Active thermography with lock-in excitation is a non-destructive testing method that is also feasible for testing of carbon fiber reinforced polymers (CFRP). For validating the method extensive investigations were done during a research project in order to advance a standardization process.
The most important parameters of optical and ultrasonic excitation thermography were investigated. For example, the appropriate selection of spectral sensitivity of the used infrared camera systems is important for recording undisturbed thermal signals. Regarding excitation,
influences of excitation power and ultrasonic frequency were studied. Furthermore, material parameters such as CFRP layup are known for strongly affecting the results of
measurement.
Mit Laserlicht kann man eine Materialoberfläche berührungslos und schnell moduliert aufheizen. Dabei entsteht eine stark gedämpfte Wärmewelle, die tief ins Material eindringen kann. Erzeugt und überlagert man solche thermischen Wellen auf kohärente Weise, dann kann man damit versteckte Materialfehler zerstörungsfrei und sehr präzise aufspüren. Sogar eine bildgebende Tomografie ist denkbar.