Quantitative laser-induced breakdown spectroscopy (LIBS) analysis operates on the assumption that the sample is completely dissociated and diffused within the highly energetic plasma on time-scales of analyte analysis, resulting in analyte emission ideally at the bulk plasma temperature and a signal that is linear with analyte mass concentration. However, recent studies focusing on aerosol analysis have found the heat and mass diffusion rates within laser-induced plasmas to be finite, resulting in particle-rich, locally perturbed areas within the hot bulk plasma. The goal of this study is to observe any related plasma differences, by calculating the bulk and local (i.e. analyte rich regions) plasma temperatures and electron density, to better understand the time frame of equilibrium between the local and bulk plasma properties. This study also seeks to determine whether the presence of large quantities of a matrix element can significantly alter the local plasma conditions, thereby generating matrix effects. We report the temporal profiles of particle-derived species, adding additional insight into the effect of local perturbation of plasma properties, with the conclusion that significant plasma residence (tens of microseconds) is necessary to minimize such effects.
Carbamazepine is a psychiatric pharmaceutical widely detected in aquatic environments. Due to its generalized occurrence and environmental persistence it might be considered as an anthropogenic pollution indicator. In this research, a previously developed enzyme-linked immunosorbent assay (ELISA), based on a commercial monoclonal antibody, was applied to the quantification of carbamazepine in ground, surface and wastewaters and results were validated by liquid chromatographytandem mass spectrometry (LCMS/MS).
The performance of the applied ELISA methodology was tested in the presence of high concentrations of sodium chloride and dissolved organic matter. The method was not significantly affected by matrix effects, being adequate for the quantification of carbamazepine in environmental samples, even without sample pre-treatment. This method allows the quantification of carbamazepine in the range of 0.0310 µg L-1, with a relative error lower than 30%. Due to a pH dependent cross-reactivity with cetirizine, an antihistaminic drug, the assay also enabled the quantification of cetirizine in the samples.
The application of the developed method to the quantification of carbamazepine was performed by using environmental samples with very different matrices, collected in the geographical area of Ria de Aveiro, an estuarine system located in the North of Portugal. Carbamazepine was detected in all analyzed wastewater samples and in one surface water with concentrations between 0.1 and 0.7 µg L-1. Validation with LCMS/MS revealed that results obtained by ELISA are 228% overestimated, which was considered highly satisfactory due to the absence of sample pre-treatments.
The implementation of the Water Framework Directive (2000/60/EC) requires the establishment of monitoring programs. However, conventional procedures for sample preparation prior to chromatographic analysis are rather expensive and time consuming, being the development of cost-effective and easy tool a necessity. The aim of this work was to develop an enzyme-linked immunosorbent assay (ELISA) able to determine atrazine in water samples. Matrix effects evaluation showed that the increase of humic acid (HA) concentration leads to flattened calibration curves and to the loss of the sigmoidal shape. However, such interference was overcome, by the presence of an environmental sample buffer, incubated together with the samples. Recoveries from 88.5 to 119.2 % were obtained in the presence of HA concentrations up to 20 mg-1. An analytical range from 0.003 to 1 µgL-1 was obtained, and atrazine was detected in a sewage treatment plant with concentrations ranging from 14 to 52 ngL-1.
Analyte atomization in an inductively coupled argon plasma is studied with spatial and temporal resolution by simultaneous side- and end-on emission spectroscopy. The samples are either introduced as single monodisperse microdroplets of analyte solution or in form of spherical nano- or microparticles with narrow size distributions embedded in microdroplets. While end-on spectroscopy provides quantitative information on the total atomization process during the transport through the ICP of a single injection event, side-on measurements deliver the spatial positions of the processes. It is shown that there are significant spatial shifts of the position of analyte atomization in dependence on injector gas flow, droplet size, analyte mass, and the mass of accompanying elements. These shifts have direct influence on the size of the analyte clouds at a particular position in the ICP, e.g., at the position of the sampler of a mass spectrometer in ICP-MS, and, therefore, on the detection efficiency of this technique. Furthermore, the dynamic processes of analyte ionization as well as element dependent diffusion were studied with spatial and temporal resolution.