Filtern
Erscheinungsjahr
- 2018 (21) (entfernen)
Dokumenttyp
- Vortrag (12)
- Beitrag zu einem Tagungsband (4)
- Zeitschriftenartikel (3)
- Handbuch (1)
- Sonstiges (1)
Schlagworte
- Korrosion (18)
- Potentialfeldmessung (12)
- Corrosion (10)
- Betonstahl (4)
- Verzinkt (3)
- Monitoring (2)
- Potential mapping (2)
- Alkali-activated materials (1)
- Beton (1)
- Carbonation (1)
Organisationseinheit der BAM
- 7.6 Korrosion und Korrosionsschutz (21) (entfernen)
Eingeladener Vortrag
- nein (12)
Alkali-activated fly ash mortars were studied with regard to durability-relevant transport coefficients and the electrochemical behaviour of embedded carbon steel bars on exposure of the mortars to leaching, carbonation and chloride penetration environments. The transport coefficients differed considerably between different formulations, being lowest for a mortar with BFS addition, but still acceptable for one of the purely fly ash-based mortars. Leaching over a period of ~300 days in de-ionized water did not lead to observable corrosion of the embedded steel, as shown by the electrochemical data and visual inspection of the steel. Exposure to 100 % CO2 atmosphere caused steel depassivation within approx. two weeks; in addition, indications of a deterioration of the mortar were observed. The results are discussed in the context of the different reaction products expected in high- and low-Ca alkali-activated binders, and the alterations caused by leaching and carbonation.
Electrochemical potential mapping according to guideline B3 of DGZfP (German Society for Nondestructive Testing) is a recognized technique for the localization of corroding reinforcing steels. In reinforced concrete structures the measured potentials are not necessarily directly linked to the corrosion likelihood of the reinforcing steel. The measured values may be significantly affected, different from, e.g., stress measurement, by different influences on the potential formation at the phase boundary metal/concrete itself as well as the acquisition procedure. Due to the complexity of influencing factors there is a risk that the results are misinterpreted. Therefore, in a training concept firstly the theoretical basics of the test method should be imparted. Then, frequently occurring practical situations of various influencing factors will be made accessible to the participants by a model object specially designed for this purpose. The aim is to impart profound knowledge concerning the characteristics of potential mapping for detecting corrosion of reinforcing steel in order to apply this technique in practice as reliable and economical test method.
Potential to be used as binders for concrete with beneficial engineering properties and reduced manufacturing CO2 emissions. Knowledge of the durability of steel in these concretes and related properties of alkali-activated materials is a prerequisite for their application as building materials, if they are to be used for steel reinforced elements. However, to date only limited data exists on this topic. The present contribution focuses on durability-related transport properties of geopolymer-based mortars (as model systems for concrete). We report results of a polarization resistance data and corrosion potential vs. time curves for carbon steel bars embedded in a fly ash-based geopolymer mortar and a CEM I-based mortar (as reference) leached continuously over a period of 365 days.
Korrosionsmonitoring von Stahl- oder Spannbetonbauwerken hat in den vergangenen Jahren als Ergänzung zur herkömmlichen Bauwerksuntersuchung deutlich an Relevanz gewonnen. Einsatzgebiete sind z. B. Bauteile, die nach Fertigstellung nicht mehr zugänglich sind oder an denen aufgrund vorhandener Beschichtungen keine Potentialfeldmessungen durchgeführt werden können. Weiterhin kann Korrosionsmonitoring auch für die Überwachung des Korrosionsfortschritts an korrodierenden Systemen z. B. zum Nachweis des Instandsetzungserfolgs bei Anwendung des Prinzips W-Cl gemäß Instandsetzungsrichtlinie des DAfStb oder zum Funktionsnachweis bei KKS-Installationen nach DIN EN ISO 12696 eingesetzt werden. Trotz zunehmender Bedeutung Existieren für das Korrosionsmonitoring bis dato keine Richtlinien oder Handlungsempfehlungen. Diese Lücke soll das Merkblatt B12 „Korrosionsmonitoring von Stahl- und Spannbetonbauwerken“ der Deutschen Gesellschaft für
zerstörungsfreie Prüfung DGZfP füllen, das im Frühjahr 2018
veröffentlicht wurde. In diesem Beitrag werden das Merkblatt B12 vorgestellt, die grundlegenden Messprinzipien erläutert und anhand von Anwendungsbeispielen das Potenzial von Korrosionsmonitoring bei Neubau- und Bestandsobjekten illustriert.
Corrosion behavior of galvanized reinforcement in chloride containing mortar and carbonated mortar
(2018)
Korrosionseigenschaften von feuerverzinktem Betonstahl unterscheiden sich grundlegend von herkömmlichen Betonstahl. In diesem Vortrag sind Beispiele für das Korrosionsverhalten in chloridhaltigen und carbonatisierten Mörteln dargestellt