Filtern
Dokumenttyp
- Zeitschriftenartikel (2)
- Beitrag zu einem Tagungsband (2)
- Vortrag (1)
- Posterpräsentation (1)
Sprache
- Englisch (6)
Schlagworte
- Radiation-induced attenuation (6) (entfernen)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (1)
In this work, we present our results achieved in several research activities for development of distributed fiber optic radiation sensors using glass and polymer optical fibers. The findings show that both the measurement of the radiation-induced attenuation (RIA) along the entire sensing fiber and the accompanying change in the refractive index of the fiber core can be used for distributed radiation monitoring.
In this work, we present our results achieved in several research activities for development of fiber optic dosimeters. The findings show that both the measurement of the radiation-induced attenuation (RIA) along the entire sensing fiber and the accom panying change in the refractive index of the fiber core can be used for distributed radiation monitoring in the kGy and MGy range, respectively. Depending on the fiber type and material the RIA shows varying response to dose rates, environmental temperatures and the wavelength of the laser source used.
The paper presents the first complex study of Gamma radiation effects on a low-loss perfluorinated polymer optical fiber (PF-POF) based on Cytop® polymer. Influence of gamma radiation on fiber’s optical, mechanical and climatic performance is investigated. The radiation-induced attenuation (RIA) in the visible and near-infrared region (0.4 μm-1.7 mm) is measured and its origins are discussed. Besides attenuation increase, radiation is also shown to decrease the thermal degradation stability of the fiber and to increase its susceptibility to water. With regard to complex fiber transmission performance upon irradiation, the optimal operation wavelength region of PF-POF-based systems intended for use in Radiation environments is determined to be around 1.1 μm. On the other hand, the investigated fiber holds potential for low-cost RIA-based optical fiber dosimetry applications with sensitivity as high as 260 dBm⁻¹/kGy in the visible region.
Sensitivity of two commercial perfluorinated (PF) polymer optical fibers (POFs) to gamma radiation was measured, compared and exploited for dosimetry purposes. Fiber radiation induced attenuation (RIA) was found to be highly wavelength dependent and pronounced towards the UV part of the spectrum. PF-POFs were shown to be highly radiation sensitive and RIA-based on-line radiation monitoring with sensitivity as high as 135 dBm-1/kGy was demonstrated at 460 nm with co-extruded PF-POF. In addition, thanks to low inherent attenuation in the near-infrared region, possibility of distributed radiation detection with PF-POFs was demonstrated for the first time, utilizing optical time domain reflectometry.
Radiation-induced attenuation of perfluorinated polymer optical fibers for radiation monitoring
(2017)
Due to some of their unique properties, optical fiber dosimeters are attractive and extensively researched devices in several radiation-related areas. This work evaluates the Performance and potential of commercial perfluorinated polymer optical fibers (PF-POFs) for radiation Monitoring applications. Gamma radiation-induced attenuation (RIA) of two commercial PF-POFs is evaluated in the VIS spectral region. Influence of a dose rate and temperature on RIA measurement is investigated, along with defect stability and measurement repeatability. Co-extruded PF-POFs are identified as more suitable for radiation monitoring applications due to lower dose-rate dependence.
With co-extruded PF-POF, RIA measurement holds potential for highly-sensitive radiation Monitoring with good reproducibility. The results show that operation in the blue part of the spectrum provides most favorable performance in terms of the largest nominal Radiation sensitivity, lower temperature, and dose-rate dependence as well as higher defect stability. We demonstrate for the first time to our knowledge, that PF-POFs can be used for distributed detection of radiation with doses down to tens of Grays. The off-the-shelf, user-friendly PF-POF could be of interest as a cheap, disposable sensor for various applications, especially of a more qualitative nature.