The presentation gives general information about the European Standard EN 16516 “Construction products – Assessment of release of dangerous substances – Determination of emissions into indoor air”. This test standard was developed based on the mandate M/366 of the European commission and is a horizontal reference method for the determination of volatile organic compounds (VOC) from different classes of construction (building) products. Specific test conditions are to be selected by the product TCs (technical committees) in a way that a product is tested under its intended condition of use.
The test is based on the use of emission test chambers which are operated at constant air change rate and climate (23°C, 50 % r.h.) over 28 days. The standard defines the conditions and requirements for the measurement including loading factor, air change rate, sampling, analysis and calculation of emission rates of the substances. A 30 m³ reference room is described which is used to calculate air concentrations from the determined emission rates.
The standard EN 16516 enables the evaluation of construction products regarding their emissions into indoor air under defined and comparable conditions. The evaluation includes the determination of identified target compounds, non-identified target compounds, volatile carcinogenic compounds and the sum values TVOC, TSVOC and R.
Acoustics is an important aspect for large rooms especially in schools, kindergartens and offices. Foam tiles made from melamine resins are often used for acoustic insulation because they show good fire resistance and good thermal insulation properties. But they can emit formaldehyde. In Germany there are cases with a resulting indoor air concentration of higher than 100 µg/m³. In this study samples from two schools and one office were investigated. Additionally, new tiles were purchased and tested to evaluate the general potential as formaldehyde source.
Besides measurement of VOC emissions also the evaluation of odour emissions and the perceived intensity of odours gains in importance. Due to difficulties detected in the measurement method of the perceived intensity described in (ISO 16000-28, 2012) the introduction of “reference” odours will be recommended for the training of panellists and as basis for interlaboratory comparisons.
In order to generate the “reference” odours standard liquid substances were directly injected into the main gas flow provided to the panellists. One of the substances tested was ethyl acetate. A pre-evaluation was conducted with six untrained panellists and has shown that ethyl acetate is potentially suitable as reference odour. For further validation of those “reference” odours they additionally will be provided to and evaluated by trained panellists of well established-measurement institutes.
A fire in a five-storey apartment building was investigated experimentally and numerically. The room of origin of the fire was a living room in the second floor and the fire was started by a candle on a television set. The fire spread externally over the building faccade and internally along the staircase and affected all the flats above leading to two fatalities. It is estimated that the fire was discovered minutes after ignition and the fire service was called very shortly after the detection and was at the scene 9?min after the call. By this time large sections of the façade were on fire already. The rapid fire that spread over the façade and the staircase necessitated detailed investigations. Compliance of building products with the building regulations was investigated. One conclusion of the investigations was that the person who caused the fire by leaving the candle on the TV set unattended should not be held responsible for the two fatalities in the upper floors.
Building products: Determining and avoiding pollutants and odours - Results from a research project
(2007)
In this study 50 construction products were tested in emission test chambers according to the requirements of the AgBB-scheme: 7 acrylic and 6 silicone sealants, 6 paste-like synthetic resin plasters, 13 wood based products, 4 adhesives, 5 lacquers, 6 wall paints and 3 further construction products. VOC and odour emissions were tested on the 1st, 3rd, 10th, and 28th day. In addition to the VOC-measurements, a test procedure was developed to evaluate odour emission of construction products.This test is planned to be implemented into the AgBB-Scheme. A direct evaluation by a sensory panel in the emission test chamber was not possible. So the odour samples were collected in 300- litre tedlar bags which were evaluated later. Odour intensity of the samples was compared with different acetone concentrations. Within this study an interlaboratory comparison was conducted using the newly developed odour test method. Additionally, VVOC emissions, detection of carcinogenic compounds, repeatability of emission test chamber tests, and other issues are presented. This project has shown that construction products can be evaluated in accordance with the AgBB scheme. A sensory evaluation is intended to be introduced in the AgBB scheme. A method for this evaluation is described in this study. The test procedure should be enhanced and validated for practical utilisation.