The self-ignition of coal dust deposits and its subsequent smoldering combustion pose a high fire hazard to oxy-fuel power systems which burn fuels using pure oxygen for the sake of carbon capture and storage. The increasing risk of explosion in the gas-phase and self-ignition in the solid-phase for an oxygen enhanced combustion environment has not been well studied yet. In this work, the heterogeneous reactions of a bituminous coal dust are investigated by using a novel hot-basket apparatus with an emphasis on the roles of O2 and diluent gas in chemisorption and smoldering. Experiments show that increasing O2 mole fraction accelerates both self-ignition and the following smoldering combustion. On the other hand, the presence of CO2 increases the ignition temperature and reduces the maximum smoldering temperature. However, the promotion in the fire and explosion risk by elevating O2 mole fraction is substantially stronger than the retardation effected by presence of CO2. The emission-gas measurements show that the CO to CO2 ratio increases significantly after self-ignition, and CH4 counts for 1 % to 8 % of the total carbon emission. This research may help improve the understanding of heterogeneous coal combustion and the fire safety in oxy-fuel power systems.
Industrial fires and explosions initiating from self-ignition of combustible porous dust deposits represent a serious hazard for human beings, environment and industry. Understanding the fundamental basis of combustible dust ignition behaviours at different geometries is of importance to prevent and mitigate the accidental risks. A correlation of self-ignition temperatures (SITs) measured by hot-oven tests and minimum ignition temperatures of dust layers (MITLs) determined by hot-plate tests has been established previously. However, this analogy approach based on Frank-Kamenetzkii model is limited by ignoring the influence of oxygen diffusion. In this work, an improved method is developed by implementing a correction factor for the pre-exponential factor caused by the boundary geometry. This method is testified by comparing with experimental data, previous analogy method and numerical simulation. Results show that our proposed method performs a better predictability of MITLs and simplicity. The improved analogy method indicates that the different boundary geometries of a dust deposit significantly impact the apparent pre-exponential factor, while have an ignorable influence on the activation energy, which is also verified by numerical investigations. Furthermore, the numerical model with the corrected kinetic parameters provides a satisfactory explanation compared with experimental observations regarding to temperature and concentration evolutions of dust layers.
Self-ignition of coal dust deposits poses a higher risk of fires in oxygen-enriched oxy-fuel combustion systems. In this work, we develop a numerical method, using the commercial software COMSOL Multiphysics, to investigate self-ignition behaviour of coal dust accumulations with a main emphasis on the roles of oxygen, diluent gas and dust volume. A one-step 2nd-order reaction kinetic model considering both coal density and oxygen density is used to estimate reaction rate using the kinetic parameters from previously conducted hot-oven tests. This model is validated to predict the transient temperature and concentration profiles of South African coal dusts until ignition. The computed self-ignition temperatures of dust volumes show a good agreement with experimental results. In addition, it is found that the inhibiting effect of carbon dioxide is comparatively small and oxygen consumption increases dramatically after ignition. Parameter analysis shows that the heating value and kinetic parameters have a comparatively pronounced effect on self-ignition temperature. The model provides a satisfactory explanation for the dependence of self-ignition behaviour on gas atmospheres, thus helping to further understand the fire risk of self-ignition in oxy-fuel combustion systems.
Smouldering fires and explosions arising from self-ignition of coal dust deposits represent a serious hazard for human being, environment and industry. It is essential for plant operators to know the conditions (temperature, duration and quantity) at which storage will be safe. In this work, self-ignition behaviour of three bituminous coal dusts in large scales are theoretically studied, based on the experimental data via a standardized hot-basket apparatus. A comprehensive 2-D transient model is developed, using a 2nd-order reaction kinetics considering both coal and oxygen consumptions, to investigate self-ignition parameters of coal dust accumulations. The numerical model shows a less conservative prediction compared with the steady-state methods. The computational self-ignition temperature and ignition delay time show a satisfaction agreement with lab-scale experimental results. In addition, the influences of ambient temperature and moisture content are analysed. The result shows that the moisture content delays the ignition and a small variation of the ambient temperature nearby the critical condition will lead to a large difference of the ignition delay time.
Determination of measurement uncertainties in adiabatic hot-storage experiments for reactive dusts
(2013)
The formal kinetics of self-ignition of solid bulk materials theoretically can be derived from just one single adiabatic hot-storage test. The question arises how uncertainties in the measurements can be quantified and how these uncertainties affect the results of the subsequent predictions. Adiabatic and isoperibolic hot-storage basket tests were performed for samples of lignite coal, black coal, cork dust, a polymer dust, and wax-coated silicid acid. In the adiabatic experiments, the starting temperature and the temperature control of the oven were varied systematically to study the uncertainty margin of adiabatic tests. The apparent activation energy and the pre-exponential factor of the lumped reaction were derived from the adiabatic tests including average values and standard deviations and compared to isoperibolic experiments performed according to the European standard EN 15188. It could be shown that with a precise temperature control of the adiabatic oven combined with an automated computation of the maximum rate of temperature rise the uncertainty of the apparent activation energy can be limited to less than 10%.
Experiments were performed to investigate the self-ignition behaviour of accumulations of four different technical dusts at oxygen volume fractions ranging from 1.3 to 21%. For this purpose a laboratory oven used for hot storage testing was modified to allow flushing with the pre-mixed oxygen/nitrogen mixture of the desired composition. It was found that for all sample volumes investigated the self-ignition temperatures were higher the lower was the oxygen volume fraction. In addition, the type of reaction changed obviously, since the apparent activation energy significantly decreased at oxygen volume fractions below 6%. However, it was still possible to observe exothermic effects at oxygen volume fractions as low as 1.3%. A numerical model was established to simulate the process of self-ignition including the coupled heat and mass transfer within the dust accumulation using a finite element solver. The model consists of six balance equations for the heat transfer and the transport of five chemical species. It shows that the model reflects self-ignition in dust accumulations with satisfying accuracy, as long as the input data generated by preceding experiments are reliable.
Self-ignition Behaviour of Bulk Materials: How Reliable is the Extrapolation of Laboratory Tests?
(2022)
The self-ignition behaviour of bulks is usually determined with the aid of isoperibolic or adiabatic hot storage tests; the sample volumes here are typically in the range of approx. 100 cm³ to several litres. The extrapolation to technically relevant volumes holds, however, considerable uncertainties. To reduce these uncertainties, a test stand was set up that allows to investigation sample sizes of up to 1000 dm³. These allow the study of selfignition behavior closer to the conditions that prevail in practice. The suitability (or unsuitability) of the established methods (including dangerous goods classification tests) were to be demonstrated and influencing variables that cannot be measured on a laboratory scale were to be determined.
In addition, various analytical methods were used for the determination of reaction kinetic data of solid bulk materials and to predict the self-ignition behaviour of large storages. These are thermal analyses such as differential scanning calorimetry DSC, simultaneous thermal analysis STA as well as microcalorimetry for highprecision measurement of heat flows.
Complete test series using all mentioned test methods will be presented for crosslinked polyvinyl-pyrrolidone (PVP) and conclusions regarding the applicability of the extrapolation methods will be discussed. Hot storage tests up to semi-industrial scale and their combination with various thermoanalytical methods allow a much more precise prediction of the self-ignition behaviour of large bulks. A further promising approach to estimate their heat release rates, and hence, the risk of self-ignition under technical conditions, is the use of microcalorimetric methods.
Vorgestellt wird ein 2018 gestartetes Projekt zur Überprüfung der Extrapolation von im Labormaßstab ermittelten Selbstentzündungstemperaturen auf technisch relevante Volumina. Für die Ermittlung reaktionskinetischer Daten von Feststoffschüttungen stehen eine Reihe von Untersuchungsmethoden zur Verfügung. Dies sind thermische Analysen wie z.B. die differential scanning calorimetry DSC sowie Mikrokalorimetrie zur hochgenauen Messung von Wärmeströmen, bei denen sehr geringe Probenmengen zum Einsatz kommen. In der Regel wird das Selbstentzündungsverhalten jedoch mit Hilfe von isoperibolen oder adiabaten Warmlagerungsversuchen beurteilt, hier liegen die Probenvolumina üblicherweise im Bereich von ca. 100 cm³ bis zu einigen Litern. Die Extrapolation über mehrere Größenordnungen auf technische Volumina birgt Unsicherheiten, da mit Zunahme des Lagervolumens veränderte Start- und Randbedingungen vorliegen können. Zudem besteht die Möglichkeit, dass bei in technischen Lagern vorherrschenden niedrigen Temperaturen Reaktionen ablaufen, die in Standard- Laborversuchen nicht erfasst werden aber einen wesentlichen Einfluss auf das Selbstentzündungsverhalten aufweisen können. Hauptziel des Projektes ist es daher, die im Labormaßstab vorhandenen Prüfeinrichtungen durch einen Versuchsstand zur Untersuchung von Probengrößen von bis zu 1000 dm³ zu erweitern, die Eignung (oder Nichteignung) der etablierten Methoden nachzuweisen und im Labormaßstab nicht erfassbare Einflussgrößen zu ermitteln. Zudem sollen anhand der kleinskaligen Tests Entscheidungskriterien abgeleitet werden, ob eine Extrapolation nach den derzeit üblichen Methoden zulässig ist.
Self-ignition Behaviour of Bulk Materials: How Reliable is the Extrapolation of Laboratory Tests?
(2022)
The self-ignition behaviour of bulks is usually determined with the aid of isoperibolic or adiabatic hot storage tests; the sample volumes here are typically in the range of approx. 100 cm³ to several litres. The extrapolation to technically relevant volumes holds, however, considerable uncertainties. To reduce these uncertainties, a test stand was set up that allows to investigation sample sizes of up to 1000 dm³. These allow the study of selfignition behavior closer to the conditions that prevail in practice. The suitability (or unsuitability) of the established methods (including dangerous goods classification tests) were to be demonstrated and influencing variables that cannot be measured on a laboratory scale were to be determined.
In addition, various analytical methods were used for the determination of reaction kinetic data of solid bulk materials and to predict the self-ignition behaviour of large storages. These are thermal analyses such as differential scanning calorimetry DSC, simultaneous thermal analysis STA as well as microcalorimetry for highprecision measurement of heat flows.
Complete test series using all mentioned test methods will be presented for crosslinked polyvinyl-pyrrolidone (PVP) and conclusions regarding the applicability of the extrapolation methods will be discussed. Hot storage tests up to semi-industrial scale and their combination with various thermoanalytical methods allow a much more precise prediction of the self-ignition behaviour of large bulks. A further promising approach to estimate their heat release rates, and hence, the risk of self-ignition under technical conditions, is the use of microcalorimetric methods.
In der Regel wird das Selbstentzündungsverhalten mit Hilfe von isoperibolen oder adiabaten Warmlagerungsversuchen beurteilt, hier liegen die Probenvolumina üblicherweise im Bereich von ca. 100 cm3 bis zu einigen Litern. Die Extrapolation auf technisch relevante Volumina birgt jedoch erhebliche Unsicherheiten. Diese beruhen auf:
- Extrapolation über mehrere Größenordnungen,
- Limitierungen der verwendeten Extrapolationsmethode (enge Start- und Randbedingungen),
- dem unterschiedlichen Temperaturniveau der Laborversuche im Vergleich zu technischen Lagerungen, insbesondere der Einfluss des enthaltenen Wassers,
- nicht eindeutige Kriterien für Zündung/Nichtzündung,
- Einfluss verschiedener Extrapolationsverfahren,
- mit Hilfe von Laborversuchen nicht erfassbarer Reaktionen (Niedertemperaturoxidationen, Zersetzung, Autokatalyse etc.),
- Streuungen der Messergebnisse.
Diese Unsicherheiten zu verringern ist Inhalt des vorgestellten Forschungsprojektes. Hauptziele des Projektes sind daher, die im Labormaßstab vorhandenen Prüfeinrichtungen durch einen Versuchsstand zur Untersuchung von Probengrößen von bis zu 1000 dm3 zu erweitern, die Eignung (oder Nichteignung) der etablierten Methoden nachzuweisen und im Labormaßstab nicht erfassbare Einflussgrößen zu ermitteln. Zudem sollen anhand der kleinskaligen Tests Entscheidungskriterien abgeleitet werden, ob eine Extrapolation nach den derzeit üblichen Methoden zulässig ist.
Erste Ergebnisse des Projektes bestätigen, dass die Bestimmung des Selbstentzündungsverhaltens von Stäuben und Schüttgütern und insbesondere die Ermittlung reaktionskinetischer Daten mit erheblichen Unsicherheiten behaftet sind. Sowohl Warmlagefungsversuche im Labormaßstab als auch mit Hilfe verschiedener Methoden ausgewertete thermoanalytische Methoden lassen, insbesondere einzeln betrachtet, zum Teil nur bedingt verlässliche Aussagen über das Selbstentzündungsverhalten großer Schüttungen zu. Vollständige Versuchsreihen unter Nutzung aller vorgestellten Untersuchungsmethoden sollen präsentiert und abhängig vom Probenmaterial - Schlussfolgerungen hinsichtlich der Zulässigkeit der Extrapolationsmethoden diskutiert werden.