Ammonia Safety
(2023)
Ammonia is an energy source that has been produced and used on a large scale for many decades, primarily as a fertilizer or feedstock in nitrogen chemistry. The CAMPFIRE alliance, founded as part of the "WIR!- Wandel durch Innovation in der Region" funding program of the German Federal Ministry of Education and Research (BMBF), aims to research and develop new energy conversion and storage technologies for the future energy system based on green ammonia. The safe handling of ammonia is an important issue along the entire value chain. Therefore, the alliance has organized a webinar to discuss the topic of ammonia safety and in particular its flammability. BAM's contribution presented the topic of flammability in detail, placed the classification of ammonia in an international, European and national context and presented the basic principles of explosion protection that result from this and must be observed during use and application.
Polyamide 4.6 (PA46) is a high-heat-resistant polymer, but it has no dripping resistance under fire. Three commercial grades of PA46 are investigated under UL 94 vertical fire test conditions. Their performances are discussed based on the materials’ structural, thermal, and rheological properties. PA46 presents flaming drops, whereas dripping is prevented in the flame-retarded PA46.
Friction-modified PA46 has increased flaming dripping. Temperature profiles of the specimens under fire and the temperature of the drops are measured by thermocouples. A UL 94 vertical test configuration consisting of two flame applications is designed to assess the quantitative dripping behavior of the set of materials by the particle finite element method (PFEM). Polymer properties (activation energy and Arrhenius coefficient of decomposition, char yield, density, effective heat of combustion, heat of decomposition, specific heat capacity, and thermal conductivity) in addition to rheological responses in high temperatures are estimated and measured as input parameters for the simulations. The dripping behavior obtained by simulated materials corresponds with the experimental results in terms of time and drop size. A consistent picture of the interplay of the different phenomena controlling dripping under fire appears to deliver a better understanding of the role of different materials’ properties
Only the nano-scaled structure of the nanocomposite and the dispersion of nanoparticles within the polymer matrix harbor multifunctional potential including superior fire retardancy. Thus, this chapter focuses on the dispersion of nanoplates, based mainly on studies of layered silicates and graphene/graphene-related nanoplates. The nanostructure and properties of the nanocomposites are dependent mainly on thermodynamic and kinetic factors during preparation. Improving nano-dispersion often directly improves flame retardancy. Therefore, the modification of the nanoplates as well as the preparation of nanocomposites becomes very important to control this dispersion. The dispersion of nanoplates functions as a prerequisite for the formation of an efficient protective layer, changing the melt flow and dripping behavior, or the improvement of the char properties.
Fire resistance of fiber-reinforced polymers (FRPs) has been an important area of research for many years since FRPs are mainly used in the transportation and construction sectors. This study presents the fire behavior, and mechanical performance between the flame retarded pure epoxy resin and flame retarded glass-fiber composites before, during, and after a fire event. This enables a deeper understanding of the transferability of flame retardants on composite materials.
The influence of pressure sensitive adhesive (PSA) tapes as adhesive layers on the burning behaviour of bonded materials has been investigated. Single-sided tapes as an outer connection between construction materials have large influence on flammability, flame spread and fire resistance. In contrast, double sided tapes only take a small impact on the flammability but can drasticly change the burning behaviour in developing fires.
In this study, experimental determination and modelling investigations for the explosion regions of 1,3-dioxolane/inert gas/N2O and 1,3-dioxolane/inert gas/air mixtures were carried out and compared. The experimental measurements were carried out at 338 K and atmospheric pressure according to EN1839 method T using the inert gases N2, CO2, He and Ar. The results showed that the ratio of the lower explosion limit in N2O (LELN2O) to the lower explosion limit in air (LELair) is 0.52 and the ratio of the maximum oxygen content in air (MOCair) to the limiting oxidizer fraction in nitrous oxide (LOFN2O) is 0.36 ± 0.02 independent of the inert gas. When comparing the inert gas amount at the apex based on the pure oxidizing component, which is O2 in case of air, N2O-containing mixtures need less inert gas to reach the limiting oxidizer quantity whereas the efficiency of inert gases is in the same order. The coefficients of nitrogen equivalency however were found to differ to some extent. The explosion regions of 1,3-dioxolane/inert gas/oxidizer mixtures were modelled using the calculated adiabatic flame temperature profile (CAFTP) method as well as corrected adiabatic flame temperatures. The results indicate good agreement with experimental data for CO2, N2 and Ar- containing mixtures. The noticeable deviations that occur when He is the inert gas are due to the lacking transport data of that mixture.
Polyurethanes (PU) represent one of the most versatile classes of plastics. They are processed and used as thermoplastic, elastomer, and thermoset. The requirements regarding flammability are correspondingly versatile. Depending on the material and the field of application, specific fire tests have to be fulfilled. This paper describes the different concepts used to fulfil these requirements by choosing the right raw materials and flame retardants.
Flame retarded polymeric materials are used in various applications in which a certain fire behavior is demanded. Protection goals are defined, such as limited flammability in terms of hindered sustained ignition or limited contribution to a fire, and these protection levels are tested with defined specimens or components in defined fire scenarios, that is to say, different fire tests. Passing a specific fire test by meeting whatever its demands is often the most important development goal, so the parameters of the different fire tests vary widely to emphasize different fire properties. Some fire tests are used to screen or provide a general assessment of flame retardant polymers during development, while other fire tests and tailored experiments are performed to address special phenomena or understand the flame retardancy modes of action. For all fire testing, the devil is in the details – demanding know-how and crucial efforts to manage the quality of investigations and advanced interpretation. This chapter aims to offer a structured overview of all these aspects.
Most fluorinated hydrocarbons that shall replace refrigerants with high GWP, like R134a, are flammable. For evaluating inertization measures for explosion protection, flammability of low-GWP refrigerants R1234yf, R32 and R1132a blended with carbon dioxide, nitrogen and argon were studied experimentally in a closed autoclave at atmospheric conditions. Furthermore, a calculation method was adapted to reduce the experimental costs for flammability studies on these gas mixtures. For igniting R1234yf in the closed autoclave a newly developed ignition system was used that allows generating electric arcs with high ignition energy. Gas mixtures containing the mildly flammable R1234yf and R32 could be inerted by adding much less inert gas than mixtures containing R1132a, which is more similar to unfluorinated hydrocarbons regarding the explosion regions. By using the adapted model of constant adiabatic flame temperature profiles estimating the explosion limits of fluorinated hydrocarbons was possible with similar accuracy as for unfluorinated hydrocarbons.
Keywords: Explosion Protection, Inertization, Flammability, HFOs, HFC., R1234yf, R32, R1132a
The paper provides a summary of safety characteristics of hydrogen and hydrogen fuel gases. The inves-tigations focus on water electrolysis, the feeding of hydrogen into the natural gas grid and the use ofhydrogen for the fermentation process in biogas plants. The safety characteristics of hydrogen such as avery low minimum ignition energy, very large explosion range and high flame velocity with the resultingrapid pressure increase of hydrogen explosions are of particular importance for explosion protection andthey differ strongly from those of natural gas. Explosion ranges of hydrogen-methane-carbon dioxidemixtures have been measured for the use of hydrogen in biomethane production. The paper also showsand discusses explosion ranges of hydrogen and hydrogen-natural gas mixtures. Pressure and tempera-ture dependencies of the explosion limits of mixtures were investigated. Furthermore, pressure rise rates(KGvalues) were measured with regard to constructive explosion protection. The maximum experimen-tal safe gaps were determined for the classification of the mixtures and assignment to explosion groupsaccording to the European ATEX directives. It was found that admixture of 10% hydrogen to natural gashas only a minor influence on the safety characteristics of gas explosions.
Flame-retarded biocomposites of thermoplastic starch and natural fibres are successfully processed according to state-of-the-art extrusion and injection moulding. Using agave fibres and henequen fibres recovered from local industrial waste is a convincing contribution to sustainability. A systematically varied set of biocomposites is investigated comprehensively, e.g. electron microscopy is used for characterizing the morphology, rheology for the melt viscosity, tensile and impact resistance for the mechanical properties, thermal analysis for the pyrolysis, UL 94 burning chamber and oxygen index for the flammability, and cone calorimeter for the fire behaviour. Achieving sufficient mechanical properties was not the goal in our pre-competitive study but may be tackled by adding compatibilizer in future. The combination of well-dispersed natural fibres, aluminium diethylphosphinate (AlPi) and a special silicone synergist (Si) is proposed as promising innovative route for V-classified biocomposites. The flame-retardancy modes of action in the gas phase (fuel dilution and flame inhibition) and in the condensed phase (charring, protective layer formation) are discussed in detail, as is the role of combining the ingredients. This work is a convincing proof of principle of how to prepare industrial-waste fibres biocomposites, to apply the synergistic combination of AlPi and Si for future flame-retarded technical polymer materials that are based on renewable resources and compostable.
This paper is based mainly on the results of two different projects performed in the group of the author recently (2016-2019). The three external partners involved in these two projects are competent in the preparation of FPUF (ICL IP America), RPUF (Department of Industrial Engineering, Padova University), and TPU (Fraunhofer-Institut für Betriebsfestigkeit und Systemzuverlässigkeit LBF, Darmstadt) as well as for the specimen preparation. Systematically varied sets of materials were prepared as the key basic for scientific discussion, varying the kind and combination of flame retardant, PUR structure, density, and blowing agent.
A multimethodical approach based on thermogravimetry (TGA), TGA coupled with evolved gas analysis (TGA-FTIR) and pyrolysis GC-MS was used for investigating the pyrolysis. The flammability was addressed using oxygen index (OI) and testing in UL 94 burning chamber in vertical and horizontal set-up. The fire behaviour was addressed by using a cone calorimeter. Beyond these methods according to the state of the art, key experiments were performed. We addressed the dripping and the two-stage burning of TPU using a self-designed apparatus and specific data evaluation, the foam burning through quenching burning samples, using different special sample holders, and measuring temperature profiles within the burning foams. The investigation is made round by intensive analysis of the fire residues, such as comprehensive investigation of the morphology.
Result on the pyrolysis (TGA-FTIR, Pyrolysis-GC/MS), flammability (UL 94, LOI), and fire behaviour (cone calorimeter) of TPU and flame retardant TPUs are shown. We discuss in detail the characteristic of PUR decomposition: the low tendency to char, and the specific two step decomposition and how these characteristics control the regimes in fire behaviour. We demonstrate that the different burning regimes are controlled by different pyrolysis products and effective heat of combustions. The resulting formation of pool fires as well as the formation of dripping is discussed in detail. The latter quite important to understand the flame retardancy applied with respect to achieve the UL 94 classification V0 nondripping or V0 non-flaming dripping.
Rigid and flexible PUR foams and their flame retarded versions are investigated for different densities. Water and pentane-blown foams are compared as well as PUR and polyisocyanurate-polyurethane (PIR) foams. Horizontal testing in the cone calorimeter is used and the vertical foam specimen holder as well. Self-designed set-ups within the cone calorimeter enable a better inside in the pyrolysis front running through the foam samples as well as the development of the temperature gradient inside the foam during the fire test. The morphology change during burning was characterised by the means of quenching burning foams with liquid nitrogen and investigating the cross sections with scanning electron microscope. In sum, a rather comprehensive study was performed to work out the principle fire phenomena controlling the fire behaviour of PUR foams in a very systematic and significant way.
Promising flame retardancy approaches are discussed. The importance of either combining the drain of fuel and flame inhibition or charring into an effective protection layer/multicellular structure is underlined.
This contribution focusses the general conclusions and trends. It tries to increase the understanding of the specific and demanding challenge to develop flame retardant PUR materials.
Nowadays, various polymeric materials are used in E&E applications with sufficient flame retardance by adding rather different flame retardants. It doesn’t matter whether cables are used outdoor or are installed indoor as building products, the weathering exposures such as UV radiation, humidity and variation in temperature occur and influence the flame-retardant property. Recently, the lifetime of the flame retardance itself becomes an increasingly important factor. In this work, several devices were used to perform accelerated artificial ageing simulating different environment exposures.
The comprehensive and global understanding of the durability of flame retardance in dependence on the weathering or ageing conditions is still a matter of discussion. Therefore, the weathering resistance of various halogen-free fire-retarded polymers was investigated in this work. Polymeric systems with different kinds of fire retardants were chosen, including various fire retardant mechanisms. Ethylene Vinyl Acetate (EVA) blends with high amounts of inorganic flame retardant such as aluminum hydroxide (ATH), boehmite and synergists, which mainly dilutes the polymer resin work as heat sink and cooling agent, and enhance residue formation was examined. Thermoplastic Polyurethane (TPU) was modified with melamine cyanurate (MC), which mainly acts by changed melt flow and dripping behavior as well as fuel dilution. Additionally, aluminum diethylphosphinate and boehmite are induced as assistant flame retardant. Furthermore, glass fiber reinforced Polyamide 66 (PA) was investigated containing different kinds of aluminum diethylphosphinate based flame retardant mixtures, which acts by flame inhibition and additional char formation.
The degradation of the surface was analyzed after the different weathering conditions. Most of the specimens exhibited an intensive material degradation at the top surface accompanied by a distinct discoloration, e.g. getting darker or showing yellowing. The weathering of the EVA samples lead to numerous cracks (already) after 4000 h. The corresponding changes in the chemical structure was investigated by ATR FT-IR for all materials.
The flammability was investigated by cone calorimeter, UL-94 burning chamber, and oxygen index (LOI) using plate and bar specimens. The flame retardance of most of the materials studied degrades only slightly or were rather stable for the investigated exposure times. Interestingly, also some opposite results were found. EVA modified by different inorganic flame retardants such as ATH achieved higher LOI after exposing in the humidity chamber and the accelerated oxidation under water in the autoclaves. It is suggested that the particle size of ATH and boehmite plays an important role, when these flame retardants agglomerate at the surface during accelerated weathering.
Both materials, EVA and TPU, were also investigated as cable jackets. While EVA modified with inorganic flame retardants exhibits low-smoke and non-dripping fire behavior, TPU flame-retarded with MC yields cables with pronounced melt-dripping. Cone calorimeter tests were carried out using cable rafts of the size of 100 mm * 100 mm as well as our self-made cable module test, which simulates the vertical full-scale test of a bundle of cables at the bench-scale. Both methods were used to investigate the weathering resistance of the flame retardance in cables. The results of the cable module test for the flame-retarded EVA cables were only slightly affected even when a long time hydrothermal ageing was carried out. This is because of inorganic residue which just delays the fire growth but does not extinguish. However, for the flame-retarded TPU cable jackets, the cable module test exhibited an accelerated fire spread and a melt-dripping behavior which was promoted by weathering exposure.
Developing halogen‐free flame retardants with reasonably high efficiency, which thus function at limited loadings in polypropylene‐based wood/plastic composites (WPC), is still a challenge. Cost‐effective flame‐retarded WPC have been identified as a way to open the door to an interesting, broader spectrum of application in the building and transportation sectors. This work imparts a systematic comprehensive understanding and assessment of different basic routes to halogen‐free flame‐retarded WPC, taking into account economic and environmental considerations. Cheap, halogen‐free single‐component flame retardants and their multicomponent systems are investigated at reasonable filling grades of 20 wt%. The basic routes of promising synergistic multicomponent systems are discussed, and their potential and Limits assessed. Optimizing the consistency of fire residue; closing the surface of inorganic‐organic residual layers; the thermal stabilization and design of the residue, eg, synergistic combination of ammonium polyphosphate and expandable graphite; and the combination of different flame‐retardant mechanisms, eg, intumescence and flame inhibition, are proposed as promising routes to boost the flame‐retardant efficiency.
Rigid polyurethane foams (RPUFs) typically exhibit low thermal inertia, resulting in short ignition times and rapid flame spread. In this study, the fire phenomena of RPUFs were investigated using a multi-methodological approach to gain detailed insight into the fire behaviour of pentaneand water-blown polyurethane (PUR) as well as pentane-blown polyisocyanurate Polyurethane (PIR) foams with densities ranging from 30 to 100 kg/m3. Thermophysical properties were studied using thermogravimetry (TG); flammability and fire behaviour were investigated by means of the limiting oxygen index (LOI) and a cone calorimeter. Temperature development in burning cone calorimeter specimens was monitored with thermocouples inside the foam samples and visual investigation of quenched specimens’ cross sections gave insight into the morphological changes during burning. A comprehensive investigation is presented, illuminating the processes taking place during foam combustion. Cone calorimeter tests revealed that in-depth absorption of radiation is a significant factor in estimating the time to ignition. Cross sections examined with an electron scanning microscope (SEM) revealed a pyrolysis front with an intact foam structure underneath, and temperature measurement inside burning specimens indicated that, as foam density increased, their burning behaviour shifted towards that of solid materials. The superior fire performance of PIR foams was found to be based on the cellular structure, which is retained in the residue to some extent.
The individual and collective impacts of additives in melt dripping behaviour were studied under UL 94 vertical test conditions. A set of polyamide 6 (PA6) based materials compounded with melamine cyanurate (MCA) – a ˝dripping agent˝ – and glass fibre (GF) – a ˝non-dripping agent˝ - was investigated in detail. Dripping quantification was carried out during first and second ignition. The materials and their drops were investigated with respect to thermal decomposition, melt viscosity, and others properties. PA6 with V-2 classification improves to V-0 when MCA is added; and is worsened to HB in presence of glass fibre. Together, PA6/GF/MCA achieved V-2. The non-flaming drops of PA6/MCA are formed by oligomeric fragments. The flaming drops of PA6/GF contain a high amount of glass fibre. The dripping behaviour of PA6/GF/MCA under fire is a complex response of the specimen, but not explained by an easy superposition of the materials’ properties. The dripping behaviour is influenced by the interaction and concurrence of the different phenomena.
Thermoplastic starch polymer blends as biodegradable materials are well known and used mainly as packaging material. In order to exploit new application fields for these materials, additional properties such as flame retardancy or increased mechanical strength are required. This work focuses on the flammability and fire behavior of a thermoplastic starch/polyester blend reinforced with natural fibers derived from Mexican industry processes wastes, such as keratin fibers from the tannery industry or coconut fibers[1]. Different fiber contents as well as combinations of varying contents of aluminum trihydroxide, expandable graphite or ammonium polyphosphate were tested in LOI, UL94, cone calorimeter and TG-FTIR in order to investigate and assess the concentration dependence of the fibers and flame retardants as well as synergistic effects between both components. In combination with ammonium polyphosphate, the coconut fibers induce a synergistic effect by reinforcing the char residue and creating a more stable heat barrier during forced flaming combustion in the cone calorimeter. Synergism is also observed in the oxygen test. The recycling of otherwise wasted material is a true challenge in material development, thus this work is a first step in the direction of sustainable and biodegradable materials.
The fire behaviour of carbon fibre (CF) reinforced polymers differs in comparison to polymers. Fibres behave often inert with respect to pyrolysis, they change the melt flow and dripping behaviour, the heat absorption and transfer, the amount and properties of the fire residue and so on. Flame and fire retardancy concepts are needed not only suitable for the different fire protection goals typical for each application, but also tailored for composites. This field is illuminated by examples taken from different projects carried out in the group of the author in the recent years. The examples target on different applications through achieving reduction in reaction to fire controlling the fire risks (flammability, heat release) in the beginning and development of a fire and investigating the fire stability, when a severe flame is directly applied (key property in fully developed fires). Approaches to halogen-free flame retardancy in CF reinforced thermosets are presented as well as building up a bench and an intermediate scale testing of composites in fire applying mechanical load (up to 1 MN compression) and direct flame exposure (180 kW/m2) simultaneously. Indeed, e.g. we have investigated the fire stability of stringer reinforced shell components taken out from the fuselage of an aircraft.
The understanding of fire behaviour, fire resistance, and fire retardant modes of action in composites is a promising basis for target-oriented development. The role of flame inhibition, charring, and protective layer formation is discussed. Successful concepts are presented for fire retardancy tailored for different application as well as general guidelines for future development. Different phosphorus flame retardants are proposed to achieve halogen-free flame retardancy with respect to ignition and developing fires. Different protective approaches are sketched for addressing the fire stability of composites that is the most important fire risk for the fire resistance in structural applications.
ISO 10156:2010 contains a test method and a calculation method for flammability of gases and gas mixtures for the selection of cylinder valve outlets. The calculation method is used also to classify gas mixtures according to the national and international dangerous goods and dangerous substances regulations, e.g. according to the UN Recommendations on the Transport of Dangerous Goods (UN TDG) and the Globally Harmonized System of Classification and Labelling of Chemicals (UN GHS). The calculation method for gas mixtures requires substance parameters of the single components. These are the coefficients for the fire potential (Tci) and for inerting ability, the so-called nitrogen equivalence (Kk), which have been estimated conservatively by means of flammability data.
BAM checked Tci and Kk values of ISO 10156:1996 using three-component diagrams (Flammable gas-Inert-Air) of the CHEMSAFE® database. The experimental fundamentals and the principles of the calculation method are summarized in this paper. The revised data for Tci and Kk values were adopted in the tables of ISO 10156:2010.
Furthermore, subcategorization of flammable gases has been proposed by a UN working group and shall be implemented in the GHS in the meantime. The subcategorization requires the lower flammability limit (LFL) as an additional indicator. Therefore, a test method and a calculation method for LFL were proposed by BAM and have been implemented in the new draft of ISO/CD 10156:2016.
The calculation method for gas mixtures is based on Le Chatelier’s rule and was extended by using the Kk values for inert components in the mixture. The calculated LFLs of methane-inert gas mixtures were compared with experimental values for different types of inert gases. It could be shown that calculated LFLs are in good agreement with experimental values if the Kk values derived from three-component flammability diagrams are used. Although using the Kk values of ISO 10156:2010 leads to higher deviations, the results are still on the safe side.