The most efficient construction materials for boiler water walls and superheaters in steam power plants are ferritic and martensitic steels. In practical operation, tubes are exposed simultaneously to combustion gas and air/steam on their opposite surfaces. The corrosion behavior of ferritic-martensitic steels under such dual atmospheres is nondistinctive and has been investigated in a specially designed test equipment between 500°C and 620°C. The power plant conditions were simulated with a flowing and pressurized (80 bar) combustion gas on the inner side of the tube, which contains water (H2O) and carbon dioxide (CO2). On the outer side, tube material was exposed to air. Oxides that formed on the air side under dual atmosphere conditions were significantly different from the oxide scales formed when the alloy was exposed to air only. It is assumed that the anomalous corrosion behavior during the dual atmosphere exposure is due to hydrogen and carbon diffusion through the bulk alloy from the combustion gas side to the air side. Both species are produced when the material reacts with the gas phase. Because of its high diffusivity, hydrogen is thought to affect the corrosion process on the air side from the beginning of the corrosion exposure, whereas carbon reaches the opposite side after a considerably longer time period.
High‐temperature KCl‐induced corrosion of high Cr and Ni alloys investigated by in‐situ diffraction
(2024)
High‐temperature KCl‐induced corrosion in laboratory air was observed in situ utilizing X‐ray diffraction. High Cr‐containing model alloys (Fe‐13Cr, Fe‐18Cr‐12Ni, and Fe‐25Cr‐20Ni) were coated with KCl and exposed to dry air at 560°C. KCl‐free alloys were studied in the equivalent atmosphere as a reference. After exposure to KCl‐free environments, all alloys showed the formation of very thin oxide layers, indicating good corrosion resistance. In contrast, KCl‐bearing alloys showed distinct damage after exposure.
Thin Sol-Gel Alumina Coating as Protection of a 9% Cr Steel Against Flue Gas Corrosion at 650 °C
(2018)
Samples of sol-gel alumina coated and uncoated P92 steel were exposed to flue gas at 650 °C for 300 h. As result of this treatment a 50 µm thick bi-layered oxide scale had formed on the surface of the uncoated sample. Below the scale a 40 µm thick inner oxidation zone was detected. In contrast, the porous, micron thick alumina coating enabled the formation of a chromium oxide scale with a thickness of some nanometers at the interface between steel substrate and coating. In this case high temperature corrosion of the steel was prevented so far.
The paper presents the microstructure, chemical and phase composition of thin scale, obtained as a result of high temperature corrosion of X20Cr13 stainless steel. Samples were exposed to gas atmosphere of the following composition: 0.25 vol.% of SO2 and 99.75 vol.% of Ar at 600 °C for 5 h. As a consequence, thin compact scale was formed on steel surface.
This scale consisted of three different zones. An amorphous zone was formed close to steel surface. Then, nanocrystalline Zone could be observed. Finally, larger grains were formed during the corrosion process. The analysis of the chemical composition revealed higher concentration of chromium near steel surface. In contrast, to chromium, the content of iron, increased near the scale surface. It was found out that the (Cr, Mn, Fe)5O12 phase appeared in the thin scale.