Filtern
Erscheinungsjahr
Dokumenttyp
Schlagworte
- Masonry (24) (entfernen)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (1)
- 7.1 Baustoffe (1)
Building stones are porous media and they can deteriorate through moisture ingress and secondary damage such as crystallization of soluble salts. Not only is this due to the increasing number of flood events in the past years but also structural damages of houses from activity such as leakage or rising moisture (groundwater) are the main causes. The potential benefit of several nondestructive testing methods to assess water damage in building stone has been studied in a field-scale experiment. Three testing walls made of fired clay brick, sandstone, and spongilite were flooded and their drying behavior monitored using infrared thermography, complex resistivity, ground penetrating radar, and ultrasonics. The results were compared to the average moisture content determined by gravimetric weighing of the specimens. Qualitatively, the results of the different nondestructive testing methods matched well. But in terms of quantitative data, some scatter was observed and the results should be viewed with care. Collecting time-consuming calibration data would help to overcome this problem, but especially when dealing with historic building structures, this is not always possible in practice.
A number of very relevant processes for protection and reconstruction of buildings can be supported by controlled heating: elimination of pests without using hazardous Chemicals, drying and decontamination of timber and many other building materials. For this purpose, radio-frequency (RF) dielectric heating is an advantageous Option because the materials and structures can be heated directly by energy absorption in the volume, homogeneously and, if required, relatively fast.
Compared to microwaves, the penetration depths are usually much larger and the flexibility with respect to different materials is wider. Namely, heating can also be realized for dry materials because the dielectric loss is as not closely related to the presence of water as for microwave applications.
Ingenieurbauten des Bundesfernstraßenbereichs sind aufgrund ihrer Exposition an vielen Stellen besonders betroffen von Graffiti. Graffitischmierer nehmen hierbei keine Rücksicht auf die Art der Substratmaterialien, und besonders poröse Untergründe bereiten Schwierigkeiten bei der Reinigung. Um Baustoffoberflächen besser zu schützen und von Graffiti leichter reinigen zu können, wurden in den vergangen Jahren spezielle Prophylaxesysteme (Anti-Graffiti-Systeme, AGS) entwickelten. Für die Beurteilung der Funktionalität und Verwendbarkeit dieser Anti-Graffiti-Systeme wurden von der Bundesanstalt für Straßenwesen (BASt) eine neue Technische Prüfvorschrift und Technische Lieferbedingungen (TP/TL AGS-Beton) erarbeitet. Die TP/TL AGS-Beton gilt hierbei nur für die Beurteilung von AGS auf Betonuntergründen. In einer Forschungsstudie wurde untersucht, inwieweit die vorhandene Prüfvorschrift für Betonsubstrate auch auf andere Untergründe, z. B. Naturstein oder Klinker, angewendet werden kann. Weiterhin wurde untersucht, welche Faktoren eine Rolle bei der Reinigung von mit AGS behandelten verschiedenen Substraten spielen.
ONSITEFORMASONRY is a research project funded by the European Commission under the 5. Framework Programme 1998-2002 in the Thematic Programme: Energy, Environment and Sustainable Development and the Key Action: The City of Tomorrow and Cultural Heritage.
The main objective of the project is the development and improvement of methodologies for the evaluation of the structure of historic masonry Cultural Heritages. For effective restoration and conservation of historic buildings, a detailed assessment of the structural safety and physical damages of the masonry structure is required. Therefore, typical masonry damages and the most frequent pathologies in each region have been identified and summarised in a catalogue of problems and damages. Selected non-destructive (NDT) and minor-destructive (MDT) techniques are performed by the partners including the development of software packages for fast and automated data analysis. The strategy for an effective and useful combination of different NDT and MDT methods will be worked out considering the results of case studies and taking into account the experiences of the consortium members. Recommendations and guidelines for the application of the integrated methodologies will be developed in close co-operation with end-users.
Non-destructive and minor destructive testing methods enable a classification of historic structures, building processes, applied building technologies and materials. Therefore, these methods should be part of the global investigation of historic buildings which is usually required before the planning of any building intervention. The case study presented herein encompasses experimental work carried out at the St. Servatius Church in Quedlinburg, Germany. Within a comprehensive restoration campaign, non-destructive on-site investigations were carried out with radar and ultrasonics. The results were combined with plans, views and cores recorded in advance.
For the investigation of the complex inner structure of historic buildings, the application of radar has been increased during the last ten years. Although historic masonry in general is very inhomogeneous and although in some cases high absorption occurs due to enhanced moisture, radar has been successfully applied to get information on geometry, position of inclusions and about kind and size of existing damages. In this paper case studies will be presented concerning the localisation of metallic inclusions and the investigations of the structure of an exterior wall with a multiple leaf structure.