Composite-overwrapped pressure vessels (COPV) are increasingly used in the transportation industry due to their high strength to mass ratio. Throughout the years, various designs were developed and found their applications. Currently, there are five designs, which can be subdivided into two main categories - with a load-sharing metal liner and with a non-load-sharing plastic liner. The main damage mechanism defining the lifetime of the first type is fatigue of the metal liner, whereas for the second type it is fatigue of the composite overwrap. Nevertheless, one damage type which may drastically reduce the lifetime of COPV is impact-induced damage. Therefore, this barely visible damage needs to be assessed in a non-destructive way to decide whether the pressure vessel can be further used or has to be put out of service. One of the possible methods is based on ultrasonic waves. In this contribution, both conventional ultrasonic testing (UT) by high-frequency bulk waves and wavenumber mapping by low frequency guided waves are used to evaluate impact damage. Wavenumber mapping techniques are first benchmarked on a simulated aluminium panel then applied to experimental measurements acquired on a delaminated aluminium-CFRP composite plate which corresponds to a structure of COPV with a load-sharing metal liner. The analysis of experimental data obtained from measurements of guided waves propagating in an aluminium-CFRP composite plate with impact-induced damage is performed. All approaches show similar performance in terms of quantification of damage size and depths while being applied to numerical data. The approaches used on the experimental data deliver an accurate estimate of the in-plane size of the large delamination at the aluminium-CFRP interface but only a rough estimate of its depth. Moreover, none of the wavenumber mapping techniques used in the study can quantify every delamination between CFRP plies caused by the impact, which is the case for conventional UT. This may be solved by using higher frequencies (shorter wavelengths) or more advanced signal processing techniques. All in all, it can be concluded that imaging of complex impact damage in fibre-reinforced composites based on wavenumber mapping is not straightforward and stays a challenging task.
A semi-automatic thermographic procedure for the assessment of the welded area of resistance projection welded joints has been developed. Currently, to assess the quality of RPW joints destructive tests are used and the more commonly used non-destructive technique is the ultrasonic one. The possibility for a quantitative evaluation of the welded area by thermographic technique has been proved by means of an innovative procedure applied on steel RPW joints with ‘as it’ surface conditions. Measurements obtained by thermography and ultrasound have been compared, to verify the developed procedure.
High resolution examination of safety-relevant parts in immersion tank testing with focussing probes is forming a main topic of modern non-destructive testing. For the usage of complex reconstruction methods and algorithms, an individual and detailed knowledge about the transmission behaviour of the used probes is essential, as this has a significant influence on the results of data reconstruction.
Especially the knowledge about position and diameter of the focal point is needed to achieve the highest possible sensitivity. Through the individual position of the beam axis within the examined volume, a four dimensional metro logical determination of the acoustical pressure (x, y, z, t) is necessary. With the measured data it is possible to draw interferences about the sound field and acoustical pressure distribution. The presented work realized a method of automatic determination of the beam axis, the position of focal point and the focal diameter to support individual testing setups and transducer characterization.
In respect of modern approaches in material sciences and highly increased
requirements on materials on safety relevant components, quality management
and non-destructive testing reclaims a steadily increased meaning. The
destructive meaning of measuring the degree of purity is defined in DIN EN 10247
through metallurgical investigations, especially microsections.
For and comparable, but non-destructive testing due ultrasonic testing, the material
the SEP 1927 is a well-defined industry standard. A novel and alternative way
of reference block construction was focused by this work. The proposed amendments,
regarding the manufacturing and machining, are less time and cost consuming.
Verified by measurements the presented reference block fits the same acoustical
characteristics and the requirements of the guideline.
With increased usage of highly demanded, modern materials on safety
relevant parts (e.g. railway wheel sets, generator shafts, turbine disks, medical
implants, etc.) comprehensive analyses regarding the quality of the material are
requested. This gives a focus to non-destructive methods using ultrasound immersion
tank testing for classifying the degree of purity. Two autonomous standards,
ASTM E588 and SEP 1927, have been established for the definition, execution and
evaluation for this high resolution ultrasonic measurements on steel products.
The propagation of ultrasonic waves and the resulting sound field are strongly
dependent on the acoustical properties of the inspected material and the geometry
of probes and specimen. The definition of the measurement setup and the evaluation
methods appear to differ significantly in the given standards. ASTM E588 and
SEP 1927 prescribe the requirement for surface roughness and probe selection, are
using threshold based methods for cleanliness detection, but differ in computation
for the degree of purity. This has been the motivation for a comparison between
both standards with the main focus on amplitude depth dependency and overall spatial
resolution taking the influence of different material characteristics, geometry of
the specimen and sound fields into account.
A performance comparison between the use of non-focusing and focusing probes
respective to the threshold based detection will be presented in this contribution. In
addition, the usage of complex reconstruction algorithms (e.g. SAFT, echo tomography)
is compared with the traditional approaches of inclusion detection and
estimation of the degree of purity
Applications of fibre reinforced plastic (FRP) composites in modern industries are increasing due to their considerable advantages such as light weight and excellent mechanical properties. Accordingly, importance of operational safety of modern structures made of advanced composites by ensuring the material quality has led to increasing demands for development of non-destructive evaluation (NDE) systems. In the context of a European project entitled “Validated Inspection Techniques for Composites in Energy Applications” (VITCEA), the aim is to develop and validate traceable procedures for novel NDE techniques with contrasting damage detection capabilities in energy related applications such as wind and marine turbine blades, nacelles, oil and gas flexible risers. Accordingly, VITCEA focuses on optimization of ultrasonic tests (UTs) for quantitative defect detection and quality characterization of FRP structures. In this context, the present study describes the ultrasound field in heterogeneous composite materials. The theoretical predictions are compared with simulation results obtained from CIVA a software package dedicated to NDT simulations based on the asymptotic ray theory.
This guideline was drafted following and complementing the norm ISO 22232-2:2020(E) to include air-coupled ultrasonic transducers. This document specifies the characteristics of probes used for non-destructive air-coupled ultrasonic testing with center frequencies above 20 kHz, with focusing or without focusing means.