Filtern
Erscheinungsjahr
- 2023 (839) (entfernen)
Dokumenttyp
- Vortrag (839) (entfernen)
Sprache
- Englisch (609)
- Deutsch (228)
- Französisch (1)
- Mehrsprachig (1)
Referierte Publikation
- nein (839)
Schlagworte
- Hydrogen (29)
- Korrosion (25)
- Additive manufacturing (22)
- Wasserstoff (20)
- Additive Fertigung (17)
- Corrosion (17)
- Residual stress (17)
- Additive Manufacturing (16)
- H2Safety@BAM (16)
- Safety (16)
Organisationseinheit der BAM
- 6 Materialchemie (151)
- 9 Komponentensicherheit (147)
- 7 Bauwerkssicherheit (130)
- 8 Zerstörungsfreie Prüfung (126)
- 9.4 Integrität von Schweißverbindungen (88)
- 1 Analytische Chemie; Referenzmaterialien (85)
- 5 Werkstofftechnik (73)
- 4 Material und Umwelt (69)
- 3 Gefahrgutumschließungen; Energiespeicher (62)
- 2 Prozess- und Anlagensicherheit (53)
Influence of Residual Stresses on Stress Relief Cracking of Thick-Walled Creep-Resistant Steel Welds
(2023)
Controlling the residual stress level during welding of creep-resistant Cr-Mo-V steels is crucial to avoid so called stress relief cracking (SRC) during post weld heat treatment (PWHT) of large-scale components. In the present study, a laboratory scale test specimen (400 mm x 400 mm x 25 mm) was used to simulate thick-walled component welds made of 13CrMoV9-10. The aim was to identify the level and distribution of residual stresses to evaluate the suitability of the specimen for laboratory based SRC testing. High restraint was ensured by the specimen geometry with a narrow welding gap in the center. This gap was filled by submerged arc welding in a multi-layer technique. Two specimens were welded with identical parameters and compared in the as-welded state and after PWHT (705 °C for 10 h). Neutron diffraction was used to determine the residual stresses in the weld metal, the heat-affected zone (HAZ) and the base material at different depths longitudinal, transverse, and normal to the welding direction. The experiments were performed on the instrument E3 of the research reactor BERII of HZB Berlin, Germany. Complementarily, laboratory X-ray diffraction was applied to characterize the surface residual stresses. In the welded state, especially in the weld metal and the adjacent HAZ, the residual stress can reach the yield strength of the untreated material. The highest levels occur in the longitudinal direction. The transverse and normal directions are characterized by residual stress of lower magnitude. As expected, the residual stress is almost completely relieved after PWHT.
Bei dem Vortrag werden die potentiellen mikrobiologischen Einflüsse im Falle der Lagerung von Wasserstofflagerung in unterirdischen geologischen Formationen vorgestellt, die Zusammenarbeit mit internen und auch externen Partnern. Der Fokus liegt dabei auf UGF; anaerobe Umgebungen, Sulfate reduzierenden Bakterien, methanogenen Archaea, weiterleitenden Systeme und die Kombination der Untersuchung abiotisch/biotische
In our (dramatically understaffed) X-ray scattering laboratory, developing a systematic, holistic methodology1 let us provide scattering and diffraction information for more than 2100 samples for 200+ projects led by 120+ collaborators over the last five years. Combined with universal, automat-ed data correction pipelines, as well as our analysis and simulation software, this led to more than 40 papers2 in the last 5 years with just over 2 full-time staff members.
While this approach greatly improved the consistency of the results, the consistency of the samples and sample series provided by the users was less reliable nor necessarily reproducible. To address this issue, we built an EPICS-controlled, modular synthesis platform to add to our laboratory. To date, this has prepared over 1200 additional (Metal-Organic Framework) samples for us to meas-ure, analyse and catalogue. By virtue of the automation, the synthesis of these samples is automat-ically documented in excruciating detail, preparing them for upload and exploitation in large-scale materials databases alongside the morphological results obtained from the automated X-ray scat-tering analysis.
Having developed these proof-of-concepts, we find that the consistency of results are greatly im-proved by virtue of their reproducibility, hopefully adding to the reliability of the scientific findings as well. Additionally, the nature of the experiments has changed greatly, with much more emphasis on preparation and careful planning. This talk will discuss the advantages and disadvantages of this highly integrated approach and will touch upon upcoming developments.
The performance of titanium alloy (Ti6Al4V) surfaces was investigated in lubricated reciprocating sliding tribological tests (RSTT). Special emphasis was laid on the effect of surface nanostructures in area of contact on the respective friction and wear behaviour. These so-called laser-induced periodic surface structures (LIPSS, ripples) were produced on the titanium alloy surface upon scan processing in air by an ultrashort pulsed femtosecond (fs) laser. As lubricant served two types of base oils, a pure polyalcylene-glycol, and an SAE 0W30 oil containing only antioxidants and temperature stabilizers. Tribological tests were carried out on polished as well as LIPSS covered areas using both types of base oil. A test metrics was established, combining the additive 2-ethylhexyl-zincdithiophosphate (ZDDP) or the ionic liquid [P6,6,6,14] [DEHP] (98% purity) with the respective base oils. The test metrics also considered the orientation of motion with respect to the orientation of the structures formed on the surface. Results are presented which show that the interplay between LIPSS and the local chemistry formed by the respective additives is beneficial for the tribological behaviour of the titanium alloy. Certain combinations of base oil, additive and LIPSS reduced friction and wear significantly in the tribological contact.
In the field of explosive reactions, there is a type of explosive effect that lacks a sufficient database and reproducible experiments regarding biomechanics. It concerns the primary explosive effect. It is defined as pure shock wave of the explosion. The physical behavior of the shock wave when interacting with different types of tissue and, in particular, the subsequent transitions of the shock wave, have barely been investigated. The transition of the shock wave into other materials is the focus of the research Therefore, the aim of the investigations is the development of a multidisciplinary method to investigate shock wave behavior in various generic tissue simulants under the most reproducible conditions possible with realistic loads in an experimental test series with short set-up times. An autoclave is used to generate the pressure waves. A simplified torso model consisting of ballistic gelatin is used as a simulant. In this paper, the influence of protective equipment on the pressure load in the tissue simulant is investigated. For this purpose, consecutive test setups are used. First, the behavior of ballistic gelatin as a tissue simulant is investigated. Then, the simplified torso model is covered with typical combat clothing consisting of four layers. Afterwards a currently used UHMWPE ballistic protective plate is placed in front of the simplified torso model. Finally, the combat clothing and the protective plate are examined in combination. Three cast-in pressure sensors are used as measuring devices, as well as an acceleration sensor attached to the protective plate. The experiments show that the maximum overpressure in a model protected by combat clothing and the protective plate can be reduced by 95%. However, the propagation speed of the shock wave within the simplified torso model increases from 1535.5 m/s to 2204.5 m/s. This shows that even protective equipment, which is not primarily intended to protect against blast, offers a significant reduction in the pressure load in the protected area. On the one hand it is caused by the media transition from air to PE and the resulting higher reflection of the acceleration of the transmitted wave within the simulant. On the other hand, it is also reduced due to the damping and dispersion caused by the clothing layers.
For intumescent coatings durability is an important aspect. Due to ageing, which is caused by climatic conditions, the thermal protection performance of intumescent coatings can be reduced during the working life. The national German and the European procedures to assess the durability of intumescent coatings presume a working life of 10 years. For a longer period, additional investigations are required. However, the European assessment procedure does not provide specific information how to prove a durability of more than 10 years. In addition to this formal reason, also from a scientifical position, it is necessary to investigate the degradation of intumescent coatings in detail to propose a corresponding test concept for a durability of more than 10 years.
The presentation summarises the existing knowledge about the degradation behaviour and ageing of intumescent coatings. Furthermore, the results of different approaches from a recently conducted research project are presented. Starting from a water-based and an epoxy-based guide formulation, in a first approach a degradation of the intumescent coating was carried out directly during the production process, i.e. by reducing the concentration of functionally relevant chemical components. In another approach, the duration of the short-term weathering tests was significantly extended, i.e. by multiple repetition of the artificial weathering. The thermal protection performance of the intumescent coating was assessed by fire tests and tests with electrical heating source. In addition, small-scale tests were carried out to determine the thermal material properties of the intumescent coating and thermo-analytical methods were applied to characterise the degradation. Derived from this knowledge, possibilities to test and assess a working life for a period of more than 10 years are proposed.
Was Sie schon immer über Chunky-Graphit wissen w(s)ollten, aber bisher nicht zu fragen wagten
(2023)
Duktile Gusseisenwerkstoffe mit Kugelgraphit (GJS) haben ein erhebliches technisches Potenzial und sind von wirtschaftlicher Bedeutung. Nicht zuletzt daher ist es ökonomisch sinnvoll, gesellschaftlich nachhaltig und wissenschaftlich interessant, ihren Herstellungsprozess zu optimieren. Eine maßgebliche Rolle kommt hierbei der Vermeidung von Qualitätsabweichungen in Form von Gefügefehlern zu. Dieser Beitrag befasst sich mit der – leider vielfach nicht richtig oder zu wenig verstandenen, aber insbesondere bei kostenintensi-ven dickwandigen Gussteilen relevanten - Graphitentartung Chunky-Graphit (CG).
Die metallurgischen Ursachen von CG werden noch immer kontrovers diskutiert. Eine allgemein akzeptierte Theorie zur Bildung und dem Wachstumsmechanismus von CG existiert nicht, in der Gießereipraxis wird gleichwohl eine Fülle spezifischer technologischer Abhilfemaßnahmen praktiziert [1].
Der Schwerpunkt dieses Beitrages liegt jedoch nicht auf der metallurgischen Seite, sondern auf der Beschrei-bung der spezifischen Morphologie von CG (Bild 1), dessen Detektion im Werkstoff bzw. Bauteil sowie den Auswirkungen von CG auf die Werkstoffeigenschaften. Detailliert werden Möglichkeiten und Grenzen zer-störungsfreier und zerstörender Untersuchungsverfahren zur Identifikation und Quantifizierung von CG aufgezeigt. Ausgehend von der charakteristischen Morphologie von CG wird dessen Einfluss auf das Ver-formungs- und Bruchverhalten von GJS behandelt. Beispielhaft werden dabei die Eigenschaften Festigkeit, Verformbarkeit, das Risswachstumsverhalten und die Bruchzähigkeit diskutiert und Schlussfolgerungen für die Bewertung von mit CG behafteten GJS-Bauteilen abgeleitet.
Kunststoffdichtungsbahnen (KDB) aus PE-HD (Polyethylen hoher Dichte) werden häufig zur Abdichtung von Bauwerken in der Geotechnik verwendet. Diese Produkte werden aus einem Kunststoff mit relativ komplexer Zusammensetzung hergestellt. Um eine Aussage über die Haltbarkeit von KDB aus PE-HD treffen zu können, muss das Materialverhalten berücksichtigt werden. In diesem Zusammenhang sind die wichtigsten Aspekte der Dauerhaftigkeit die Spannungsrissbeständigkeit und die Beständigkeit gegen Oxidation. Verschiedene PE-Sorten weisen eine unterschiedliche Spannungsrissbeständigkeit auf. Um dieser Eigenschaft von PE-HD zu begegnen, werden nur KDB aus sehr hochwertigen Rohstoffen zugelassen. Auf der anderen Seite werden hohe Anforderungen an die umgebenden Schichten, wie Auflager und Schutzschicht gestellt, um möglichst geringe Spannungen zu erzeugen und damit Dehnungen die Dehnungen der KDB gering zu halten. Bestimmte Medien, die bei den betreffenden Prüfungen verwendet werden, dürfen nicht mehr in der EU in Verkehr gebracht werden. Im Folgenden sollen die Zusammenhänge in Kürze dargestellt werden.
Darüber hinaus sollen Diskussionen und Änderungen im Zusammenhang mit der Zulassungsrichtlinie für KDB vorgestellt werden. Der aktuelle Stand der Diskussion im Zusammenhang mit den verwendeten Tensiden in Bezug auf die Spannungsrissprüfung und weiterer Prüfungen wird aufgezeigt. Änderungen der Fremdprüfung von sogenannten Sandschutzmatten, des Standards zur Qualitätsüberwachung (SQÜ) von Kunststoff Dränelementen (KDE) und der Anpassung der Formulierungen zum Überbau der in Abdichtungen verwendeten Produkte werden in Kürze aufgezeigt.
A significant number of new wind farms has to be installed and, at the same time, existing wind farms reaching the end of their planned life need to be reused efficiently to ensure that the ambitous goals for deploying offshore wind are met. Some relevant reuse alternatives for offshore wind farms are lifetime extension, repowering utilizing existing substructures and full replacement. In this presentation - starting from experience gained from extending the lifetime of the of the U1 metro viaduct in Berlin - we discuss end-of-life decision making in offshore wind. We focus particularly on issues concerning substructures and highlight existing challenges and opprtunities in research and development.
Als Beispiel für moderne Produktion ist die additive Fertigung (ugs. „3D-Druck“) bei der Herstellung von hochkomplexen metallischen Bauteilen, bionisch inspiriertem Leichtbau oder Prototypen nicht mehr wegzudenken. Die Qualitätssicherung (QS) von Bauteilen für sicherheitskritische Anwendungen stellt jedoch noch eine Herausforderung dar. Die Additive Fertigung (AM) ist ein vergleichsweise junges und datenintensives Fertigungsverfahren. Daher ist es ideal geeignet, die neuen Werkzeuge einer digitalen Qualitätsinfrastruktur (QI) für die moderne Produktion zu erproben und weiterzuentwickeln.