Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (21)
- Posterpräsentation (3)
- Buchkapitel (2)
- Vortrag (2)
Sprache
- Englisch (28)
Schlagworte
- Surface modification (28) (entfernen)
Organisationseinheit der BAM
- 6 Materialchemie (5)
- 9 Komponentensicherheit (4)
- 6.2 Material- und Oberflächentechnologien (3)
- 9.3 Schweißtechnische Fertigungsverfahren (2)
- 9.6 Additive Fertigung metallischer Komponenten (2)
- 1 Analytische Chemie; Referenzmaterialien (1)
- 1.2 Biophotonik (1)
- 5 Werkstofftechnik (1)
- 5.3 Polymere Verbundwerkstoffe (1)
- 6.1 Oberflächen- und Dünnschichtanalyse (1)
Eingeladener Vortrag
- nein (3)
Among new types of plasma processes, the underwater plasma is one of the most attractive methods for functionalization of polymer surfaces. The interesting features of plasma solution system are that the material surfaces to be modified remain in contact with the plasma-moderated solution. The role of plasma-moderated liquids, allows the reach of the reactive species through solution onto the geometrically hindered sites. The UV radiation produced in plasma formation helps in generating additional excited, ionized, and dissociated molecules and species in the reaction solution. An interesting feature of the technique is its flexibility to use a wide variety of additives as or in solution system. This allows us to create a selective or monotype functionalization of material surfaces. Such system was studied for the selective hydroxyl functionalization of polypropylene surface. The oxidation of polymer surfaces and the introduction of O-containing functional groups by underwater plasma was found to exceed concentrations typically achieved in oxygen low-pressure gas discharge plasmas up-to two-folds (maximal 56 O/100 C). The fraction of OH groups among all O-containing moieties amounts from 25 to 40% in comparison to that in the gas plasma of about 10% OH groups. Addition of hydrogen peroxide into this same system increases the fraction of C—O bonds up to 75% (27-OH/100 O). A study was focused to optimize the role of hydrogen peroxide on the efficiency of oxidation and selectivity with chemical derivatization with respect to the formation of mono-sort hydroxyl functionalities, calculated using a chemical derivatization technique.
Plasma chemical methods are well suited for introducing functional groups to the surfaces of chemically inert polymers such as polyolefins. However, a broad variety of functional groups are often formed. Unfortunately, for further chemical processing such as grafting of molecules for advanced applications a highly dense monotype functionalized polyolefin surface is needed. Therefore, the main task was to develop a selective surface functionalization process, which formed preferably only a single type of functional groups at the surface in high concentration. Amongst the novel plasma methods, the underwater plasma process (UWP) is one of most attractive options to solve the problem of monotype functionalization. Such plasma is an efficient source of ions, electrons, UV-radiation, high-frequency shock waves, radicals such as hydroxyl radical, and reactive neutral molecules such as hydrogen peroxide. In contrast to established gas phase glow discharge processes, the water phase limits the particle and radiation energies and thus the energy input into the polymer. By virtue of the liquid water environment, which moderates highly energetic plasma species, extensive oxidation, degradation, cross-linking and radical formation on the polymer are more limited as compared to gas plasma exposure. The variety of plasma produced species in the water phase is also much smaller because of the limited reaction possibilities of the plasma with water. The possibility to admix a broad variety of chemical additives makes underwater plasma even more attractive. Hydrogen peroxide and the catalyst (Fe-ZSM5) should influence and increase the equilibrium concentration of OH radicals in the underwater plasma process. It was found that these radicals played a very important role in OH functionalization of polyolefin surfaces. Hydrogen peroxide was identified to be the most prominent precursor for OH group formation in the UWP. The catalyst would affect the steady state of OH radical formation and its reaction with the substrate surface and thus accelerates the functionalization process.
Imaging ToF-SIMS has been applied to characterize the surface chemistry variations across small areas produced by a DBD-type plasma printing technique on a BOPP substrate using pure nitrogen and a nitrogen-hydrogen gas mixture. CH4N+ and CNO- secondary ions are detected with high yields remote from the discharge region. They are discussed to be due to surface modifications of the substrate by metastable gas-phase species. On the other hand, surface species exist that are preferentially formed by reactions of the substrate with short-lived species which are only present close to the plasma discharge region. A C3H8O+ secondary fragment ion is assumed to be a key fragment of such a surface species.
The X-ray-induced sample damage during mono XPS analysis of an oxygen-plasma-oxidized and subsequently wet-chemically reduced poly(propylene) film was investigated as a showcase for plasma-modified or plasma-deposited samples. By doing this, the degradation index approach as introduced by Beamson and Briggs in the Scienta ESCA300 high-resolution XPS database of organic polymers has been adopted. As to be expected, the sample degrades by loosing oxygen as revealed by observation of decreasing O/C and COR/Csum ratios. However, the X-ray degradation indices are definitely higher than those of conventional reference polymers. Moreover, the COR/Csum degradation index is significantly higher in comparison with one obtained for the O/C ratio. In that context, there is no difference between the plasma sample and a conventional poly(vinyl alcohol) polymer. It is concluded that for reliable quantitative surface chemical analysis, the quality of spectra in terms of acquisition times must be optimized aimed to a minimization of X-ray degradation. Finally, it is proposed to describe the photon flux of an X-ray gun in an XPS experiment, which defines the degradation rate at the end, by using the sample current simply measured with a carefully grounded sputter-cleaned reference silver sample.
Polypropylene supports were functionalized by plasma-deposition of polymeric allylamine layers. The surface amino groups generated were wet-chemically reacted with xanthene dyes resulting in fluorescent polymer films. The effect of polymer-attachment of the dyes on their emission features was studied fluorometrically and different methods were tested to improve the fluorescence properties of the films. Modification with cucurbit[6]uril (CB6) yields a moderately enhanced fluorescence as well as an improved photostability. The observed effect is most likely due to CB6-induced rigidization of the linker molecules which seems to reduce fluorescence quenching dyedye and fluorophoresurface interactions.
A novel low-pressure radio-frequency plasma treatment protocol was developed to achieve the effective through-thickness surface modification of large porous poly (d,l-lactide) (PDLLA) polymer scaffolds using air or water: ammonia plasma treatments. Polymer films were modified as controls. Scanning electron micrographs and maximum bubble point measurements demonstrated that the PDLLA foams have the high porosity, void fraction and interconnected pores required for use as tissue engineering scaffolds. The polymer surface of the virgin polymer does contain acidic functional groups but is hydrophobic.
Following exposure to air or water: ammonia plasma, an increased number of polar functional groups and improved wetting behaviour, i.e. hydrophilicity, of wet surfaces was detected. The number of polar surface functional groups increased (hence the decrease in water contact angles) with increasing exposure time to plasma. The change in surface composition and wettablility of wet polymer constructs was characterised by zeta potential and contact angle measurements. The hydrophobic recovery of the treated PDLLA polymer surfaces was also studied. Storage of the treated polymer constructs in ambient air caused an appreciable hydrophobic recovery, whereas in water only partial hydrophobic recovery occurred. However, in both cases the initial surface characteristics decay as function of time.
Surface-Enhanced Infrared Absorption (SEIRA) and Its Use in analysis of Plasma-Modified Surface
(1999)
The surface structure, in particular the surface roughness, and the surface chemistry of titanium implants influence their anchoring in bone. The aim of this study was to analyse metal-bone contact (MBC) after modification of the implant surface, using different materials for blasting. The surface modification of titanium was produced by blasting it with particles made of Al2O3 or bioceramics. The biological effects were then investigated experimentally using 27 rabbits, analysed after 7, 28 and 84 days after the implantation of titanium cylinders treated accordingly. The MBC showed a tendency for more bone after bioceramics were used as a blasting material, compared to Al2O3.