The minimum information requirements needed to guarantee high-quality surface Analysis data of nanomaterials are described with the aim to provide reliable and traceable Information about size, shape, elemental composition and surface chemistry for risk assessment approaches.
The widespread surface analysis methods electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS) and secondary ion mass spectrometry (SIMS) were considered. The complete analysis sequence from sample preparation, over measurements, to data analysis and data format for reporting and archiving is outlined. All selected methods are used in surface analysis since many years so that many aspects of the analysis (including (meta)data formats) are already standardized. As a practical analysis use case, two coated TiO2 reference nanoparticulate samples, which are available on the Joint Research Centre (JRC) repository, were selected. The added value of the complementary analysis is highlighted based on the minimum information requirements, which are well-defined for the analysis methods selected. The present paper is supposed to serve primarily as a source of understanding of the high standardization level already available for the high-quality data in surface analysis of nanomaterials as reliable input for the nanosafety community.
Depth profiling of electrically non-conductive layered samples by RF-GDOES and HFM plasma SNMS
(2001)
The work is intended to compare the capabilities of two similar depth profiling techniques to analyse electrically non-conductive samples. In order to get a better evaluation of the depth resolution, various multilayer sandwiches, such as SiO2/TiO2 and Si3N4/SiO2 deposited on glass substrates have been investigated. Optimised depth profiles are presented for both methods, glow discharge optical emission spectrometry (GDOES) and radiofrequency mode (known as HFM in the SNMS literature) of plasma secondary neutral mass spectrometry (SNMS). The optimisation procedure, necessary to get the best set of plasma parameters, which result in the optimal depth resolution, is also described for one selected sample. Additionally, sputtering crater profilometry was carried out in order to check out the flatness of the sputtered crater. The influence of the thickness of the sample substrate on the sputtering rate is discussed. Finally, advantages and disadvantages of the use of these two depth profiling methods, especially for the non-conductive samples, are concluded from this comparative study. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) analysis of a cross-sectioned sample was carried out in order to get supplementary information.