Filtern
Dokumenttyp
- Vortrag (831) (entfernen)
Sprache
- Englisch (446)
- Deutsch (381)
- Mehrsprachig (3)
- Tschechisch (1)
Referierte Publikation
- nein (831)
Schlagworte
- Korrosion (190)
- Corrosion (83)
- Nichtrostender Stahl (46)
- Potentialfeldmessung (40)
- Zink (29)
- KorroPad (26)
- Korrosionsprüfung (26)
- Korrosionsschutz (25)
- Deckschichtbildung (24)
- Gelartige Elektrolyte (21)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (831) (entfernen)
Since we are facing more extreme weathers, the occurrence
of wildfire has also increased accordingly. The EU project
TREEADS aims to adopt a holistic forest fire management
and an adaptive, collaborative governance approach based
on the deployment of a new systemic and technological
framework covering all three interconnected fire
management stages: prevention & preparedness, detection &
response, and restoration & adaptation.
As part of the task in the so-called German pilot, numerical
simulations are performed to investigate the influencing
factors for vegetation fires with fire dynamics simulator
(FDS). The characteristics of vegetation are strongly related
to the local weather and ecosystem. The investigation of the
fire behavior of vegetation must be based on the local
vegetation in Germany. Thus, the flame propagation of typical
vegetation in Germany (pine needles, oak leaves, European
beech leaves etc.) was investigated in small scale and medium
scale experiments. These results are used as validation case
studies for the further simulations.
Revolutionizing our polymer industry for adaption to a sustainable carbon circular economy has become one of today’s most demanding challenges. Exploiting renewable resources to replace fossil-fuel—based plastics with biopolymers such as poly(lactic acid) (PLA) is inevitable while using waste streams as a raw material resource at least is promising. When it comes to using PLA as technical polymer, its high flammability must be addressed by flame retardants compatible with the thermoplastic processing of PLA and its compostability. This study proposes microalgae enriched with phosphorus from wastewater (P-Algae) as an elegant way towards a kind of sustainable organophosphorus flame retardant. The concept is demonstrated by investigating the processing, pyrolysis, flammability, and fire behavior of PLA/P-Algae, while varying the P-Algae content and comparing P-Algae with four alternative bio-fillers (phosphorylated lignin, biochar, thermally treated sewage sludge, and metal phytate) with different P-contents as meaningful benchmarks.
Durch das alkalische Porenwassermilieu ist Stahl im Beton vor Korrosion geschützt. Unter ungünstigen Umgebungsbedingungen (Karbonatisierung, Chlorideintrag) kann die passive Deckschicht auf der Stahloberfläche zerstört werden. Im weiteren Verlauf können sich korrosionsbedingte Folgeschäden, wie Risse und Abplatzungen am Bauwerk ergeben. Um notwendige Sanierungsmaßnahmen sind frühzeitige und weitgehend zerstörungsfrei ermittelte Informationen über das aktuelle Korrosionsverhalten der Stahlbewehrung von großer Bedeutung. Die Potentialfeldmessung ist ein etabliertes und weit verbreitetes Verfahren zur Beurteilung des Korrosionszustandes der Bewehrung in Stahlbetonbauwerken. Mit Hilfe dieses Verfahrens können Bereiche aktiv korrodierender Bewehrung zerstörungsfrei lokalisiert werden. In der Regel kommt diese Messmethode bei der Detektion chloridinduzierter Korrosion zum Einsatz. Wie und unter welchen Randbedingungen dieses Messverfahren zielführend eingesetzt werden kann, ist im Merkblatt B 03 der dgzfp erörtert.
Electrochemical potential mapping is a recognized technique for the localization of corroding reinforcing steels. Areas of corroding reinforcement steel can be located in a non-destructive manner by means of this procedure. Half‐cell potential measurements are used in order to detect chloride‐induced corrosion. However, it is not recommended in order to assess the risk of carbonation‐induced corrosion. For this purpose, determining the carbonation depth and the concrete cover appears more appropriate. The content of this specification exclusively refers to the application of mobile, local variable reference electrodes, which are only placed on the concrete surface while measuring. The technique distinguishes itself thereby from the range of corrosion monitoring systems with stationary installed reference electrodes and sensor systems, respectively, whereby it is possible to continuously track measurements within the area of the installed electrodes. However, these methods are not dealt with in this specification.
DIN 4871
(2024)
Fire-induced spalling of normal strength concrete with different types of blended Portland cement
(2024)
The cement industry is looking to reduce its overall CO2 footprint. Greener manufacturing can be achieved by the introduction of more clinker-reduced cements. Concrete exposed to fire tends to show explosive spalling caused by thermomechanical and thermohydraulic processes. It is therefore essential to determine how concretes with clinker-reduced cements behave under fire exposure, especially for concretes containing calcined clays, as these are expected to be the supplementary cementitious material of the future. In this paper, normal strength concretes with four different cements (CEM I, CEM II/A-LL, CEM III/A and CEM II/B-Q) were examined for their fire-induced spalling behaviour. In addition, a mix with PP fibres was investigated for each concrete. The experiments were conducted on ring-restrained cylindrical specimens exposed to the hydrocarbon fire curve. The results showed that the cement type influences spalling behaviour. Samples with CEM I spalled the least, followed by CEM II/A-LL and CEM III/A. Finally, samples with CEM II/B-Q showed the most severe damage. It was found that the spalling behaviour of different concretes correlates with the moisture content before exposure to fire, meaning that higher moisture content leads to higher spalling susceptibility. The use of 2 kg/m³ PP fibres completely inhibited spalling regardless of the cement type used and therefore remains a successful avoidance strategy.
Wir stellen unseren Ansatz und unsere Methodik zur Simulation von Piping-Erosion vor, welche während des Installationsprozesses von Suction Bucket Fundamenten für Offshore-Windkraftanlagen auftreten kann und ein kritisches Versagen des Installationsprozesses darstellt. Wir zeigen die Ergebnisse mehrere Simulationen und analysieren die hydrodynamischen und Kontaktkräfte, die auf das granulare Medium wirken, sowie die Druckdifferenz der flüssigen Phase. Solche Simulationen können zum besseren Verständnis von Piping-Erosion und letztendlich zu dessen Verhinderung beitragen.