Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (12)
- Zeitschriftenartikel (10)
- Vortrag (3)
- Posterpräsentation (1)
Schlagworte
- LIBS (20)
- Concrete (8)
- Chloride (7)
- Chlorine (4)
- Heterogeneity (4)
- Carbonation (3)
- Cement (3)
- Chemical analysis (3)
- Chlorides (3)
- Sodium (3)
- ASR (2)
- Alkali-Kieselsäure-Reaktion (2)
- Alkali-silica reaction (ASR) (2)
- Alkalis (2)
- Baustoffe (2)
- Baustoffuntersuchungen (2)
- Beton (2)
- Chlorid (2)
- Corrosion (2)
- Dauerhaftigkeit (2)
- Elementanalyse (2)
- Messsysteme (2)
- Mobiles LIBS (2)
- Natrium (2)
- Spectroscopy (2)
- Sulfur (2)
- 2D-map (1)
- AKR (1)
- Alkali silica reaction (ASR) (1)
- Alkali-silica-reaction (1)
- Bauwerksdiagnostik (1)
- Bauwerkserhaltung/Instandsetzung (1)
- Betonfahrbahndecke (1)
- Building materials (1)
- Building materials analysis (1)
- Calibration (1)
- Carbonatisierung (1)
- Chemische Analyse (1)
- Chemometrics (1)
- Chlor (1)
- Chloride ingress (1)
- Classification (1)
- Concrete cracking (1)
- Concrete deterioration (1)
- Condition assesment (1)
- Cracks (1)
- EM-clustering (1)
- Element analysis (1)
- Element mapping (1)
- Elemental analysis (1)
- Harmful substances (1)
- Identification (1)
- Ingress (1)
- Korrosion (1)
- Lebensdauer (1)
- MRFA (1)
- Nasschemie (1)
- Parkbauten (1)
- Potentiometric titration (1)
- Qualitätssicherung (1)
- Quantification (1)
- Quantitative concentration (1)
- RFA (1)
- Spektroskopie (1)
- Sulfates (1)
- Sulphate (1)
- Sulphur (1)
- Tausalz (1)
- Testing method (1)
- Titration (1)
- Validation (1)
- XRF (1)
- ZfP (1)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (3)
Laser-induced breakdown spectroscopy (LIBS) is a combination of laser ablation and optical emission spectroscopy. Due to the possibility of direct measurements on the sample surface with a minimum of sample preparation investigations of building materials can be conducted quite fast. In combination with a scanning technique (translation stage or scanning mirrors head) 2D element distributions of harmful species like chlorides and alkalis are evaluated with a sub-mm resolution. By scanning a surface of typically 100 mm x 100 mm the heterogeneity of the material may be considered. LIBS is capable to identify hot spots in element concentration with a resolution of 0.1 mm or even smaller. A LIBS-system for the on-site application on building materials is, in cooperation with system developers and companies which will use this technique for investigation on real structures, under test at BAM. We present an example. Further work will focus on providing guidelines to establish LIBS as a standard procedure for chemical investigations of building materials.
A big part of the infrastructure is made of concrete, which is a multiphase system made of cement, aggregates, water and pores. Concrete is often used in combination with steel as reinforced concrete. Environmental influences, especially the ingress of harmful ions in combination with the ingress of water, trigger different damage processes which reduce the designed lifetime of a structure. The ingress of chlorides from de-icing salt or sea water leads to corrosion of the reinforcement. In addition, the carbonation of the concrete may trigger the corrosion of the reinforcement. The ingress of alkalis from deicing salts may cause the expansion of the amorphous silica aggregates (alkali-silica reaction) through
formation of a swelling gel of calcium silicate hydrate if water is present. The ingress of sulphates may cause spalling of the concrete surface due to ettringite formation.
For the standard procedure in civil engineering cores are taken, cut in slices, grinded and the obtained homogenized powder is solved in acid and investigated by standard procedures.
BAM has developed the LIBS technique for the 2D evaluation of the chemical composition of concrete. The technique is established for automated laboratory use with high numbers of samples to investigate transport processes of harmful species (Cl-, CO2 , SO4 2-and alkalis) in concrete. Information about ingress depth and the quantitative values are important to estimate the remaining lifetime of the infrastructure. LIBS is a surface technique. To get information about the ingress depth, a drill core has to be taken and cut in the middle. The measurements are carried out at the cross section. The main advantages of LIBS are the direct measurement on the surface of the concrete, fast analysis (sample rate 100 Hz) with a spatial resolution of up to 100 µm, the consideration of the heterogeneity of the concrete and the possibility of automated measurements which save a lot of manpower and time. As an example the investigation of ingress profiles for standard diffusion and migration tests in civil engineering takes hours in comparison to just a few minutes using LIBS. At the same time a 2D-evaluation provides information about hot spots of elemental concentration which may not be found by standard methods.
The state of the art of LIBS technique for applications in civil engineering will be presented, including typical results of 2D investigation of concrete in laboratory. The performance is also demonstrated by examples for onsite applications using a mobile LIBS system. The road map to standardization is presented as well.
Laser induced breakdown spectroscopy (LIBS) - visualization of ion transport processes in concrete
(2014)
Laser induced breakdown spectroscopy (LIBS) is a combination of laser ablation and optical emission spectroscopy. Due to the possibility of direct measurements on the sample surface and a minimum of sample preparation investigations of building materials can be conducted quite fast. In combination with a scanning technique (translation stage or scanning mirrors head) the element distributions are evaluated with mm resolution. Thus the heterogeneity of the material may be considered. This is a significant advantage compared to standard procedures. LIBS measurements are also time and cost saving in comparison to standard methods. The automated measurement procedures minimize the liability for errors. All elements are detectable. Results can be quantified after calibration. At BAM LIBS has been successfully applied for the investigation of distribution and transport of different ions in building materials. Quantitative measurements are performed for chlorine, sodium, potassium, sulfur, lithium and hydrogen. In addition the identification of substances and the evaluation of quantitative ratios by means of an integrated marker are possible. An overview about the principle and the possibilities of LIBS investigations of building materials is presented and typical applications are shown. The LIBS technique is close to practical application on-site.
Laser Induced Breakdown Spectroscopy (LIBS) is a combination of laser ablation, plasma formation and optical emission spectroscopy. The possibility of direct measurements on the sample surface, the minimum of necessary sample preparation and the automated setup allows for fast investigations of building materials. In combination with a scanning technique (translation stage or scanning mirrors head) the element distribution can be evaluated in consideration of the material's heterogeneity. LIBS measurements are also time-and cost-saving. The ingress profile of chlorine on a 50mm diameter concrete core up to a depth of 50mm can be measured and evaluated in less than 10 minutes. The results are normally referred to the evaporated mass, which is approximately the cement mass of the specific concrete. As a completion to micro XRF measurements also light elements like sodium or hydrogen can be detected. The spatial resolution of the measurement may reach 50 ìm at a maximum measurement frequency of up to 100 Hz. On the basis of calibration curves, results can be quantified.
The laser induced breakdown spectroscopy (LIBS) gives an alternative to the standard techniques for the direct investigation of a building material. It utilize a high energy pulsed laser beam for ablation and vaporization of a small amount of material, a plasma is formed and the plasma radiation is investigated using optical emission spectroscopy. Due to the principal all elements are detectable during one measurement. In combination with a translation stage or scanner system the heterogeneity of concrete is considered in the results. Thus an element concentration may be correlated to the cement content. After calibration with a set of reference samples quantitative results are obtained. The system is automated and allows rapid measurements and minimizes the possibility of errors. At BAM a laboratory LIBS system has been successful applied for the investigation of transport processes of different ions in building materials. The spatial resolution of the measurement may rich 100 μm and the frequency of the measurements is 100 Hz. The concentration of chlorine, sulfur, carbon, sodium, potassium, lithium and hydrogen where quantitatively determined. A mobile system for on-site analysis on bridges or parking decks is available. It is a tool for the estimation of the condition of concrete structures and for quality assurance during concrete repair work on-site. In these work an overview of the possibilities of LIBS for automated investigation of building materials are given.
Laser-induced breakdown spectroscopy (LIBS) is a combination of plasma generation on the sample surface by a high power laser pulse and optical emission spectroscopy (OES). It is a direct measurement method without an extensive sample preparation. Concrete is a multi phase system. With LIBS it is possible to distinguish the different phases and based on that to correlate the chloride content to the cement mass. This is done by scanning the surface with a resolution of up to 0.1 mm. The high measurement frequency of 100 Hz or even higher allows the in-situ visualization of the chloride content over the measured area. With a calibration a quantification of chloride concentration is possible. As an example the LIBS measurement on a 50 mm by 70 mm area with a resolution of 0.5 mm and the visualization of the chloride distribution takes only 10 minutes. Additionally it is possible to evaluate the carbonation depth from the same measurement. Examples of practical application to determine the chloride-to-cement-content on concrete samples are presented. The possibilities and the limitations of LIBS are discussed.
In den letzten Jahren sind im deutschen Bundesautobahnnetz vermehrt AKR-Schäden an Betonfahrbahndecken aufgetreten. Ursächlich hierfür ist die Verwendung alkaliempfindlicher Gesteinskörnung. Dies führt bei gleichzeitiger Anwesenheit von Wasser infolge der Exposition der Fahrbahndecke und des alkalischen Milieus durch den Einsatz alkalireicher Portlandzemente bei der Betonherstellung zu einer Alkali-Kieselsäure-Reaktion (AKR). Zusätzlich wird der AKR-Schädigungsprozess in Betonfahrbahndecken durch den externen Tausalzeintrag (primär NaCl) im Winter begünstigt. Vor diesem Hintergrund kommt der Ermittlung des Tausalzeintrags in den Fahrbahndeckenbeton eine große Bedeutung zu.
Die Analyse des Tausalzeintrags erfolgte bisher ausschließlich nasschemisch an gemahlenen Bohrkernsegmenten. Nachteilig sind hierbei der relativ hohe prüftechnische Aufwand und die eingeschränkte Ortsauflösung. Der alternative Einsatz von LIBS (Laser-induced breakdown spectroscopy) eröffnet in diesem Kontext neue Möglichkeiten. So wird in diesem Beitrag anhand von Bohrkernen aus einem repräsentativen AKR-geschädigten BAB-Abschnitt exemplarisch die Vorgehensweise bei der LIBS-Analyse zur Ermittlung der Na- und Cl-Verteilung an vertikalen Schnittflächen von Bohrkernen aufgezeigt. Da der Tausalzeintrag primär über den Zementstein erfolgt, wurde der verfälschende Na-Grundgehalt der Gesteinskörnung mittels eines Ausschlusskriteriums (Ca-Gehalt) eliminiert. Vergleichend durchgeführte Cl-Mappings mit Mikroröntgenfluoreszenzanalyse sowie nasschemische Analysen belegen die Güte der durchgeführten LIBS-Messungen. Allerdings bedarf es bei der quantitativen Ermittlung des Natriumgehaltes in der Betonfahrbahndecke noch weitergehender Untersuchungen.
The composition of concrete determines its resistance to various degradation mechanisms such as ingress of ions, carbonation or reinforcement corrosion. Knowledge of the composition of the hardened concrete is therefore helpful to assess the remaining service life of an existing structure or evaluate the damage observed during inspections. For example, for most existing concrete structures the type of cement originally used is not known and must therefore be determined afterwards. This paper presents a preliminary study on the application of laser-induced breakdown spectroscopy (LIBS) to identify the type of cement. For this purpose, ten different types of cement were investigated. For every type, three cement paste prisms were produced: (i) prisms dried, ground and pressed into tablets, (ii) prisms dried and (iii) prisms untreated. LIBS measurements were performed with a diode-pumped low energy laser (1064 nm, 3 mJ, 1.5 ns, 100 Hz) in combination with two compact spectrometers which cover the UV and NIR spectral range. A reduced subset of spectral features was used to build a classification model based on linear discriminant analysis. The results show that the classification of homogenized pressed cement powder samples provides a high accuracy, however, factors such as a different sample matrix and moisture content can affect the accuracy of the classification. The study demonstrates that LIBS is a promising tool to identify the type of cement.
Bei der Erhaltung von Stahlbetonbauwerken ist der Chloridgehalt im Beton ein wichtiger Parameter zur Festlegung geeigneter Instandsetzungsmaßnahmen. Die bisher etablierten Verfahren basieren auf der nasschemischen Analyse einer Probe, Bohrmehl oder aufgemahlener Segmente eines Bohrkerns. Das Verfahren liefert einen Chloridgehalt je Tiefensegment, was mit einer starken Homogenisierung der Probe einhergeht, wodurch detaillierte Informationen zu Chloridunterschieden im Millimeterbereich verloren gehen. Eine alternative Methode ist die laserinduzierte Plasmaspektroskopie (LIBS), die nicht nur die quantitative ortsaufgelöste Bestimmung des Chloridgehalts im Bezug zur Zementmasse ermöglicht, sondern auch simultan detaillierte Informationen über die Verteilung vieler anderer chemischer Elemente liefert. Die räumliche Auflösung liegt in der Regel im Bereich von einigen Millimetern, kann aber bei Bedarf auf 0,1 mm oder weniger erhöht werden. Das neue Merkblatt B14 „Quantifizierung von Chlorid in Beton mit der laserinduzierten Plasmaspektroskopie (LIBS)“ der Deutschen Gesellschaft für Zerstörungsfreie Prüfungen (DGZfP) regelt und vereinheitlicht erstmals die zuverlässige und reproduzierbare Ermittlung des Chloridgehalts mit LIBS. In diesem Beitrag wird das Merkblatt vorgestellt und anhand praktischer Anwendungsbeispiele das Potenzial von LIBS für Fragestellungen in der Betonerhaltung verdeutlicht.
Cracks are always present in reinforced concrete structures. In the presented research, influence of mechanical cracks on chloride ingress is studied. A compact reinforced concrete specimen was designed, mimicking the cracking behaviour of beam elements. Cracks of different widths were induced by means of mechanical loading. These cracked specimens were then subjected to weekly cycles of wetting and drying with NaCl solution. After the exposure, the specimens were cut, and chloride distributions were determined using Laser Induced Breakdown Spectroscopy (LIBS), an innovative technique which enables simultaneous determination of different elements with high spatial resolution and minimal specimen preparation. By combining element distributions of different elements, it is possible to discriminate between coarse aggregate particles, and the mortar matrix. It was found that the wider the crack is, the higher the ingress of chloride ions. This was, however, different for two tested concrete mixes. Due to highly inhomogeneous chloride distribution around the cracks, use of fine-scale experimental techniques for chloride mapping is advised, based on the presented study.