Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (19822)
- Zeitschriftenartikel (17962)
- Posterpräsentation (6182)
- Beitrag zu einem Tagungsband (5996)
- Beitrag zu einem Sammelband (2316)
- Forschungsbericht (774)
- Sonstiges (393)
- Buchkapitel (356)
- Dissertation (299)
- Zeitschriftenheft (Herausgeberschaft für das komplette Heft) (261)
- Forschungsdatensatz (143)
- Newsletter (89)
- Video (66)
- Tagungsband (Herausgeberschaft für den kompletten Band) (50)
- Monografie (42)
- Handbuch (27)
- Sammelband (Herausgeberschaft für den kompletten Band) (24)
- Jahresbericht (21)
- Corrigendum (20)
- Amtliche Bekanntmachung (14)
- Habilitation (2)
Sprache
- Deutsch (30507)
- Englisch (24012)
- Mehrsprachig (193)
- Französisch (41)
- Russisch (31)
- Spanisch (21)
- Ungarisch (11)
- Tschechisch (7)
- Italienisch (7)
- Japanisch (5)
Schlagworte
- Korrosion (427)
- Corrosion (412)
- Concrete (391)
- Fluorescence (346)
- Nanoparticles (328)
- Additive manufacturing (294)
- Simulation (257)
- LIBS (250)
- Zerstörungsfreie Prüfung (250)
- XPS (231)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (2271)
- 6 Materialchemie (2232)
- 7 Bauwerkssicherheit (1795)
- 1 Analytische Chemie; Referenzmaterialien (1793)
- 9 Komponentensicherheit (1469)
- 4 Material und Umwelt (1105)
- 5 Werkstofftechnik (1079)
- 3 Gefahrgutumschließungen; Energiespeicher (813)
- 6.3 Strukturanalytik (625)
- 6.1 Oberflächen- und Dünnschichtanalyse (586)
Paper des Monats
- ja (97)
Silica materials are popular in biomedical applications as composites and drug delivery platforms due to their low toxicity and biocompatibility. Mesoporous silica nanoparticles are attractive drug delivery systems based on their porous silica framework with high surface area. In the preparation of mesoporous silica frameworks, most commonly, MCM-41, the efficient removal of the template responsible for introducing porous networks, cetyltrimethyl ammonium bromide (CTAB), is a critical step due to the template’s high toxicity in the environment and human health. In this work, we present a new one-pot approach of introducing challenging antibiotics within a silica framework without the need of toxic templates, but instead using micelle formation by an antibacterial agent. We demonstrate that micelles formed by cetylpyridinium chloride (CPC), a known antibacterial agent, entrap antibiotics such as rifampicin and ciprofloxacin. Extensive NMR studies elucidate the precise localisation of the antibiotic within the CPC micelle. Ciprofloxacin is placed between the outer and palisade region while rifampicin is located further into the hydrophobic CPC micelle core. In both cases, the formation of the silica framework can be built around the CPC-antibiotic loaded micelles. The resulting silica nanoparticles show loading of both CPC and antibiotic agents, porosity and dual antibacterial release upon disruption of the micelle within the silica framework. The design not only provides a strategy of a therapeutic design to form porous frameworks but also highlights the potential of precise antibiotic dose and release in nanoparticle systems.
Electromagnetic stirring is known to promote material flow, reduce porosity, uniform elements distribution, and refine grain in laser beam welding (LBW), which enhances the applicability of LBW in various industries. In this study, a phase-field model of dendrite growth in AA5754 Al alloy electromagnetic stirring laser beam welding was established. The model considered the thermal electromagnetic Lorentz force resulting from the interaction between the electric field generated by the Seebeck effect and the magnetic field, as well as the temperature gradient and solidification rate of the solidification interface obtained from the computational fluid dynamics electromagnetic stirring LBW model. The variation rules of dendrite growth with different magnetic parameters and effects are analyzed. Comprehensively, the magnetic field promotes the solidification rate, thus promoting interfacial instability and a large magnetic flux density leads to a faster interface instability. The solidification rate as well as the temperature gradient affect the growth rate, and the accelerated growth caused by the so lidification rate with a high frequency and a large magnetic flux density effectively inhibits the slow growth caused by the temperature gradient. The thermal electromagnetic Lorentz force is the main factor for the branch increment at low frequencies, while both thermal electromagnetic Lorentz force and temperature gradient in crease the number of branches at high frequencies. The calculated average branch numbers considering various factors in the stable stage under different magnetic parameters were consistent with the results of the scanning electron microscope tests.
The recommendation is based on the co-authors’ work organized by the RILEM TC 256-SPF “Spalling of concrete due to fire: testing and modelling”. It aims to provide useful information, guidance and best practices in fire spalling assessment to laboratories that perform large-scale tests based on fire resistance test standards. It provides guidance on the spalling observation techniques during testing, as well as post-test spalling quantification/assessment methods. This document is intended to be used in conjunction with the fire resistance test standards, e.g. EN 1363-1 and ISO 834-1.
Die zunehmende Anwendung hochfesten Betons in ermüdungsbelasteten Bauwerken, herausfordernde Belastungsszenarien im Bereich von On- und Offshore Windenergieanlagen bezüglich sehr hoher Lastwechselzahlen sowie das gleichzeitige Streben nach energie- und ressourcenschonendem Bauen stellen die Bemessung von Beton gegen Ermüdung vor neue Aufgaben. Eine Vielzahl von Studien beschreibt bereits die Auswirkung von Einflussfaktoren wie Mischungszusammensetzung, Feuchte, Probekörpergröße oder Belastungsart auf die Ermüdungsfestigkeit und den Ermüdungsprozess. Aufgrund der unterschiedlichen Geometrien und Mischungen der in den verschiedenen Studien verwendeten Proben sind die Auswirkungen der Einflussfaktoren jedoch kaum miteinander vergleichbar. In dem vom Bundesministerium für Wirtschaft und Klimaschutz (BMWK) geförderten Verbundprojekt WinConFat wurden deshalb verschiedene Einflussfaktoren gezielt an Proben mit einheitlichen Mischungen untersucht. Das durch die Bundesanstalt für Materialforschung und -prüfung (BAM) bearbeitete Teilprojekt fokussierte sich auf den „Einfluss der Probengeometrie und -größe auf die Ermüdung von Beton“. Neben der Erhebung von Daten zur Ermüdungsfestigkeit wurde der Ermüdungsprozess mit zerstörungsfreien Prüf- und Messmethoden untersucht. Diese Prüfmethoden wurden auch hinsichtlich ihrer Anwendbarkeit zur Erfassung der ermüdungsbedingten Schädigungsentwicklung an Betonbauwerken im Rahmen von Monitoringkonzepten bewertet. Untersucht wurden die Ermüdungsfestigkeiten und der Ermüdungsprozess an Zylindern mit drei unterschiedlichen Betonmischungen sowie unterschiedlicher Größe und Schlankheit. Die Ergebnisse dieser Untersuchungen werden im Folgenden vorgestellt und diskutiert.
Der Vortrag gibt einen Überblick über die vielfältigen Möglichkeiten der Oberflächenfunktionalisierung mittels Mikro- und Nanostrukturierung durch Ultrakurzpuls-Lasermaterialbeabeitung. Dies schließt eine Diskussion des Phänomens der Laser-induzierten periodischen Oberflächenstrukturen (LIPSS, engl.: Laser-induced Periodic Surface Structures, Ripples), sowie deren Klassifikation und Bildungsmechanismen mit ein. Ein Schwerpunkt der Präsentation liegt auf der Diskussion verschiedener Anwendungsmöglichkeiten der LIPSS in Bereichen der Optik, Fluidik, Tribologie und Medizin, sowie auf einem Ausblick auf die industrielle Skalierbarkeit der LIPSS-Technologie.
Interactions between a polymer and a substrate interface play a vital role in understanding the improvement in thin film material properties as well as serving as a model for nanocomposites. For any non-repulsive polymer-substrate interactions, polymer segments form an irreversibly adsorbed layer and show a slowdown in the glassy dynamics and thus an increase in the thermal glass transition temperature compared to the bulk-like values. The growth kinetics of the adsorbed layer showed a deviation for both poly (bisphenol-A carbonate) (PBAC) and polysulfone (PSU), two bulky polymers containing a functional group (phenyl ring) in the backbone.
Nanoparticles (NPs) are tiny – around 1 to 100 billionths of a meter – and can have different chemistries and behaviours than the same material of larger size. This property has led to advances in a wide range of industries, but it can also confer toxicity. Size measurements are the main way NPs are identified but a lack of standardised methods for identifying ones with complex shapes has hindered evaluation of their potential harm.
Wir präsentieren unsere Forschungsergebnisse zur Entwicklung eines faseroptischen Sensorsystems mit polymeroptischen Fasern integriert in Geokunststoffe für die Überwachung von geotechnischen Anlagen. Das Sensorsystem dient der räumlichen Auflösung lokaler Dehnungsereignisse im für Anwender signifikanten Größenordnungsbereich von 3 % bis 10 %. Das gesamte Sensorkonzept besteht aus einem praxistauglichen Messsystem basierend auf der digitalen inkohärenten optischen Frequenzbereichsreflektometrie (I-OFDR) und einer Sensormatte in Form eines Geotextils mit integrierten faseroptischen perfluorierten polymeroptischen Fasern (PF-POFs).
Biofuels, particularly biodiesel, have gained significant attention as an alternative to traditional fossil fuels in recent years. Unlike diesel, which contains hundreds of compounds, biodiesel only contains a few compounds in the C16-C18 carbon chain. However, the use of biodiesel in automobile and transportation applications can result in problems of degradation or even damage in materials. Among the commonly used polymer materials, fluorocarbon (FKM) shows excellent performance and high stability and compatibility towards oil, diesel, ethanol, and other chemicals. FKM is a family of fluorocarbon-based fluoroelastomer materials, which provide excellent high-temperature and chemical stability compared to other elastomers. As a result, FKM is widely used in chemical processes such as petroleum refining, where it is used for sealings, pumps, and other components.
Mechanical stress often accelerates the failure of polymer materials. The aim of this research is to study the interaction between the sealing material FKM and biofuels B10 (heating oil with 10% biodiesel). The mechanical stress test was carried out in a special apparatus. Both mechanical and non-mechanical stress tests were conducted on specimens at 20, 40, and 70 °C for 28 days to document changes in mass, volume, and tensile properties. Both increasing temperature and mechanical stress have a significant effect on the tensile strength of the FKM polymer when exposed to B10. The combination of increasing temperature and mechanical stress induced rupture within 2 h. It was also established that FKM polymer with pre-exposure in B10 survived longer during mechanical stress compared to specimens exposed only to air. With the support of infrared (IR) spectroscopy, we were able to confirm the penetration of B10 into the FKM polymer.
A method of solving the thermo-fluid dynamics problem is presented, enabling the prediction of the shape and dimensions of the weld pool during keyhole laser welding of thick plates. It is shown that the rear weld pool boundary can be satisfactorily approximated by a set of superellipses (Lamé curves). The presence of a convex rear weld pool boundary in the mid-plane has been observed experimentally and reproduced numerically. It was shown that in this zone the concentration of liquating impurities increases and the local solidification temperature decreases, contributing to the susceptibility to hot cracking.
Related work
Laboratory Study:
Combining Signal Features of Ground-Penetrating Radar to Classify Moisture Damage in Layered Building Floors
https://doi.org/10.3390/app11198820
On-Site Study:
TBA
Doctoral Thesis:
Non-destructive classification of moisture deterioration in layered building floors using ground penetrating radar
https://doi.org/10.14279/depositonce-19306
Measurement Parameters
The GPR measurements were carried out with the SIR 20 from GSSI and a 2 GHz antenna pair (bandwidth 1 GHz to 3 GHz) in common-offset configuration. Each B-Scan consists of N A-Scans, each including 512 samples of a 11 ns time window. Survey lines were recorded with 250 A-Scans/ meter, which equals a 4 mm spacing between each A-Scan No Gains were applied.
Folder Description:
Lab_dry, Lab_insulDamage, Lab_screedDamage
- each contain 168 Measurements (B-Scans) in .csv on 84 dry floors, floors with insulation damage and screed damage.
- each floor setup was measured twice on two orthogonal survey lines, indicated by _Line1_ and _Line2_ in the file name.
- the file names encode the building floor setup e.g. CT50XP100 describes a 50 mm cement screed with 100 mm extruded polystyrene below
- the material codes are
CT: cement screed, CA: anhydrite screed, EP: expanded polystyrene, XP: extruded polystyrene, GW: glass wool, PS: perlites
further information can be found in the publication https://doi.org/10.3390/app11198820
OnSite_
- 5 folders containing B-Scans on 5 different practical moisture damages
- the building floor setup is encoded according to the lab with an additional measurement point numbering at the start and a damage case annotation at the end of the file name with _dry, _insulationDamage and_screedDamage
File Description:
B-Scans, Measurement files - no header
- dimension: 512 x N data point with N beeing the number of A-Scans including 512 samples of a 11 ns time window.
- survey lines were recorded with 250 A-Scans/ meter, which equals a 4 mm spacing between each A-Scan
Moisture References
- Moist_Reference of On-Site Locations include the columns MeasPoint: Measurement point, wt%Screed: moisture content of screed layer in mass percent; wt%Insul: moisture content of insulation layer in mass percent. References were obtained by drilling cores with 68 mm diameter in the center of each survey line.
- Moist_Reference_Screed of Lab data include the columns Screed: Screed material and thickness in mm, wt%Screed moisture content of screed layer in mass percent
- Moist Reference_Insul of Lab data include the columns Insulation: Insulation material and thickness in mm, water addition in l: water added to the insulation layer in liters, V%Insulation: water added to the insulation layer in volume percent, RH%: resulting relative humidy in the insulation layer during measurement. These References are only avaible for Lab measurements on insulation damages.
A novel distributed acoustic sensing technique is proposed that exploits both phase and amplitude of the Rayleigh backscattered light to quantify the environmental variation. The system employs a wavelength-scanning laser and an imbalanced Mach-Zehnder interferometer to acquire the reflection spectra and the phase of the detected light, respectively. Fading-free and low-frequency measurements are realized via the crosscorrelation of the reflection spectra. The discrete crosscorrelation is used to circumvent the nonlinear frequency sweeping of the laser. Based on the phase of the backscattered light, it is possible to quantify fast environmental variations. The whole system requires no hardware modification of the existing system and its functionality is experimentally validated. The proposed system has the potential to monitor ground motion/movement at very low frequency band like subsidence around mining areas and at high frequency band like earthquakes and vibrations induced by avalanches.
A systematic, nature-inspired chemical engineering approach is employed to solve the issue of flooding in electrochemical devices. The mechanism of passive water transport utilized by lizards living in arid environments is leveraged to design flow-fields with a microchannel structure on their surface, through which capillary pressure rapidly removes the water generated in the electrochemical device. This water management strategy is implemented in proton exchange membrane fuel cells (PEMFCs) with a lunginspired flow-field, which ensures uniform distribution of reactants across the catalyst layer. Jointly, this nature-inspired approach results in flood-free, stable operation at 100% RH and a B60% increase in current (B1.9 A cm-2) and peak power density (B650 mW cm−2) compared to current PEMFCs with a flood-prone, serpentine flow-field (B0.8 A cm-2 and 280 mW cm-2, respectively). This significant advance allows for PEMFC operation at fully humidified conditions.
BAM Inside #1/2024
(2024)
BAM Inside #2/2024
(2024)
BAM Update #1/2024
(2024)
Two-dimensional covalent organic frameworks (COFs) based on phosphinine and thiophene building blocks have been synthesized with two different side groups. The materials are denoted as CPSF-MeO and CPSF-EtO where CxxF correspond to the covalent framework, whereas P and S are related to heteroatoms phosphorous and sulfur. MeO and EtO indicate the substituents, i.e. methoxy and ethoxy.
Their morphologies were studied by scanning electron microcopy and X-ray scattering. The absence of crystalline reflexes in the X-ray pattern reveal that both materials are amorphous and can be considered as glasses. Furthermore, N2 adsorption measurements indicate substantial Brunauer–Emmett–Teller (BET) surface area values pointing to the formation of three-dimensional pores by stacking of the aromatic 2D layer. An analysis of the porosity of both COFs showed a mean radius of the pores to be of ca. 4 nm, consistent with their chemical structure. The COFs form nanoparticles with a radius of around 100 nm. The thermal behavior of the COFs was further investigated by fast scanning calorimetry. These investigations showed that both COFs undergo a glass transition. The glass transition temperature of CPSF-EtO is found to be ca. 100 K higher than that for CPSF-MeO. This large difference in the glass transition is discussed to be due to a change in the interaction of the COF sheets induced by the longer ethoxy group. It might be assumed that for CPSF-EtO more individual COF sheets assemble to larger stacks than for CPSF-MeO. This agrees with the much larger surface area value found for CPSF-EtO compared to CPSF-MeO. To corroborate the results obtained be fast scanning calorimetry dielectric measurements were conducted which confirm the occurrence of a dynamic glass transition. The estimated temperature dependence of the relaxation rates of the dielectric relaxation and their absolute values agrees well with the data obtained by fast scanning calorimetry. Considering the fragility approach to the glass transition, it was further found that CPSF-MeO is a fragile glass former whereas CPSF-EtO behaves as a strong glass forming material. This difference in the fragility points also to distinct differences in the interaction between the 2D COF molecules in both materials.
Evaluation of Heat Fluxes in Fire Reference Test Conducted in BAM Propane Gas Fire Test Facility
(2024)
Packages for the transport of intermediate- and high-level radioactive waste are designed to withstand severe accidents. The International Atomic Energy Agency (IAEA) has established specific mechanical and thermal tests. Packages for the transport of radioactive material must withstand these tests to comply with the Regulations for the Safe Transport of Radioactive Materials IAEA [IAEA (2018)]. A fire reference package was developed with the primary objective to demonstrate that the fire meets the regulatory requirements. Another aim is to characterise the boundary conditions of the actual fire as input parameters for thermo-mechanical simulations. A simple method to characterise the boundary conditions of a real steady state fire with a fire reference package is presented. The thermal test mainly consists of a 30 minute fully engulfing 800°C pool fire or an equally severe fire, such as a propane gas fire. The fire reference tests are performed prior to the actual fire test with the real package. The heat fluxes into the package depend substantially on the fire characteristics and the surface temperature of the package. To investigate local and overall heat fluxes over a wide range of surface temperatures in this test facility a fire reference package was designed for repeated use. The fire reference package presented in this paper represents the outer geometry of a small transport container for radioactive material and is used as a device in civil engineering. It is designed as a closed steel sheet cylinder with a wall thickness of 10 mm, a length of 182 mm and a diameter of 102 mm. The package was instrumented with thermocouples and filled with heat resistant insulation material. Open-air fire tests were performed in a BAM propane gas fire test facility with the fire reference package. The measured temperatures are used to determine the changes of heat fluxes into the fire reference package in relation to the package surface temperature. The calculated heat fluxes allow its fitting to express the thermal exposure as simple mathematical boundary condition. Therefore, in a first approach, fire properties such as adiabatic surface temperature (AST) as proposed by Wickström et al. (2007), convection coefficient and emissivity are determined mathematically fitting the heat flux development presented in this paper. The evaluated results provide an initial picture of local fire characteristics of the conducted propane gas fire and are a further development of previous works from Feldkamp et al. (2020). The results can be used in thermal and thermo-mechanical models to simulate the load on the real transport package in fire. The test shows that the examined propane gas fire covers the IAEA-fire over a wide range of surface temperatures with the chosen test stand parameters.