Trace element concentrations in gold grains from various geological units in South Africa were measured in situ by field emission-electron probe microanalysis (FE-EPMA), laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) and synchrotron micro X-ray fluorescence spectroscopy (SR-µ-XRF). This study assesses the accuracy, precision and detection limits of these mostly non-destructive analytical methods using certified reference materials and discusses their application in natural sample measurement. FE-EPMA point analyses yielded reproducible and discernible concentrations for Au and trace concentrations of S, Cu, Ti, Hg, Fe and Ni, with detection limits well below the actual concentrations in the gold. LA-ICP-MS analyses required larger gold particles (> 60 µm) to avoid contamination during measurement. Elements that measured above detection limits included Ag, Cu, Ti, Fe, Pt, Pd, Mn, Cr, Ni, Sn, Hg, Pb, As and Te, which can be used for geochemical characterisation and gold fingerprinting. Although LA-ICP-MS measurements had lower detection limits, precision was lower than FE-EPMA and SR-µ-XRF. The higher variability in absolute values measured by LA-ICP-MS, possibly due to micro-inclusions, had to be critically assessed. Non-destructive point analyses of gold alloys by SR-µ-XRF revealed Ag, Fe, Cu, Ni, Pb, Ti, Sb, U, Cr, Co, As, Y and Zr in the various gold samples. Detection limits were mostly lower than those for elements measured by FE-EPMA, but higher than those for elements measured by LA-ICP-MS.
For ten years µ-XRF (micro-focus X-ray fluorescence) analysis has been performed with SEM/EDS (scanning electron microscope with an energy dispersive X-ray detector) so that non-destructive analysis of elements at trace level concentrations below 100 µg g-1 becomes possible. This can be considered as a valuable completion of the classical electron probe microanalysis by EDS, an analytical method 'suffering' from rather poor limits of detection in the range of one to two orders of magnitude higher than those of µ-XRF. Based on a representative actual application, namely analysis of RoHS relevant elements at trace concentration levels, the performance of the rather new analytical method with respect to its limits of detection is systematically evaluated. CRMs (certified reference materials) specially prepared to support the quantitative XRF analysis of RoHS relevant elements were employed. On the other side, based on calculations of µ-XRF spectra according to a recently developed physical model the optimization of the analytical performance is also successfully undertaken.
In this study, we address the question of the
provenance and origin of the Dead Sea Scrolls manuscripts.
A characteristic low ratio of chlorine to bromine, corresponding
to that of the Dead Sea water, may serve as an indicator for
local production. For this aim we developed a non-destructive
procedure to determine the Cl/Br ratio in the parchment of
these manuscripts. Micro-X-ray fluorescence (µ-XRF) measurements
of a large number of parchment and leather
fragments from the Dead Sea Scrolls were analyzed with a
routine we developed based on fundamental parameter
quantification. This routine takes into account the absorption
of the collagen matrix and the influence of the different sample
thicknesses. To calculate the representative Cl/Br ratio for each
fragment, we investigated the lateral homogeneity and
determined the total mass deposition using the intensity of
the inelastically scattered, characteristic tube radiation. The
distribution of the Cl/Br ratios thus obtained from the µ-XRF
measurements make it possible to distinguish fragments
whose origin lies within the Dead Sea region from those
produced in other locations.
The resource-saving utilisation of recovered
waste wood is a matter of growing concern. In several
European countries, this utilisation is governed by regulations
and is dependent on the contents of certain trace
elements and organic compounds. Thus, for decisionmaking
with respect to waste wood management (recycling
or combustion), reliable analytical data are needed and, due
to their great economic and environmental impact, must be
assured by appropriate quality control. To support the
improvement in quality assurance in waste wood analysis,
for the first time, a wood reference material was certified
for its mass fractions of arsenic, cadmium, chromium,
copper, lead, mercury, and pentachlorophenol (PCP).
These analytes were selected because they represent typical
constituents of wood preservatives most widely used in the
past. Material preparation and testing of homogeneity and
stability were carried out by BAM Federal Institute for
Materials Research and Testing. The certification measurements
were performed involving selected laboratories
with documented expertise in the field of waste wood
analysis. The certified values and their corresponding
uncertainties were assigned in full compliance with the
requirements of ISO Guide 35. The certified mass fractions
and their expanded uncertainties (k/i> = 2) are as follows:
(3.1 ± 0.5) mg/kg for As, (3.02 ± 0.24) mg/kg for Cd,
(36.4 ± 2.6) mg/kg for Cr, (22.9 ± 1.7) mg/kg for Cu,
(0.60 ± 0.14) mg/kg for Hg, (39 ± 4) mg/kg for Pb, and
(7.9 ± 0.6) mg/kg for PCP. The certified material is
available as European Reference Material ERM®-CD100.
Measuring in a non-destructive way the characteristic trace elements of the metal allows following the circulation of gold in the past. The aim of this work is to probe the possibilities of X-ray fluorescence with high energy synchrotron radiation (SR-XRF) at the BAMline at BESSY II to determine the concentration of Pt in ancient gold alloys. A HP-Ge detector was used to measure the Pt K-lines excited with an incident energy of 79.5 keV. Data processing was done by subtraction of a Pt free gold standard spectrum from the spectrum of the sample. Depending on the sample composition, the MDL ranges between 40 and 90 ppm. The first results obtained for a small set of gold alloys of different thickness, size and composition showed that high energy SR-XRF is a significant method for the non-destructive determination of Pt in gold.