Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (25)
- Vortrag (13)
- Beitrag zu einem Tagungsband (7)
- Posterpräsentation (7)
- Beitrag zu einem Sammelband (2)
- Sonstiges (2)
- Dissertation (1)
Sprache
- Englisch (57)
Schlagworte
- Copper (57) (entfernen)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (16)
- 1.1 Anorganische Spurenanalytik (12)
- 7 Bauwerkssicherheit (12)
- 7.6 Korrosion und Korrosionsschutz (12)
- 1.5 Proteinanalytik (7)
- 5 Werkstofftechnik (2)
- 5.2 Metallische Hochtemperaturwerkstoffe (2)
- 6 Materialchemie (2)
- 6.1 Oberflächen- und Dünnschichtanalyse (2)
- P Präsident (2)
Eingeladener Vortrag
- nein (13)
Accurate and precise isotope ratio measurements of heavy elements are playing an increasinglyimportant role in modern analytical sciences and have numerous applications. Today, isotope ratio measurements are typically performed with two principal techniques: thermal ionization mass spectrometry (TIMS) and multiple collector-inductively coupled plasma mass spectrometry (MC-ICP-MS). To obtain accurate results by mass spectrometry, isotopic certified reference materials (iCRMs) are needed for mass bias correction and for the validation of the method used for analysis.Thus, it is of paramount importance to achieve measurement comparability of all data reported, and to assess measurement capability of each CRM producer/National Metrology Institute (NMI). Therefore, the international comparison (CCQM-P213) was performed to assess the analytical capabilities of NMIs for the accurate determination of copper isotope ratio delta values in high purity materials. The study was proposed by the coordinating laboratories, National Research Council Canada (NRC), National Institute of Standards and Technology (NIST), Bundesanstalt für Materialforschung und -prüfung (BAM) and Physikalisch-Technische Bundesanstalt (PTB), as an activity of the Isotope Ratio Working Group (IRWG) of the Consultative Committee for Amount of Substance - Metrology in Chemistry and Biology (CCQM). Participants included six NMIs and one designated institute (DI) from the six countries. Although no measurement method was prescribed by the coordinating laboratories, MC-ICP-MS with either standard-sample bracketing (SSB) or combined SSB with internal normalization (C-SSBIN) models for mass bias correction were recommended. Results obtained from the six NMIs and one DI were in good agreement.
Three methods for direct solid sampling of bulk material namely IR laser ablation, glow discharge and spark OES, were compared with respect to analytical figures of merit obtained for elemental analysis with atomic spectrometry. Matrices investigated were copper, pressed doped copper powder, and magnesium alloys. For the vast majority of analytes, statistical equivalence regarding precision (usually ≤ 5%) and the performance of the calibrations between the compared methods was demonstrated.
In this study, we developed a new immunoprecipitation method based on protein-coated nanodiamonds. Performing SDS-PAGE and using the SDS-PAGE buffer as an eluent showed that CER could be successfully enriched from human serum. Based on the copper determination with ICP-MS, the amount of bound CER on the nanodiamonds can be calculated. We could show the fulfilled mass balance of bound CER and CER in the supernatant after incubation with a known amount of CER. For isotope ratio analysis this method can be applied to compare ratios of the total copper content in human serum to copper ratios from CER enrichment.
Expression, purification and characterization of the recombinant cysteine-rich biomarker Hepcidin-25
(2018)
Hepcidin regulates iron homeostasis in response to inflammation, erythropoietic demand, and iron stores. The native state of hepcidin-25 is an attractive target for the development of a reliable analytical tool that can quantify the hepcidin concentration in biological samples and reveal iron metabolic disorders. Therefore, a selective immunoassay would have to discriminate between different types of hepcidin and quantify only hepcidin-25’s concentration. The peptide contains a well-defined β-sheets and a β-hairpin loop stabilized by four disulfide bonds. Recently, it was shown that hepcidin-25 contains an ATCUN motif at its N-terminus. This motif is known to have high affinity towards Cu2+ and Ni2+.
One of the aims of this study is to determine the three-dimensional (3D) structure of metal-bound hepcidin-25. Here, we present an optimized procedure for preparing natively folded hepcidin 25 (~2.80 kDa) and structural analysis of metal binding to hepcidin-25. Hepcidin was expressed as a His6-SUMO-hepcidin-25 fusion protein (~16.20 kDa) in Escherichia coli, Origami B strains, and purified as a soluble recombinant protein in three steps. After purification based on the nickel affinity chromatography, the purified His6-SUMO-hepcidin 25 fusion protein was cleaved by the SUMO-specific ULP1 protease. The liberated hepcidin 25 was further purified on a Superdex 30 16/600 column and folded in the last step of purification in the presence of glutathione. Freshly expressed hepcidin was kept in its reduced form to prevent misfolding and allow for efficient removal of the SUMO tag. The presence of natively folded hepcidin 25 after RP-HPLC was confirmed by ESI-MS and NMR spectroscopy. Based on published chemical shifts, we achieved a nearly complete assignment of the labeled and unlabeled hepcidin-25 at pH=3. Comparison of 1H chemical shifts and TOCSY spectra at pH=7 in the presence and absence of Ni2+ demonstrates that the metal binds at the N-terminus of hepcidin 25. Chemical shift changes due to metal complexation decrease further away from the metal binding site.
Hepcidin-25 regulates iron homeostasis in response to inflammation, erythropoietic demand and iron stores. The liver synthesizes three types of hepcidin, only hepcidin-25 indirectly regulates and coordinates use and storage of iron. Hepcidin-25 contains a well defined β-sheet and β-hairpin loop stabilized by four disulfide bonds. The N-terminus which plays a crucial role in the biological activity of hepcidin-25 was found to be disordered. The ATCUN motif sequence is present at the N-terminus (Asp-Thr-His). The ATCUN motif (H2N-X-X-His) binds Cu2+ and Ni2+ with high affinity and always contains histidine in its sequence. NMR provides an ideal tool to determine hepcidin-25’s threedimensional(3D) structure taking into account the Cu2+ and Ni2+ binding capacity of hepcidin’s ATCUN motif.
Comparison of 1H chemical shifts and TOCSY data in the presence and absence of Ni2+ demonstrates that the metal binds at the N-terminus of the hepcidin-25. Chemical shift changes due to metal complexation decrease further away from the metal binding site, with the smallest effect at phenylalanine [Phe-4], proline [Pro-5] and isoleucine [Ile-6].
Solution-doped metal powder pellets as well as aspirated liquids were used as calibration samples to analyze pure copper and zinc certified reference materials (CRMs) by femtosecond laser ablation ICP-MS. It was demonstrated that calibration by copper pellets resulted in relative deviations up to 20%, whereas fs-LA-ICP-MS among copper-based CRMs led to inaccuracies in the same range unless nominal mass fractions were chosen to be <3 mg/kg. Calibration by zinc pellets generally provided better accuracy. Depending on the analyte considered, deviations below 10% were obtained even for mass fractions close to the limit of quantification. Our data, therefore, indicate solution-doped metal powder pellets to be suitable as calibration samples for fs-LA-ICP-MS of metals. Furthermore, the utilization of liquid standards for calibration was found to result in stronger deviations of up to 50% for both copper and zinc samples which, in addition, turned out to be dependent on the plasma conditions.
Quantification of sulphur in copper metals by isotope dilution LA-ICP-MS using polyethylene frits
(2018)
Sulphur is one of the relevant impurities in copper and its alloys affecting their material properties. To ensure the quality of copper products, fast direct solid sampling techniques are very attractive. However, for the calibration suitable matrix reference materials are required. For the certification of such reference materials appropriate, SI-traceable analytical methods are essential. Therefore, a procedure was developed to quantify total sulphur in copper by combining the classical isotope dilution (ID) technique and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS).
Here, for the first time, polyethylene (PE) frits were used to prepare appropriate solid samples for the sulphur quantification in copper metals (alloyed/unalloyed) by isotope dilution LA-ICP-MS. The properties of the PE frit meet the requirements as porous material with high absorption efficiency, thermal and chemical resistance as well as low sulphur blank. Different copper reference materials were used to develop and validate the procedure. The copper samples were spiked with 34S, digested with nitric acid and then the digests were absorbed on PE frits. After drying, the frits were analysed by LA-ICP-IDMS using a Nd:YAG laser at 213 nm coupled to an ICP sector field mass spectrometer. It could be demonstrated, that the sample solution dispersed on the frits did not influence the 32S/34S ratio significantly even though the sulphur intensities were fluctuating along the scanned lines. Relative standard deviations of the isotope ratios were below 5 % in average between three line scans (except for the pure spike solution and procedure blank). The measurement results were validated by comparing them with the results obtained by conventional ICP-IDMS after analyte-matrix separation. Plotting the mass fraction of sulphur in copper obtained by LA-ICP-IDMS versus those obtained by ICP-IDMS yields a linear curve with a correlation coefficient of 0.9999 showing a strong agreement between both techniques.
The metrological traceability to the SI from the kg down to the sulphur mass fraction in copper is established by an unbroken chain of comparisons, each accompanied by an uncertainty budget. Thus, the measurement results are considered reliable, acceptable and comparable within the stated measurement uncertainty.