This study deals with the development of PEEK (polyehteretherketone) and PTFE (polytetrafluoroethylene) based composites, optimized for low friction and low wear performance under extreme environments. It is demonstrated that the incorporation of a harder polymer component into PTFE (such as PEEK particles), a short fiber reinforcement (e.g. carbon fibers CF), and internal lubricants (e.g. PTFE particles), helps to reduce the friction and to improve the wear resistance over a very wide temperature range.
The pyrolysis of an epoxy resin and the fire behavior of corresponding carbon fiber-reinforced composites, both flame-retarded with either 10-ethyl-9,10-dihydro-9-oxa-10-phosphaphenanthrene 10-oxide or 1,3,5-tris[2-(9,10-dihydro-9-oxa-10-phosphaphenanthrene 10-oxide-10-)ethyl]1, 3,5-triazine-2,4,6(1H,3H,5H)-trione, are investigated. The different fire retardancy mechanisms are discussed, and their influence on the fire properties assessed, in particular for flammability (limiting oxygen index, UL 94) and developing fires (cone calorimeter with different external heat fluxes of 35, 50, and 70 kW m-2). Adding the flame retardants containing 9,10-dihydro-9-oxa-10-phosphaphenanthrene-10-oxide affects the fire behavior by both condensed phase and gas phase mechanisms. Interactions between the additives and the epoxy resin result in a change in the decomposition pathways and an increased char formation. The release of phosphorous products results in significant flame inhibition. The fire properties achieved are thus interesting with respect to industrial exploration.
A systematic and comparative evaluation of the pyrolysis of halogen-free flame-retarded epoxy resins containing phosphine oxide, phosphinate, phosphonate, and phosphate (phosphorus contents around 2.6 wt.%) and the fire behaviour of their carbon fibre composites is presented. Decomposition pathways are proposed based on the thermal analysis (TG), TG coupled with evolved gas analysis (TG-FTIR), kinetics and analysis of the residue with FTIR and XPS. All organophosphorus-modified hardeners containing phenoxy groups lead to a reduced decomposition temperature and mass loss step for the main decomposition of the cured epoxy resin. With increasing oxidation state of the phosphorus the thermally stable residue increases, whereas the release of phosphorus-containing volatiles decreases. The flammability of the composites was investigated with LOI and UL 94 and the fire behaviour for forced-flaming conditions with cone calorimeter tests performed using different irradiations. The flame retardancy mechanisms are discussed. With increasing oxidation state of the phosphorus additional charring is observed, whereas the flame inhibition, which plays the more important role for the performance of the composites, decreases. The processing and the mechanical performance (delamination resistance, flexural properties and interlaminar bonding strength) of the fibre-reinforced composites containing phosphorus were maintained at a high level and, in some cases, even improved. The potential for optimising flame retardancy while maintaining mechanical properties is highlighted in this study.
Two different radical polymerization techniques have been applied to covalently graft vinylformamide (VFA) onto silica particles. Grafting by the polymerization of VFA using an immobilized azo initiator on silica has been found less effective, because monomer conversion is limited in non-aqueous solvents and grafting yields are low in water. Radical copolymerization of VFA with vinyltriethoxysilane (VTS)-functionalized silica particles is suitable to produce poly(vinylformamide) (PVFA) silica hybrid particles in respectable yield. The VFA/VTS-silica ratio determines the degree of grafting. The PVFA-VTS-co-grafted silica particles can be acidically hydrolyzed into poly(vinylamine)-grafted silica particles. Molecular structures of the surface groups and grafted polymer chains have been confirmed by means of solid state 13C{1H} cross-polarization magic-angle spinning (CP MAS) NMR spectroscopy. Zeta potential measurements show the altering of the former silica particles surface charges arising from the introduction of basic groups on the surface.
The search for durable and sustainable construction materials inspires the developments in the world of cement concrete, as well as in the world of concretepolymer composites. Both worlds recognize, strive for and accept each others contribution to the synergetic effects that are realized by the combination of classical building materials and polymers. A better knowledge of materials behaviour, especially in the field of admixtures, and a better understanding of curing processes allowed the development of highly performing mineral or modified mineral concretes, mortars and grouts. CPC-science becomes an invaluable element in the development of sustainable construction materials. ICPIC brings together practitioners and scientists, dealing with concretepolymer composites in all industrial fields, but with emphasis on construction industry. The 11th International ICPIC Congress took place in Berlin, 24th June 2004. New trends and evolutions have been presented and discussed. The highlights of the Congress, and the synergies for the construction world that emerge from this congress on polymers in concrete in combination with cement concrete, are presented.
After a delamination process in a C-fiber reinforced polymer composite, the identification of the polymer residue of poly-(phenylene sulphide) on carbon fiber surfaces gives important information on the composite failure mechanism. Using scanning force microscopy (SFM) in its lateral force imaging mode or with the stiffness imaging mode, it is almost impossible to distinguish the two composite components owing to a very low material-based contrast of the local friction and compliance. The new technique using contrast based on a local AC current measurement allows a clear identification of the conducting carbon fiber and the non-conducting polymer coverage.