Processing ultrasonic data by coda wave interferometry to monitor load tests of concrete beams
(2018)
Ultrasonic transmission measurements have been used for decades to monitor concrete elements, mostly on a laboratory scale. Recently, coda wave interferometry (CWI), a technique adapted from seismology, was introduced to civil engineering experiments. It can be used to reveal subtle changes in concrete laboratory samples and even large structural elements without having a transducer directly at the place where the change is taking place. Here, several load tests until failure on large posttensioned concrete beams have been monitored using networks of embedded transducers. To detect subtle effects at the beginning of the experiments and cope with severe changes due to cracking close to failure, the coda wave interferometry procedures had to be modified to an adapted step-wise approach. Using this methodology, we were able to monitor stress distribution and localize large cracks by a relatively simple technique. Implementation of this approach on selected real structures might help to make decisions in infrastructure asset management.
Zusammenfassung Im Rahmen eines Forschungsvorhabens an der RWTH Aachen wurden mehrere Spannbetondurchlaufträger bis zum Versagen belastetet. Neben umfangreicher konventioneller Messtechnik wurden zusätzlich innovative Messmethoden durch die Bundesanstalt für Materialforschung und –prüfung (BAM) getestet. Darunter waren eingebettete Ultraschall-Transducer, deren Daten mit einer neuartigen Methode, der Codawelleninterferometrie (CWI), ausgewertet wurden. Dieses Verfahren detektiert auch kleinste Änderungen im Signal und in der Wellengeschwindigkeit gegenüber einer Referenzmessung. Hiermit können Belastungs- und Strukturänderungen sowie Schäden sehr viel sensibler angezeigt werden als bei konventionellen Ultraschallmessungen. Durch eine Modifikation des Verfahrens mit gleitender Referenz können aber auch starke Veränderungen im Material, wie sie bei Bruchversuchen auftreten, erfasst werden. In den Versuchen gelang es mit Netzwerken aus bis zu 20 Ultraschall-Transducern, Spannungskonzentrationen und Rissbildungen qualitativ zu detektieren und zu verfolgen, ohne dass die Sensoren direkt am Ort der Änderung angebracht sein müssen.
The incorporation of colloidal quantum dots (QDs) into solid matrices, especially ionic salts, holds several advantages for industrial applications. Here, we demonstrated via absolute measurements of photoluminescence quantum yields (PL-QY) that the photoluminescence of aqueous CdTe QDs can be considerably increased upon incorporation into a salt matrix with a simple crystallization procedure. Enhancement factors of up to 2.8 and a PL-QY of 50 to 80%, both in NaCl crystals and incorporated in silicone matrices, were reached. The fact that the achievable PL enhancement factors depend strongly on PL-QY of the parent QDs can be described by the change of the dielectric surrounding and the passivation of the QD surface, modifying radiative and nonradiative rate constants. Time-resolved PL measurements revealed noncorrelating PL lifetimes and PL-QY, suggesting that weakly emissive QDs of the ensemble are more affected by the enhancement mechanism, thereby influencing PL-QY and PL lifetime in a different manner.
The present work shows results on elemental distribution analyses in Cu(In,Ga)Se2 thin films for solar cells performed by use of wavelength-dispersive and energy-dispersive X-ray spectrometry (EDX) in a scanning electron microscope, EDX in a transmission electron microscope, X-ray photoelectron, angle-dependent soft X-ray emission, secondary ion-mass (SIMS), time-of-flight SIMS, sputtered neutral mass, glow-discharge optical emission and glow-discharge mass, Auger electron, and Rutherford backscattering spectrometry, by use of scanning Auger electron microscopy, Raman depth profiling, and Raman mapping, as well as by use of elastic recoil detection analysis, grazing-incidence X-ray and electron backscatter diffraction, and grazing-incidence X-ray fluorescence analysis. The Cu(In,Ga)Se2 thin films used for the present comparison were produced during the same identical deposition run and exhibit thicknesses of about 2 µm. The analysis techniques were compared with respect to their spatial and depth resolutions, measuring speeds, availabilities, and detection limits.