MIKE III apparatus tests were conducted to investigate the minimum ignition energy (MIE) of coal dusts in air and O2/CO2 atmospheres with and without small amount of CH4/H2. The O2 mole fraction (XO2) in the gas mixtures varied from 21% to 50% with the CH4/H2 mole fraction from 0 to 2%. Experimental result showed that MIE of coal dusts significantly decreases even by three orders of magnitude in mJ with increasing XO2 and the addition of CH4/H2. Compared with CH4, H2 had a relatively strong promotion effect on the spark ignition of coal dusts. The inhibiting effect of CO2 was found to be much stronger than N2, but this inhibiting effect of CO2 could be eliminated by 9% increment of XO2. The effect on MIE of coal dusts thus followed by the order: 9% increment of XO2 > CO2 replacing N2 > 2% CH4 or H2 addition. Moreover, two empirical models were used to estimate the MIE of hybrid dust-gas mixture (HMIE), and the results showed that calculated data can well reflect the promoting effect of elevated XO2 and flammable gas addition, and the inhibiting effect of inert gas
The explosion characteristics of anthracite and bituminous coals in O2/N2 ambience were experimentally studied via a 20-L spherical explosion chamber with various ignition energies of 2, 5 and 10 kJ. A novel method based on combustion duration time was proposed for the first time, with an emphasis on the determination of the limiting oxygen concentration (LOC). The values of LOC determined by the alternative method were almost consistent with those obtained by using the standardized overpressure method, where the LOCs were above 21.6%, 19.8%, and 13.2% for anthracite coal and 11.4%, 9.6%, and 9.0% for bituminous coal when the ignition energy is 2, 5, and 10 kJ, respectively. But the newly proposed method was found to be much less affected by the ignition energy compared with the standardized overpressure method, taking combustion duration time as an explosion criterion thus had a higher efficiency and required fewer experiments. The results also showed that as oxygen concentration decreases from 21.6% to 14.4%, the maximum explosion pressure decreases from 0.4334 MPa to 0.1034 MPa for anthracite coal and from 0.5664 MPa to 0.3981 MPa for bituminous coal, respectively. Moreover, the effect of ignition energy varied with varying volatile matter content and ignition mechanism of coal dusts. The higher the volatile content, the less sensitive it is to the ignition energy. The newly proposed method will provide a reference for the new standard development, hazard analysis, explosion prevention and suppression by involving the use of inert gases of combustible powder industries.