Filtern
Dokumenttyp
Schlagworte
- Chemometrics (29) (entfernen)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (11)
- 1.4 Prozessanalytik (8)
- 1.6 Anorganische Referenzmaterialien (3)
- 1.3 Instrumentelle Analytik (1)
- 1.7 Organische Spuren- und Lebensmittelanalytik (1)
- 5 Werkstofftechnik (1)
- 5.3 Polymere Verbundwerkstoffe (1)
- 8 Zerstörungsfreie Prüfung (1)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (1)
- P Präsident (1)
Medium-resolution nuclear magnetic resonance spectroscopy (MR-NMR) currently develops to an important analytical tool for both quality control and processmonitoring. In contrast to high-resolution onlineNMR (HR-NMR),MR-NMRcan be operated under rough environmental conditions. A continuous re-circulating stream of reaction mixture fromthe reaction vessel to the NMR spectrometer enables a non-invasive, volume integrating online analysis of reactants and products. Here, we investigate the esterification of 2,2,2-trifluoroethanol with acetic acid to 2,2,2-trifluoroethyl acetate both by 1H HR-NMR (500MHz) and 1H and 19F MRNMR (43MHz) as amodel system. The parallel online measurement is realised by splitting the flow,which allows the adjustment of quantitative and independent flow rates, both in the HR-NMR probe as well as in the MR-NMR probe, in addition to a fast bypass line back to the reactor. One of the fundamental acceptance criteria for online MR-MNR spectroscopy is a robust data treatment and evaluation strategy with the potential for automation. The MR-NMR spectra are treated by an automated baseline and phase correction using the minimum entropy method. The evaluation strategies comprise (i) direct integration, (ii) automated line fitting, (iii) indirect hard modelling (IHM) and (iv) partial least squares regression (PLS-R). To assess the potential of these evaluation strategies for MR-NMR, prediction results are compared with the line fitting data derived from the quantitative HR-NMR spectroscopy. Although, superior results are obtained from both IHM and PLS-R for 1H MR-NMR, especially the latter demands for elaborate data pretreatment, whereas IHM models needed no previous alignment.
Annually vast amounts of plastics are produced world-wide. However, recycling and waste management is still insufficient resulting in large quantities of plastics being released into the environment. Degradation by sunlight, mechanical and biological factors lead to the breakdown of this waste into little fragments. By convention particles smaller than 5 mm are referred to as microplastics (MP). The occurrence of MP has been reported by researchers virtually all around the globe. Gaining knowledge on MP is currently a time-consuming process because analysis mainly relies on micro-infrared and micro-Raman methods. Prior to that the particles need to undergo purification and enrichment. Thus, only small numbers and volumes of samples can be investigated. Here we tested NIR spectroscopy combined with a multivariate data analysis as a means of speeding up the process of MP analysis.
Experiments were performed using the most abundant polymers polyethylene, polypropylene, polyethylene terephthalate and polystyrene. MP samples were obtained by adding the cryomilled and sieved (<125 µm) particles to approximately 1 g of standard soil at 0,5–10 mass%. Spectra were recorded with a fiber optic reflection probe connected to a FT-NIR spectrometer. 5–10 spectra recorded of each sample were used for the calibration of chemometric models (partial least squares regression, PLSR). “Unknown” test samples were then used to test the model’s capability to predict the type and amount of polymer.
In samples containing 1–5 % of the polymers the prediction yielded the highest degree of agreement with the gravimetric reference values. At low polymer loads some false positive results in the identification were observed. Large amounts of polymers limited the prediction capability by a nonlinear behaviour of the absorption. Further testing was done with real world samples such as compost and washing machine filters. Even though the calibration did not account for these highly complex sample compositions, satisfactory results could be achieved.
An experimental investigation has been carried out to characterize and discriminate seven saffron samples and to verify their declared geographical origin using a voltammetric electronic tongue (VE-tongue). The ability of multivariable analysis methods such as Principal Component Analysis (PCA), Hierarchical Cluster Analysis (HCA) to classify the saffron samples according to their geographical origin have been investigated. A good discrimination has reached using PCA and HCA in the VE-tongue characterization case. Furthermore, cross validation and Partial Least Square (PLS) techniques were applied in order to build suitable management and prediction models for the determination of safranal concentration in saffron samples based on SPME-GC-MS and UV-Vis Spectrophotometry. The obtained results reveals that some relationships were established between the VE-tongue signal, SPMEGC-MS and UV-Vis spectrophotometry methods to predict safranal concentration levels in saffron samples by using the PLS model. In the light of these results, we can say that the proposed electronic system offer a fast, simple and efficient tool to recognize the declared geographical origin of the saffron samples.
In this work, the potential of laser-induced breakdown spectroscopy (LIBS) for discrimination and analysis of geological materials was examined. The research was focused on classification of mineral ores using their LIBS spectra prior to quantitative determination of copper. Quantitative analysis is not a trivial task in LIBS measurement because intensities of emission lines in laser-induced plasmas (LIP) are strongly affected by the sample matrix (matrix effect). To circumvent this effect, typically matrix-matched standards are used to obtain matrix-dependent calibration curves. If the sample set consists of a mixture of different matrices, even in this approach, the corresponding matrix has to be known prior to the downstream data analysis. For this categorization, the multielemental character of LIBS spectra can be of help. In this contribution, a principal component analysis (PCA) was employed on the measured data set to discriminate individual rocks as individual matrices against each other according to their overall elemental composition. Twenty-seven igneous rock samples were analyzed in the form of fine dust, classified and subsequently quantitatively analyzed. Two different LIBS setups in two laboratories were used to prove the reproducibility of classification and quantification. A superposition of partial calibration plots constructed from the individual clustered data displayed a large improvement in precision and accuracy compared to the calibration plot constructed from all ore samples. The classification of mineral samples with complex matrices can thus be recommended prior to LIBS system calibration and quantitative analysis.
The increasing pollution of terrestrial and aquatic ecosystems with plastic debris leads to the accumulation of microscopic plastic particles of still unknown amount. To monitor the degree of contamination analytical methods are urgently needed, which help to quantify microplastics (MP). Currently, time-costly purified materials enriched on filters are investigated both by micro-infrared spectroscopy and/or micro-Raman. Although yielding precise results, these techniques are time consuming, and are restricted to the analysis of a small part of the sample in the order of few micrograms. To overcome these problems, here we tested a macroscopic dimensioned NIR process-spectroscopic method in combination with chemometrics. For calibration, artificial MP/soil mixtures containing defined ratios of polyethylene, polyethylene terephthalate, polypropylene, and polystyrene with diameters < 125 µm were prepared and measured by a process FT-NIR spectrometer equipped with a fiber optic reflection probe. The resulting spectra were processed by chemometric models including support vector machine regression (SVR), and partial least squares discriminant analysis (PLS-DA). Validation of models by MP mixtures, MP-free soils and real-world samples, e.g. and fermenter residue, suggest a reliable detection and a possible classification of MP at levels above 0.5 to 1.0 mass% depending on the polymer. The benefit of the combined NIRS chemometric approach lies in the rapid assessment whether soil contains MP, without any chemical pre-treatment. The method can be used with larger sample volumes and even allows for an online prediction and thus meets the demand of a high-throughput method.
The project InPROMPT aims to establish a robust hydroformylation reaction process of the alkene n-dodecene to the aldehyde n-tridecanal using a rhodium complex as catalyst in the presence of syngas. This industrial relevant production process demands further research for optimization and expansion. For that purpose, the fiber optic coupled probe of a process Raman spectrometer is directly introduced in the product stream, which enables the recording of spectra within short control intervals.
A major industrial reaction based on homogeneous catalysis is hydroformylation for the production of aldehydes from alkenes and syngas. Hydroformylation in microemulsions, which is currently under investigation at Technische Universität Berlin on a mini-plant scale, was identified as a cost efficient approach which also enhances product selectivity. Herein, we present the application of online Raman spectroscopy on the reaction of 1-dodecene to 1-tridecanal within a microemulsion. To achieve a good representation of the operation range in the mini-plant with regard to concentrations of the reactants a design of experiments was used. Based on initial Raman spectra partial least squares regression (PLSR) models were calibrated for the prediction of 1-dodecene and 1-tridecanal. Limits of predictions arise from nonlinear correlations between Raman intensity and mass fractions of compounds in the microemulsion system. Furthermore, the prediction power of PLSR models becomes limited due to unexpected by-product formation. Application of the lab-scale derived calibration spectra and PLSR models on online spectra from a mini-plant operation yielded promising estimations of 1-tridecanal and acceptable predictions of 1-dodecene mass fractions suggesting Raman spectroscopy as a suitable technique for process analytics in microemulsions.
Due to the increasing presence of microplastic particles (MP) in the Environment and the unknown risks arising from them, there is an urgent need for analytical methods that allow for an efficient identification and quantification of microplastics (MP), i.e. particles < 5 mm, in environmental samples. So far, mostly timeconsuming (micro) infrared or micro-Raman spectroscopic methods are applied. Here an faster alternative Approach is presented based on a Raman processspectrometer with fiber-optical probes in combination with multivariate data analysis.
A process spectroscopic approach for the monitoring of microplastics in environmental samples
(2018)
The potential of Raman and NIR process-spectroscopic as a rapid approach for the estimation of microplastics (MP) in soil matrix were tested. For this purpose, artificial MP/soil mixture samples consisting of standard soils or sand with defined ratios of MP (0,5 – 10 mass% polymer) from polyethylene (PE), polypropylene (PP), polystyrene (PS) and polyethylene terephthalate (PET) were prepared. MP particles with diameters < 2 mm and < 125 µm were obtained from industrial polymer pellets after cryo-milling. Spectra of these mixtures were collected by (i) a process FT-NIR spectrometer equipped with a reflection probe, (ii) by a cw-process Raman spectrometer and (iii) by a time-gated Raman spectrometer using fiber-optic probes. The evaluation of process-spectra was performed by chemometric methods. Whereas MP could be detected by Raman spectroscopy in coastal sand at 0.5 mass%, in standard soil detection of MP was limited to 10 – 5 mass% with the large fraction, but samples containing particles of the 125µm mass-fraction yielded no positive result at all. One reason for the lacking sensitivity could be fluorescence by soil organic matter and thus, in a next test time-gated Raman spectroscopy was applied. However, although being indeed more sensitive to the small particles this method failed at MP < 5 mass% indicating that fluorescence was not the major problem. Finally, FT-NIR was tested. Depending on the polymer, MP contents of 0,5 or 1 mass%, respectively, could be detected in standard soils and polymers identified. Furthermore, this approach could be used for the investigation of mixtures of up to four polymers and in real-world samples from bio-waste fermenter residues.
Multivariate data analysis is a universal tool for the evaluation of process spectroscopic data. In process analytics, huge amounts of information are produced i) by the many variables contained in one spectrum often exceeding 1000 (wavenumbers, wavelength, shifts…), and ii) the high number of spectra that is generated within the measurement period. Multivariate data analysis, often also called Chemometrics, help to extract the relevant information which is needed to examine and even control processes. Therefore, calibration models must be precise and robust, and moreover, must cover a wide range of variation of factors posing an influence on the process.
In this pre-conference course an introduction to both, explorative data analysis by PCA (Principal Component Analysis), and regression analysis by the most frequently used method, i.e. PLSR (Partial Least Squares Regression) is given. In principal, all optical spectroscopic methods are suited for multivariate evaluation. It will be demonstrated that under certain preconditions, even process NMR spectra can be predicted by PLSR models.
At first, basic principles of multivariate data analysis will be provided. This includes a short introduction into the concept of model building and interpretation of results. Detailed aspects of data pretreatment and calibration & validation strategies for chemometric models will be provided with own data from NIR, Raman and NMR spectroscopy.
In a first example, the development of an online compatible method for the quantification of methanol in biodiesel by PLSR is presented. This also includes the classification of biodiesel feedstocks by PCA and statistical tools which allow for the estimation of a full uncertainty budget.
The Raman spectroscopic prediction of Hydroformylation reaction in a miniplant is used to discuss shortcomings and pitfalls which may occur with the transfer of off-line models to the real processes. Design of experiment and strategies for suitable lab-scale experiments are presented as a possible way to overcome problems.
In a third application the prediction of the reactants of an esterification reaction based on process NMR data is demonstrated.