Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (19)
- Beitrag zu einem Tagungsband (6)
- Zeitschriftenartikel (5)
- Posterpräsentation (3)
- Beitrag zu einem Sammelband (2)
- Buchkapitel (1)
Schlagworte
- Offshore (36) (entfernen)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (19)
- 7.2 Ingenieurbau (11)
- 7.6 Korrosion und Korrosionsschutz (8)
- 9 Komponentensicherheit (8)
- 9.0 Abteilungsleitung und andere (7)
- 9.4 Integrität von Schweißverbindungen (7)
- 7.4 Baustofftechnologie (3)
- 8 Zerstörungsfreie Prüfung (3)
- 9.2 Versuchsanlagen und Prüftechnik (3)
- 7.1 Baustoffe (2)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (19)
This presentation discusses the potentials of probabilistic methods in offshore foundation installation, from the perspective of probabilistic ground models and data-driven site characterization. We discuss about methodologies for utilizing site-specific geotechnical (CPT) and geological data, aiming to construct an integrated ground model that can predict stratigraphic profiles and useful for geotechnical design parameters at any location within a 3D domain. The predicted parameters and stratigraphy are then used to predict the probability of potential pile tip damage, upon collision with a boulder.
The development of offshore wind turbines (WTGs) presents many challenges in terms of safe operation over extended periods of time. One of these is the corrosive environment towards metallic materials, which can lead to a loss of material thickness and thus to a deterioration of mechanical performances, especially the strength of infrastructures. This can be counteracted by painting and cathodic protection (CP). Much research has already been done in this area about inhibiting the corrosion process. However, gaps exist regarding free corrosion. This plays a greater role especially for time intervals during the installation of the systems and their maintenance, during which often no CP can be operated. This is especially true for areas where painting surfaces is impossible e.g., sediment areas. This problem is exacerbated by the different corrosion rates caused by the different zones (water and sediment), with their different amounts of dissolved oxygen.
This presentation deals with experiments in artificial seawater and sediment. Classical S355J2 steel samples in the form of coupons were fitted with welding wires that carried out the electrical contact to the outer side of the basin. Inside the basins, the specimens are stored in different zones like water and sediment which should simulate the foundation situation of monopiles. The mass loss was determined gravimetrically, elemental currents between specimens in water and sediment were measured and electrochemical investigations were carried out. The influences of the zones, based on different solved oxygen contents, and the rolling skin towards the corrosion behavior of the mild steel samples were determined in this work. Especially the influence of the sediment showed unexpected behavior, determined by electrochemical investigations. These results allow better conclusions to be drawn about the corrosion behavior of low alloy steels in offshore environments used in sediment and seawater, which cannot always be protected.
Maritime exposure poses particular challenges for corrosion
protection in plant construction. In addition to the right choice
of materials, special design features that can have an impact
on corrosion resistance must also be taken into account to
ensure long-lasting corrosion protection. In practice, structural
crevice arrangements are unavoidable, and therefore the
crevice corrosion resistances of stainless steels are of
particular importance. These and other influences are being
investigated in this joint project.
In the maritime context of offshore operation, corrosion, in combination with the materials used, poses a particular challenge to ensure safe operation over long indefinite periods and to minimise susceptibility to failure. Until today, only a few corrosion protection systems have proven themselves for the interaction of efficiency, installation, and maintenance in the offshore sector. In addition, available corrosion test methods sometimes have major deficits about conclusions of the durability. Therefore, there is more research and development needed.
The flagship project H2Mare of the Federal Ministry of Education and Research aims to enable the production of green hydrogen and PtX products at high seas. Research is being driven forward by the partners in four individual projects, where BAM is involved in two.
In PtX-Wind, major kinds of corrosion attacks at offshore constructions are characterized and investigated, and suitable corrosion protection measures determined. In TransferWind, attention focusses on transferring scientific results into standardization.
This poster at the H2Mare Conference 2023 presents an overview of the investigation methods and contribution of the department “Corrosion and Corrosion Protection”.
Offshore wind turbines (OWT) are a major goal of the energy strategy of Germany encompassing the increase of the installed wind power. OWT components are manufactured from welded steel plates with thicknesses up to 200 mm. The underlying standards and technical recommendations for construction of OWTs encompass specifications of so-called minimum waiting time (MWT) before non-destructive testing of the weld joints is allowed. Reason is the increased risk of time-delayed hydrogen assisted cold cracking as hydrogen diffusion is very slow due to the very thick plates. The strict consideration of those long MWT up to 48 h during the construction of OWTs leads to significant financial burden (like disproportionately high costs for installer ships as well as storage problems (onshore)). In this study, weld joints made of S355 ML were examined in comparison with the offshore steel grade S460 G2+M. The aim was to optimize, i.e., reduce, the MWT before NDT considering varied heat input, hydrogen concentration and using self-restraint weld tests. This would significantly reduce the manufacturing time and costs of OWT construction. To quantify the necessary delay time until hydrogen-assisted cold cracks appear, acoustic emission analysis was applied directly after welding for at least 48 h.
Remediation of Cracks Formed in Grouted Connections of Offshore Energy Structures under Static Loads
(2018)
The future energy demand necessitates the exploration of all potential energy sources both onshore and offshore. Global trend has shifted towards offshore energy, which can be obtained from either carbon intensive or renewable options, hence requiring structures such as rigs, platforms, and monopiles. Most of these structures adopt easily installable construction techniques, where lower foundation need to be connected with the super structure by mean of grouted composite joints. Generally, these composite connections have exterior sleeve, interior pile and infill grout. Being located in remote offshore conditions, connections can experience considerable adverse loading during their lifetimes. Degradations were reported inside similar connections, which were installed in last three decades. Besides, grouting in the offshore sites may often be proven difficult, which eventually leads to reduced capacity of connections in the long run. Thus, repair and rehabilitation of such connections should be planned ahead to minimize operational delays and costs in the future. This study aims at characterizing the nature of crack generation in grouted connections and thereby identifying the potential of repair using suitable repair material. Scaled grouted joints were manufactured using a novel mold, and connections were loaded under static load to visualize the main failure pattern. The failure mechanism and loading capacity are found compatible to previous results from earlier literature. Grouted connection was then repaired using cementitious injectable grout. The effectiveness of the repair system is also discussed.
Remediation of Cracks Formed in Grouted Connections of Offshore Energy Structures under Static Loads
(2018)
The future energy demand necessitates the exploration of all potential energy sources both onshore and offshore. Global trend has shifted towards offshore energy, which can be obtained from either carbon intensive or renewable options, hence requiring structures such as rigs, platforms, and monopiles. Most of these structures adopt easily installable construction techniques, where lower foundation need to be connected with the super structure by mean of grouted composite joints. Generally, these composite connections have exterior sleeve, interior pile and infill grout. Being located in remote offshore conditions, connections can experience considerable adverse loading during their lifetimes. Degradations were reported inside similar connections, which were installed in last three decades. Besides, grouting in the offshore sites may often be proven difficult, which eventually leads to reduced capacity of connections in the long run. Thus, repair and rehabilitation of such connections should be planned ahead to minimize operational delays and costs in the future. This study aims at characterizing the nature of crack generation in grouted connections and thereby identifying the potential of repair using suitable repair material. Scaled grouted joints were manufactured using a novel mold, and connections were loaded under static load to visualize the main failure pattern. The failure mechanism and loading capacity are found compatible to previous results from earlier literature. Grouted connection was then repaired using cementitious injectable grout. The effectiveness of the repair system is also discussed.
Bei Monopfahlgründungen von Offshore-Windenergieanlagen wird die Verbindung zwischen Monopfahl und Übergangsstück als geschraubter Ringflansch ausgeführt. Die zunehmende Leistungsfähigkeit der Windenergieanlagen führt zu immer größeren Schnittgrößen in diesem Anschluss. In der Folge erhöhen sich nicht nur die Querschnittsabmessungen, sondern es kommen auch zunehmend größere Schrauben zum Einsatz. Da die einschlägigen Regelwerke zur Bemessung dieser Verbindungen nicht für Schrauben der Größen M64 oder M72 konzipiert wurden, stellt sich die Frage der Übertragbarkeit auf solche Anwendungsfälle.
Im Rahmen des Aufsatzes werden Einflüsse diskutiert, die eine Herabsetzung der Schraubentragfähigkeit verursachen könnten. Diese Einflüsse, vornehmlich geometrische Imperfektionen, werden systematisch untersucht und ergänzend in praxisrelevanten Beispielen bewertet. Die somit gewonnenen Erkenntnisse werden für die abschließende Beurteilung der großen Schrauben in Ringflanschverbindungen herangezogen.