Aluminium alloy 6060 is typical of a family of Al-Mg-Si extrusion alloys, which are considered weldable only
when using an appropriate filler alloy such as 4043 (Al-5Si) or 5356 (Al-5Mg). This study concerns the
thermal analysis and solidification path determination of aluminium alloy 6060 diluted with variable amounts
of 4043. Casting of controlled mixtures of alloys 6060 and 4043 was used to simulate different weld dilutions
in order to facilitate thermal analysis. Thermal analysis and metallography were applied in order to reveal
solidification reactions and phases, and allow calculation of solid fraction versus temperature curves.
Although the liquidus temperature was little affected, different phases formed with increased 4043 dilution,
with a trend toward lower temperature reactions and a larger fraction interdendritic constituent.
The capabilities of non-destructive testing (NDT) methods for defect detection in civil engineering are characterized by their different penetration depth, resolution and sensitivity to material properties. Therefore, in many cases multi-sensor NDT has to be performed, producing large data sets that require an efficient data evaluation framework. In this work an image fusion methodology is proposed based on unsupervised clustering methods. Their performance is evaluated on ground penetrating radar and infrared thermography data from laboratory concrete specimens with different simulated near-surface defects. It is shown that clustering could effectively partition the data for further feature level-based data fusion by improving the detectability of defects simulating delamination, voids and localized water. A comparison with supervised symbol level fusion shows that clustering-based fusion outperforms this, especially in situations with very limited knowledge about the material properties and depths of the defects. Additionally, clustering is successfully applied in a case study where a multi-sensor NDT data set was automatically collected by a self-navigating mobile robot system.
Critical defects, also known as device killers, in wide bandgap semiconductors significantly affect the performance of power electronic devices. We used the methods imaging ellipsometry (IE) and white light interference microscopy (WLIM) in a hybrid optical metrology study for fast and non-destructive detection, classification, and characterisation of defects in 4H–SiC homoepitaxial layers on 4H–SiC substrates. Ellipsometry measurement results are confirmed by WLIM. They can be successfully applied for wafer characterisation already during production of SiC epilayers and for subsequent industrial quality control.
Methods to obtain weld discontinuities in spot-welded joints made of advanced high-strength steels
(2011)
Resistance spot welding is the major joining technique in mass car production. This applies in particular to high-strength steel and advanced high-strength steel (AHSS) joining of thin sheet steel components for lightweight body shell structures. Joining of AHSS in mass production might lead to weld discontinuities under certain circumstances. Those discontinuities in form of cracks might be an initial start of cracking in the spot-welded joints regarding fatigue loads. It is of great interest to figure out, if, in comparison to specimens without weld discontinuities, the crack initiating point changes and if the fatigue resistance might be reduced by the discontinuities. In this contribution, an overview of potential discontinuities is given. Their possible causes are discussed and means for their detection are highlighted. Among the possible causes of weld discontinuities, two major groups are distinguished: the welding parameters as primary influences in the welding process, and the production-specific influences as secondary ones. With emphasis on major cracks penetrating the weld nugget, these influences are analysed. Finally, a combination of extreme welding parameters with production-specific influences is chosen in order to establish a method which enables the preparation of fatigue test specimens with reproducible major cracks in different locations of the spot-welded joints. This method is than applied in order to prepare spot weld specimens for fatigue tests.
Thin plasma polymer films were deposited using the pulsed plasma mode. These plasma polymers should possess a more regular structure than those produced by the conventional continuous-wave (cw) mode, because of lower monomer fragmentation caused by the plasma pulses and the chemical chain propagation during the plasmaless (free!) periods. The thermoluminescence method was applied to functional groups carrying plasma polymer layers which are used in medical technology. Examples are formation of biocompatible, biosensoric and bioactive coatings or in metal polymer composites such as adhesion-promoting interlayers.
In addition to the use of the conventional X-ray Photoelectron Spectroscopy for thin film characterization, the new method of thermoluminescence was applied to characterize undesired defects and structural specifics produced in the polymer films by pp or cw plasma mode. The main areas of focus were oxygen-containing groups produced by post-plasma oxygen introduction via auto-oxidation, oxidation of implemented unsaturations and trapped radical sites known as typical irregular structures in plasma polymers.
Thermal cycling of a Ni-excess NiTi alloy was conducted between 50 °C and liquid nitrogen temperature to induce martensitic transformations and to reverse them after. The starting point was an annealed and slowly cooled state, the end point a sample thermally cycled 1500 times. Positron annihilation lifetime spectra and Coincidence Doppler Broadening profiles were obtained in various states and at various tem- peratures. It was found that the initial state was low in defects with positron lifetimes close to that of bulk NiTi. Cycling lead to a continuous build-up of a defect structure up to 20 0 −50 0 cycles after which saturation was reached. Two types of defects created during cycling were identified, namely pure dislo- cations and vacancies attached to dislocations.
The in situ analysis of the damage evolution in a metal Matrix composite (MMC) using synchrotron X-ray refraction radiography (SXRR) is presented. The investigated material is an Al alloy (6061)/10 vol% Al2O3 MMC after T6 heat treatment.
In an interrupted tensile test the gauge section of dog bone-shaped specimens is imaged in different states of tensile loading. On the basis of the SXRR images, the relative change of the specific surface (proportional to the amount of damage) in the course of tensile loading was analyzed. It could be shown that the damage can be detected by SXRR already at a stage of tensile loading, in which no Observation of damage is possible with radiographic absorption-based imaging methods.
Moreover, the quantitative analysis of the SXRR images reveals that the amount of damage increases homogeneously by an average of 25% with respect to the Initial state. To corroborate the experimental findings, the damage distribution was imaged in 3D after the final tensile loading by synchrotron X-ray refraction computed tomography (SXRCT) and absorption-based synchrotron X-ray computed tomography (SXCT). It could be evidenced that defects and damages cause pronounced indications in the SXRCT images.
The paper presents a numerical method to detect and characterise defects and inhomogeneities by means of active thermography. The objective was to determine the wall thickness of structure elements with an inaccessible back wall, e.g., elements of pipes or containers. As test specimens we used PVC samples with the thickness of about 2 cm that had spatial variations in the back wall geometry. Flash lamps provided the heating. To measure the thickness of the wall, we employed the LevenbergMarquardt method, which we applied here to experimental thermographic data for non-destructive testing. We started the inversion procedure by making a rough first estimation of the back wall geometry following the echo defect shape method, and then we calculated the thickness of the back wall. We found reasonable reconstruction results which differed from the real value significantly below 1 mm at the defect centre, whereas the error wais increased at the edge of the defect, depending on its shape and depth.