Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (56)
- Vortrag (12)
- Posterpräsentation (12)
- Buchkapitel (5)
- Beitrag zu einem Tagungsband (5)
- Beitrag zu einem Sammelband (4)
- Dissertation (4)
- Sonstiges (3)
- Forschungsbericht (2)
Sprache
- Englisch (91)
- Deutsch (11)
- Mehrsprachig (1)
Schlagworte
- Polymer (103) (entfernen)
Organisationseinheit der BAM
- 6 Materialchemie (14)
- 1 Analytische Chemie; Referenzmaterialien (12)
- 1.2 Biophotonik (8)
- 5 Werkstofftechnik (6)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (5)
- 6.6 Physik und chemische Analytik der Polymere (5)
- 5.3 Polymere Verbundwerkstoffe (4)
- 1.7 Organische Spuren- und Lebensmittelanalytik (3)
- 6.3 Strukturanalytik (3)
- 7 Bauwerkssicherheit (3)
Eingeladener Vortrag
- nein (12)
Heterogeneous sandwich immunoassays are widely used for biomarker detection in bioanalysis and medical diagnostics. The high analyte sensitivity of the current “gold standard” enzyme-linked immunosorbent assay (ELISA) originates from the signal-generating enzymatic amplification step, yielding a high number of optically detectable reporter molecules. For future point-of-care testing (POCT) and point-of-need applications, there is an increasing interest in more simple detection strategies that circumvent time-consuming and temperature-dependent enzymatic reactions. A common concept to aim for detection limits comparable to those of enzymatic amplification reactions is the usage of polymer nanoparticles (NP) stained with a large number of chromophores. We explored different simple NP-based signal amplification strategies for heterogeneous sandwich immunoassays
that rely on an extraction-triggered release step of different types of optically detectable reporters. Therefore, streptavidinfunctionalized polystyrene particles (PSP) are utilized as carriers for (i) the fluorescent dye coumarin 153 (C153) and (ii) hemin (hem) molecules catalyzing the luminol reaction enabling chemiluminescence (CL) detection. Additionally, (iii) NP labeling with hemin-based microperoxidase MP11 was assessed. For each amplification approach, the PSP was first systematically optimized regarding size, loading concentration, and surface chemistry. Then, for an immunoassay for the inflammation marker C- eactive protein (CRP), the analyte sensitivity achievable with optimized PSP
ystems was compared with the established ELISA concept for photometric and CL detection. Careful optimization led to a limit of detection (LOD) of 0.1 ng/mL for MP11-labeled PSP and CL detection, performing similarly well to a photometric ELISA (0.13 ng/mL), which demonstrates the huge potential of our novel assay concept.
In the focus of division Biophotonics are the design, preparation, analytical and spectroscopic characterization, and application of molecular and nanoscale
functional materials, particularly materials with a photoluminescence in the visible, near infrared (NIR) and short-wave infrared (SWIR). This includes optical reporters for bioimaging and sensing, security and authentication barcodes, and materials for solid state lighting, energy conversion, and photovoltaics. For the identification of optimum particle structures quantitative spectroscopic studies are performed under application-relevant conditions, focusing on the key performance parameter photoluminescence quantum yield. In addition, simple, cost-efficient, and standardizable strategies for quantifying functional groups on the surface of nano- and microparticles are developed, here with a focus on optical assays and electrochemical titration methods, cross-validated by more advanced methods such as quantitative NMR. In addition, reference materials and reference products are developed for optical methods, particularly luminescence techniques, and for analytical methods utilized for the characterization of nanomaterials.
Reference materials are essential to analyze the impact of micro- and nanoplastics. The particle size D50 has been chosen as property of interest. They can be produced top-down by milling. For size separation down to a particle size D50 of 50 µm sieving is suitable while smaller particle sizes can be obtained by filtration. After production it is important to control the stability because microplastic in the size range below 10 µm tend to agglomerate.
Micro-(nano-)encapsulation technology involves building of a barrier between the core and the environment and offers a number of benefits to preserve the functional and physicochemical properties of core material. Tremendous progress has been made in synthesizing well-defined capsules to achieve desired properties such as particle size, chemical composition, and controlled release of the payload.
Encapsulation of volatile organic compounds (VOCs) that could evaporate with a defined rate is of immense interest for application in emission reference materials (ERM). These are urgently needed for quality assurance and quality control purposes (QA/QC) required by test standards for the determination of chemical emissions of construction and other materials for interior use. As such ERMs are hardly available on the market, the EU-funded EMPIR project MetrIAQ [1] was started to fill this gap by developing a material with temporally constant emission of VOCs typically found in indoor air.
Different capsules in a size range between 5 and 50 μm were synthesized through an interfacial polyaddition/polycondensation reaction in direct (water-in-oil) system. As VOC several types of hydrophobic liquid materials were used. After synthesis, the morphology and physicochemical properties of capsules were characterized by electron microscopy, FTIR and DSC/TGA. An encapsulation efficiency up to 90% could be reached. The emission kinetic of volatile agents was studied in emission test chambers at 23 °C and 50% RH for 14 days. First results indicate that variation of the cross-linking grade of the shell material is one important parameter to adjust the desired emission rate. The overall aim is to achieve a consistent emission profile that decreases by less than 10 % over a target period of at least 14 days.
Micro- and nanoplastic particles became a topic of public concern all over the world e.g. in water, soil, sludge and air. For a profound risk assessment, it is necessary to identify the origins, hotspots, or transport between different media. Therefore, a representative repeatable analysis is required and reference materials (RM) to proof and compare methods.
The basis of MNP investigations is a harmonized analysis which includes sampling, sample preparation and detection. In recent years, spectroscopic methods like µRaman and µFTIR for the determination of particle numbers or thermoanalytical methods like Pyrolysis gas chromatography/mass spectrometry (py-GC/MS) and Thermo extraction/ desorption gas chromatography / mass spectrometry (TED-GC/MS) for mass determination have proven to be particularly suitable.
The technical committees (TC) of ISO TC 61 “plastics” and TC 147 “water quality" are working on harmonisation processes on international level. For all standardization approaches, it is necessary that the detection methods and analysis processes can be validated. Therefore, BAM develops reference material for microplastic (MP) analysis for several years with focus on the most common polymers PE, PP, PS, PET and PA.
MP particles with a close to reality fragment shape are obtained by cryomilling and sieving. For sample preparation purposes with mass detection methods MP particles are pressed into pills with a water-soluble matrix. Thereby losses due to sample preparation e.g. filtration are included in the verification of an analysis.
To ensure a constant quality throughout all MP RM batches the homogeneity and stability is controlled according to ISO Guide 35. Next to TED-GC/MS measurements particle size distribution, infrared spectroscopy and differential scanning calorimetry spectra are taken as accompanying parameters.
This presentation aims to introduce into the MP RM production process with ensured quality and special focus on pointing out customized setups for particle comminution, separation, and characterization for standardization.
Post-assembly modifications are efficient tools to adjust colloidal features of block copolymer (BCP) particles. However, existing methods often address particle shape, morphology, and chemical functionality individually. For simultaneous control, we transferred the concept of seeded polymerization to phase separated BCP particles. Key to our approach is the regioselective polymerization of (functional) monomers inside specific BCP domains. This was demonstrated in striped PS-b-P2VP ellipsoids. Here, polymerization of styrene preferably occurs in PS domains and increases PS lamellar thickness up to 5-fold. The resulting asymmetric lamellar morphology also changes the particle shape, i.e., increases the aspect ratio. Using 4-vinylbenzyl azide as co-monomer, azides as chemical functionalities can be added selectively to the PS domains. Overall, our simple and versatile method gives access to various multifunctional BCP colloids from a single batch of pre-formed particles.
Flexible, niedrigdichte Schäume aus Biokunststoffen im Extrusionsverfahren herzustellen war bisher industriell noch nicht möglich. Im Verarbeitungstechnikum Biopolymere des Fraunhofer IAP wurde in einem Projekt die Eignung von PBS-basierten Biokunststofftypen für Schaumanwendungen erforscht und weiterentwickelt.
A first tricolor fluorescent pH nanosensor is presented, which was rationally designed from biocompatible carboxylated polystyrene nanoparticles and two analyte-responsive molecular fluorophores. Its fabrication involved particle staining with a blue-red-emissive dyad, consisting of a rhodamine moiety responsive to acidic pH values and a pH-inert quinoline fluorophore, followed by the covalent attachment of a fluorescein dye to the particle surface that signals neutral and basic pH values with a green fluorescence. These sensor particles change their fluorescence from blue to red and green, depending on the pH and excitation wavelength, and enable ratiometric pH measurements in the pH range of 3.0−9.0. The localization of the different sensor dyes in the particle core and at the particle surface was confirmed with fluorescence microscopy utilizing analogously prepared polystyrene microparticles. To show the application potential of these polystyrene-based multicolor sensor particles, fluorescence microscopy studies with a human A549 cell line were performed, which revealed the cellular uptake of the pH nanosensor and the differently colored emissions in different cell organelles, that is, compartments of the endosomal-lysosomal pathway. Our results demonstrate the underexplored potential of biocompatible polystyrene particles for multicolor and multianalyte sensing and bioimaging utilizing hydrophobic and/or hydrophilic stimuli-responsive luminophores.
Biofilms are ubiquitous in nature and in the man-made environment. Given their harmful effects on human health, an in-depth understanding of biofilms and the monitoring of their formation and growth are important. Particularly relevant for many metabolic processes and survival strategies of biofilms is their extracellular pH. However, most conventional techniques are not suited for minimally invasive pH measurements of living biofilms. Here, a fluorescent nanosensor is presented for ratiometric measurements of pH in biofilms in the range of pH 4.5–9.5 using confocal laser scanning microscopy. The nanosensor consists of biocompatible polystyrene nanoparticles loaded with pH-inert dye Nile Red and is surface functionalized with a pH-responsive fluorescein dye. Its performance was validated by fluorometrically monitoring the time-dependent changes in pH in E. coli biofilms after glucose inoculation at 37 °C and 4 °C. This revealed a temperature-dependent decrease in pH over a 4-h period caused by the acidifying glucose metabolism of E. coli. These studies demonstrate the applicability of this nanosensor to characterize the chemical microenvironment in biofilms with fluorescence methods.