Graphene is a two-dimensional carbon network with unique properties, including high mechanical stiffness, strength, and elasticity, outstanding electrical and thermal conductivity, and many others. Despite these advantages, its low solubility, poor reactivity and the limited accessibility of a well-defined basal plane are major challenges for applications. An ideal method to overcome these problems is the covalent attachment of functional molecules to its surface which enables further reactive modifications for specific applications. There is a number of different technologies for surface functionalization of graphene and related CNT materials. However, to get control on the functionalization process and to optimize the performance of the modified surfaces analytical tools for surface chemical characterization are required. X-ray absorption (NEXAFS) and photoelectron spectroscopy (XPS) have been identified to be rather powerful here. Specifically NEXAFS spectroscopy underpinned by quantum chemical spectrum simulations is unique in a way to address changes of aromaticity and defect formation at the graphene surface during functionalization.
For relevant surface modification technologies, we present examples on how NEXAFS and XPS can perform well. All presented modifications aim on the production of platforms for defined functional 2D nanomaterials, as for example multifunctional hybrid architectures. In detail, we investigated:
• Graphene and carbon nanotube functionalized by a Vacuum-Ultraviolet (VUV) induced photochemical process in NH3 or O2 atmospheres in order to introduce amino or hydroxy functionalities, respectively.
• Br bonding on r.f. cw low pressure plasma brominated graphite surfaces by using Br2 and bromoform as plasma gases.
• A wet chemical method for covalent functionalization of graphene sheets by a one-pot nitrene [2+1] cycloaddition reaction under mild conditions. Here a reaction between 2,4,6-trichloro-1,3,5-triazine and sodium azide with thermally reduced graphene oxide (TRGO) results in defined dichlorotriazine-functionalized graphene sheets.
CCQM has established a framework of comparisons to demonstrate the international comparability of chemical measurements. The key point is the establishment of comparable measurements, with traceability to internationally or nationally stated references.
Originally initiated by Dr Martin P Seah, NPL, the Surface Analysis Working Group (SAWG) has been formally founded in 2003. The following terms of reference were presented to CCQM in April 2002. CCQM ratified the group as a full working group of CCQM in April 2003 with these terms of reference:
- to develop pilot studies and carry out key comparisons of national measurement standards for surface and micro/nano-analysis;
- to assist in identifying and establishing inter-laboratory work to improve the traceability of surface and micro/nano-analysis;
- to establish and update a work plan to be adopted by CCQM;
- to discuss and review the scope of the working group and to liase with other working groups related to nanotechnology.
Following the 2016 meeting, the Key Comparison K-129 "Measurement of atomic fractions in Cu(In,Ga)Se2 Films" lead by KRISS and the Key Comparison K-136 on "BET specific surface area of nanoporous Al2O3" lead by UNIIM&BAM have been finished in 2016.
The 15th meeting of SAWG will focus on
- survey on CMC claim submitted with reference to K-129 and K-136.
- the overall and SAWG specific aspects of the CCQM Strategy process,
- a joint meeting with the Inorganic Working Group addressing number concentrations of nano particles,
- discussion of future comparisons.
The use of duplex stainless steels (DSS) in energy related applications is well known. Nowadays, DSS steels become more favorable than austenitic steels due to the outstanding mechanical properties, the good corrosion resistance and the lower nickel content. However, the use of the duplex grade in acidic environments such as seawater often leads to severe degradation of the structural integrity of the steel by hydrogen-induced/assisted cracking (HAC) phenomena, which can eventually result in premature failure. Hydrogen assisted degradation and cracking of steels are active fields of research even though this topic is intensively studied for more than a century. A bottleneck is the analytical validation of the theoretical models proposed ion the literature at the sub-micron scale.
Industrial and the research communities see a need for an accurate analytical method by which it is possible to image the distribution of hydrogen in the microstructure of a steels or and other alloys. Among the very few available methods hydrogen imaging methods, Time-of-Flight secondary ion mass spectrometry (ToF-SIMS) has the principal capability for mapping of hydrogen in a steel’s microstructure. The combination of ToF-SIMS with multivariate data analysis (MVA), electron microscopy (SEM) and electron-backscattered diffraction (EBSD) is a powerful approach for providing chemical and structural information. The use of data fusion techniques has been shown recently to enhance the better understanding of the hydrogen induced degradation processes in in a DSS steel.