (642)
- 2003 (789)
- 2002 (606)
- 2001 (151)
- 2000 (138)
- 1999 (109)
- 1998 (94)
- 1997 (101)
- 1996 (76)
- 1995 (84)
- 1994 (56)
- 1993 (39)
- 1992 (40)
- 1991 (34)
- 1990 (28)
- 1989 (29)
- 1988 (22)
- 1987 (34)
- 1986 (18)
- 1985 (19)
- 1984 (15)
- 1983 (7)
- 1982 (14)
- 1981 (13)
- 1980 (6)
- 1979 (4)
- 1978 (8)
- 1977 (5)
- 1976 (2)
- 1975 (3)
- 1971 (1)
- 1969 (1)
- 1968 (1)
- 1967 (1)
- 1961 (1)
- 1950 (1)
Dokumenttyp
- Vortrag (19972) (entfernen)
Sprache
- Deutsch (13129)
- Englisch (6792)
- Mehrsprachig (24)
- Spanisch (13)
- Französisch (9)
- Russisch (3)
- Tschechisch (1)
- Ungarisch (1)
Referierte Publikation
- nein (19972)
Schlagworte
- Korrosion (250)
- Corrosion (138)
- Additive manufacturing (124)
- Additive Manufacturing (123)
- Additive Fertigung (115)
- Concrete (107)
- Hydrogen (103)
- Nanoparticles (96)
- LIBS (92)
- Wasserstoff (83)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (929)
- 6 Materialchemie (847)
- 7 Bauwerkssicherheit (823)
- 9 Komponentensicherheit (744)
- 1 Analytische Chemie; Referenzmaterialien (584)
- 5 Werkstofftechnik (460)
- 4 Material und Umwelt (440)
- 3 Gefahrgutumschließungen; Energiespeicher (426)
- 9.4 Integrität von Schweißverbindungen (355)
- 7.6 Korrosion und Korrosionsschutz (352)
Standardised methods need validation. The main validation parameters like trueness, repeatability and intermediate precision and reproducibility are presented. Furthermore, different methods for the validation are disussed: (certified) reference materials, representative testing materials and interlaboratory comparisons. At last, the need of proficiency testing is stressed.
Small-area XPS analysis is one of the most popular and powerful methods for analysing the surface of features in the micro-range. When measuring microstructures, the ques-tion arises whether the measuring point is really located at the point intended to be ana-lysed. Information in a measured spectrum might originate within the field of view (FoV) on the surface of the sample, from outside the FoV, or even from inherent contamination. To ensure that small structures can be measured correctly regardless of user and instru-ment, certain instrument and sample settings must be known and selected correctly: beam and aperture size as well as the aperture settings and the approximate dimensions of the structure to be analysed. This is the only way to ensure that the information in the spectrum originates only from the FoV on the analysed structure.
To test the performance of the XPS instruments, a dedicated test material was developed that consists of a gold surface on which 8 circles and 8 squares of chrome are incorpo-rated using a masking process, so that the Au substrate and the Cr structure surfaces are in the same surface plane. In order to be able to test as many as possible instruments from different manufacturers, the structures have been designed with a size ranging from 300 µm down to 7 µm. The layout of the test material has been optimised in regard of the handling. The structures are arranged along lines instead of a circumference, marking arrows around the smaller structures (≤50 µm) are added, and the lithography mask is optimised regarding edge and diffraction effects. Furthermore, the manufacturing process was changed from electron-beam deposition to mask lithography due to costs reasons. The structures on the test material were measured with a metrological SEM to determine their accurate dimensions and check the repeatability of the manufacturing process. XPS investigations with a Kratos AXIS Ultra DLD and an ULVAC-Phi Quantes demonstrates the suitability of this new test material for measuring the analysed area.
Bei Geräten und Maschinen zur bestimmungsgemäßen Verwendung in explosionsgefährdeten Bereichen gemäß 2014/34/EU muss in der europäischen Union eine Zündgefahrenbewertung durchgeführt werden. Dabei müssen unter anderem die Gefahren von nichtelektrischen Zündquellen betrachtet werden, zu denen auch die mechanischen Schlagvorgänge gehören.
Bei mechanischen Schlagvorgängen kommt es infolge des Zusammenstoßes zweier Werkstücke bzw. Bauteile zu einer Umwandlung der kinetischen Energie. Dabei erhöht sich die Temperatur der Werkstoffe an der Kontaktstelle und es kommt unter Umständen zu einem Abtrennvorgang kleiner Partikel erhöhter Temperatur. Sowohl die heißen Kontaktstellen (Zündquelle "heiße Oberflächen") als auch die abgetrennten Partikel (Zündquelle "mechanisch erzeugte Funken") können eine wirksame Zündquelle für ein explosionsfähiges Gasgemisch darstellen.
Zur Festlegung von Grenzwerten wurden in der Norm DIN EN ISO 80079-36:2016 die Gasgemische anhand ihrer Explosionsgruppe klassifiziert und zu jeder Gruppe die maximale Energie des Schlagvorgangs festgelegt, unter derer die Entstehung einer wirksamen Zündquelle als unwahrscheinlich angenommen werden kann.
Weitere Festlegungen von Grenzwerten für die kinetische Schlagenergie und geeignete Werkstoffpaarungen finden sich u.a. in der DIN EN 1755 (ex-geschützte Flurförderzeuge) und in der DIN EN 14986 (ex-geschützte Ventilatoren).
The main properties and main methods which are needed for the physico-chemical characterisation of graphene related 2D materials are discussed. As expample for standardization, protocols for the measurement of the chemical composition with XPS are discussed. The results of an interlaboratory comparisons led to new recommendations for the reliable measurments protocols.
Fire-induced spalling of normal strength concrete with different types of blended Portland cement
(2024)
The cement industry is looking to reduce its overall CO2 footprint. Greener manufacturing can be achieved by the introduction of more clinker-reduced cements. Concrete exposed to fire tends to show explosive spalling caused by thermomechanical and thermohydraulic processes. It is therefore essential to determine how concretes with clinker-reduced cements behave under fire exposure, especially for concretes containing calcined clays, as these are expected to be the supplementary cementitious material of the future. In this paper, normal strength concretes with four different cements (CEM I, CEM II/A-LL, CEM III/A and CEM II/B-Q) were examined for their fire-induced spalling behaviour. In addition, a mix with PP fibres was investigated for each concrete. The experiments were conducted on ring-restrained cylindrical specimens exposed to the hydrocarbon fire curve. The results showed that the cement type influences spalling behaviour. Samples with CEM I spalled the least, followed by CEM II/A-LL and CEM III/A. Finally, samples with CEM II/B-Q showed the most severe damage. It was found that the spalling behaviour of different concretes correlates with the moisture content before exposure to fire, meaning that higher moisture content leads to higher spalling susceptibility. The use of 2 kg/m³ PP fibres completely inhibited spalling regardless of the cement type used and therefore remains a successful avoidance strategy.
Graphene and related 2D materials (GR2Ms) are now entering an exciting phase of commercialization and use in products. Graphene nanoplatelets (GNPs) can be obtained in rather large quantities, but the properties of these industrially produced powders can vary depending on the production method, and even from batch to batch. Understanding and optimizing the surface chemistry of GNPs, modified through chemical functionalization processes is crucial, because it affects their dispersibility in solvents and matrices for the purpose of embedding them into real-world products. Therefore, reliable and repeatable measurements of the surface chemistry of functionalized GNPs are an important issue for suppliers as well as users of these materials. To address these concerns, international documentary ISO standards for measurement methodologies are under development which incorporate protocols that are becoming widely accepted in the community.
Recently, it was shown that pelletizing led to lower average O/C atomic ratios than those measured for powders [1]. In another study, the influence of the morphology on the degree of functionalization was shown [2]. As expected, a higher degree of functionalization was detected for smaller GNPs. The functionalization was located at the outermost surfaces of the GNPs by comparing experiments using photoelectron with soft (Al Kα, 1.486 keV) and hard X-rays (Cr Kα, 5.405 keV). Therefore, it is important for those using GNPs to understand both the physical and chemical properties of these particles, when considering their use in different applications.
The next step for reliable characterization protocols was the realization of an interlaboratory comparison under the auspices of VAMAS (Versailles Project on Advanced Materials and Standards) with 22 participating laboratories from all over the world. Samples of oxygen-, nitrogen-, and fluorine- functionalized GNPs were provided to the participants along with a measurement protocol. Participants were asked to prepare the samples as powders on a tape, powders in a sample holder recess, or as pellets. The lower measured O/C ratio reported for pelletized samples [1] was confirmed. The lowest scattering of the results was observed for the powders measured in the recess (Fig. 1). Furthermore, an influence of the humidity on the results was observed.
Interlaboratory comparisons (ILCs) are an important tool for the validation of characterisation methods, and, herwith, a prerequisite for standardisation. The "Versailles Project on Advanced Materials and Standards" offers a framework for performing such ILCs: (i) TiO2 nanoparticles using ToF-SIMS, and (ii) the chemical composition of functionalized graphene using XPS. The results of both ILCs underline the importance of sample preparation for the measured results.
Wir stellen unseren Ansatz und unsere Methodik zur Simulation von Piping-Erosion vor, welche während des Installationsprozesses von Suction Bucket Fundamenten für Offshore-Windkraftanlagen auftreten kann und ein kritisches Versagen des Installationsprozesses darstellt. Wir zeigen die Ergebnisse mehrere Simulationen und analysieren die hydrodynamischen und Kontaktkräfte, die auf das granulare Medium wirken, sowie die Druckdifferenz der flüssigen Phase. Solche Simulationen können zum besseren Verständnis von Piping-Erosion und letztendlich zu dessen Verhinderung beitragen.
Transportierbarkeit von Transport- und Lagerbehältern für radioaktive Stoffe, welche nach eine längerfristigen trockenen Zwischenlagerung
transportiert werden müssen. Überblick über die aktuellen Regelwerke und Richtlinien sowie die Zeitpläne für das Finden eines Endlagers für hochradioaktive Stoffe und die damit verbundene verlängerte Zwischenlagerung. Des Weiteren werden das für die verlängerte Zwischenlagerung notwendige Alterungsmanagement und die noch erforderlichen Forschungstätigkeiten vorgestellt.
Transportierbarkeit von Transport- und Lagerbehältern für radioaktive Stoffe, welche nach eine längerfristigen trockenen Zwischenlagerung
transportiert werden müssen. Überblick über die aktuellen Regelwerke und Richtlinien sowie die Zeitpläne für das Finden eines Endlagers für hochradioaktive Stoffe und die damit verbundene verlängerte Zwischenlagerung. Des Weiteren werden das für die verlängerte Zwischenlagerung notwendige Alterungsmanagement und die noch erforderlichen Forschungstätigkeiten vorgestellt.
Optical measurements of scattering luminescent materials dispersed in liquid and solid matrices and luminescent powders play an important role in fundamental research and industry. Typical examples are luminescent nano- and microparticles and phosphors of different composition in different matrices or incorporated into ceramics with applications in energy conversion, solid-state lighting, medical diagnostics, and security barcoding. The key parameter for the performance of these materials is the photoluminescence quantum yield QY, i.e., the number of emitted photons per number of absorbed photons. QY of transparent luminophore solutions can be determined relatively to a fluorescence quantum yield standard of known QY. Such standards are meanwhile available as certified reference materials.[1] The determination of QY of scattering liquid and solid samples like dispersions of luminescent nanoparticles, solid phosphors, and optoceramics requires, however, absolute measurements with an integrating sphere setup. Although the importance of reliable absolute QY measurements has been recognized, no interlaboratory comparisons (ILCs) on measurement uncertainties and the identification of typical sources of uncertainty have been yet reported. Also, no scattering reference materials with known QY are available.
We present here the results of a first ILC of 3 laboratories from academia and industry performed to identify and quantify sources of uncertainty of absolute QY measurements of scattering samples. Thereby, two types of commercial stand-alone integrating sphere setups with different illumination and detection geometries were utilized for measuring QY of transparent and scattering dye solutions and solid phosphors. As representative and industrially relevant solid and scattering samples, YAG:Ce optoceramics of varying surface roughness were chosen, applied, e.g., as converter materials for blue light emitting diodes. Special emphasis was dedicated to the influence of the measurement geometry, the optical properties of the blank, utilized to determine the number of photons of the incident excitation light absorbed by the sample, and the sample-specific surface roughness. While matching QY values could be obtained for transparent dye solutions and scattering dispersions, here using a blank with scattering properties closely matching those of the sample, QY measurements of optoceramic samples with different blanks revealed substantial differences, with the blank's optical
properties accounting for measurement uncertainties of more than 20 %. Based upon the ILC results, we recommend non-absorbing blank materials with a high reflectivity (>95 %) such as a 2 mm-thick PTFE target placed on the sample holder which reveals a near-Lambertian light scattering behavior, yielding a homogeneous light distribution within the integrating sphere.
Ausgehend von den Grundlagen der Korrosion stellt der Vortrag die Möglichkeiten des Korrosionsschutzes mit Zink vor. Dabei wird sowohl auf den kathodische Korrosionsschutz mit aktiven Zink-Anoden, als auch auf den Korrosionsschutz durch Deckschichtbildung an Zink und Zinküberzügen eingegangen. Veränderte Umweltbedingungen in Europa in den letzten Jahrzehnten, ermöglichen mit Schichtdicken um 80 µm einen Korrosionsschutz von über 100 Jahren, wenn konstruktive Randbedingungen beachtet werden.
Characterization and quantification of functional groups and coatings on nanoobjects an overview
(2024)
Characterization of Nanoparticles – Questions to Ask, Functional Nanoparticles (NPs) – Organic, Inorganic, and Hybrid Nanoparticles Nanomaterial Characterization Standardization – Addressing Remaining Gaps Surface FGs Particle Surface Chemistry - Why is it Important? Particle Surface Chemistry - A Key Driver for Performance, Applications, and Safety Aspects Method Development for Quantifying FGs and Ligands on Particle Surfaces FG Quantification – Method Choice & Criteria Relevant for Data Interpretation Quantifying the Amount of Total and Accessible FGs on Aminated Silica Nanoparticles (SiO2-NH2) Comparing the Total and Accessible –NH2 Content on Aminated Silica NPs of Different Size Characterization of Nanoparticles Standardization Standardized Measurements of Surface FGs on Nanoparticles EMP Project SMURFnano EMP Project SMURFnano Work Packages & Goals Certified Reference Materials from BAM
Wasserstoff als Energieträger gewinnt zunehmend an Bedeutung. Die Untersuchung von Störfallauswirkungen mit Wasserstoff rückt somit stärker in den Fokus. Da Wasserstoff meist unter Druck gelagert und transportiert wird, ist ein zu betrachtendes Szenario die Freisetzung aus einer Leckage mit anschließender Zündung. Die daraus resultierende Freistrahlflamme (Jet Flame) muss hinsichtlich der in die Umgebung emittierten Wärmestrahlung charakterisiert werden. In der Literatur existieren bereits verschiedene Modelle ([1], [2]), welche jedoch vermehrt auf Daten aus Kohlenwasserstoffflammen mit geringem Impuls basieren. Zur Überprüfung dieser Modelle wird im Zuge des BAM internen H2 Jet Flame Projektes die sicherheitstechnische Untersuchung von impulsbehafteten Wasserstoff Freistrahlflammen vorgenommen. Hierfür finden Versuche im Realmaßstab auf dem Testgelände Technische Sicherheit der BAM (BAM-TTS) statt. Gegenstand der Untersuchungen ist die Beurteilung der Auswirkungen von realistischen Freisetzungsszenarien hinsichtlich der Flammengeometrie und der freigesetzten Wärmestrahlung. Dabei werden Parameter wie Freisetzungswinkel, Leckagedurchmesser (z.Zt. 1 mm bis 10 mm), Druck (z.Zt. bis max. 250 bar) und Massenstrom (bis max. 0,5 kg/s) variiert. Zusätzlich können auch Einflüsse wie Art der Zündung, Zündort sowie Zündung mit zeitlichem Verzug untersucht werden. Gewonnene Erkenntnisse werden mit den Ergebnissen bereits vorhandener Modelle verglichen und diese im Bedarfsfall weiterentwickelt. Insbesondere wird der Fokus auf die Modellierung der freigesetzten Wärmestrahlung von Wasserstoffflammen gelegt. Herausforderung dabei stellt die IR-Vermessung und Modellierung von Sichtmodellen der Flammen dar. Die Visualisierung der Flammengeometrie wird mit Hilfe mehrerer Infrarot Kamerasystemen (aus mindestens zwei Blickwinkeln) vorgenommen.
Bisherige Messungen, die in der Literatur zu finden sind, basieren meist auf instationären Auströmbedingungen. Der hier verwendete Versuchsaufbau ermöglicht ein stationäres Ausströmen für mehrere Minuten und somit eine direkte Vergleichbarkeit mit den existierenden (stationären) Modellen.
Weiterhin ist der Versuchsstand umrüstbar für Vergleichsmessungen mit Kohlenwasserstoffen (Methan etc.) sowie Mischungen aus Wasserstoff und Kohlenwasserstoffen.
For industrial applications dealing with hydrogen, the definition of safety distances and the assessment of possible hazards emanating from releases is mandatory. Since hydrogen is usually stored and transported under pressure, one scenario to be considered is the momentum driven release of hydrogen from a leakage with subsequent ignition. In this scenario, the emitted heat radiation from the resulting jet flame to the surroundings has to be determined to define adequate safety distances. For hydrocarbon flames, different jet flame models are available to assess the hazards resulting from an ignited jet release. Since hydrogen flames differ from hydrocarbon flames in their combustion behavior, it has to be checked if these models are also applicable for hydrogen. To evaluate the accuracy of these models for hydrogen jet flames, tests at real-scale are carried out at the BAM Test Site for Technical Safety (BAM-TTS). Herein, the flame geometry and the heat radiation at defined locations in the surroundings are recorded for varying release parameters such as leakage diameter (currently up to 30 mm), release pressure (currently up to max. 250 bar) and mass flow (up to max. 0.5 kg/s). The challenge here is the characterization of the flame geometry in an open environment and its impact on the thermal radiation. Existing heat radiation data from the literature are mostly based on unsteady outflow conditions. For a better comparability with the steady state jet flame models, the experiments presented here are focused on ensuring a constant mass flow over the release duration to obtain a (quasi) stationary jet flame. In addition, stationary outflow tests with hydrocarbons (methane) were also carried out, which are intended to serve as reference tests for checking flame models based on hydrocarbon data.
Cryogenic liquefied gases, such as liquid hydrogen (LH2) and liquefied natural gas (LNG), are becoming more popular as eco-friendly energy sources. However, using these gases more often increases the risk of accidents, making it important to conduct thorough risk assessments. The storage systems for these gases rely on thermal superinsulation (TSI), which can fail under extreme heat, especially during fires. Therefore, it is essential to study how and why TSI fails. This research (part of PhD topic) aims to examine insulation performance, thereby improving the overall safety of cryogenic storage systems.
An overview with the basics of size and shape measurement of particles and 2D structures according to established methodologies (and popular imaging processing software packages) with imaging techniques is given. Main descriptors are explained based on practical cases are determined interactively at the flipchart.
To reduce carbon dioxide emissions, energy carries such as hydrogen consider to be a solution. Consumption of hydrogen as a fuel meets several restrictions such as its low volumetric energy density in gas phase. To tackle this problem, storage as well as transportation in liquid phase is recommended. To be able to handle this component in liquid phase, an efficient thermal insulation e.g., MLI insulation is required. Some studies have been revealed vulnerability of this type of insulation against high heat flux, for instance a fire accident. Some investigations have been depicted the importance of consideration of the MLI thermal degradation in terms of its reflective layer. However, limited number of studies have been focused on the thermal degradation of spacer material and its effect on the overall heat flux.
In this study, through systematic experimental measurements, the effect of thermal loads on glass fleece, glass paper as well as polyester spacers are investigated. The results are reported in various temperature and heat flux profiles. Interpreting the temperature profiles revealed as the number of spacers in the medium increases, the peak temperature detectable by the temperature sensor on the measurement plate decreases. Moreover, the contribution of each individual spacer in all cases regarding the experimental temperature range is assessed to be around 8%. This value may increase to around 50% for glass paper and polyester spacers, and to around 25% for glass fleece spacers as the number of spacer layers increases up to six layers.
To utilize the outcomes of the experiment later and integrate the results into numerical and CFD simulations, a model is proposed for the mentioned experimental temperature range up to 300°C to predict a heat flux attenuation factor. The model proposes a fitting factor that can reproduce the least square fitted line to the experimental data.