Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (6027) (entfernen)
Sprache
- Englisch (3817)
- Deutsch (2165)
- Mehrsprachig (19)
- Russisch (7)
- Tschechisch (6)
- Französisch (6)
- Spanisch (2)
- Ungarisch (1)
- Italienisch (1)
- Portugiesisch (1)
Schlagworte
- Concrete (115)
- Simulation (90)
- Corrosion (78)
- Zerstörungsfreie Prüfung (58)
- Structural health monitoring (56)
- NDT (54)
- Monitoring (51)
- Reliability (48)
- Beton (46)
- Non-destructive testing (45)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (405)
- 7 Bauwerkssicherheit (293)
- 9 Komponentensicherheit (218)
- 3 Gefahrgutumschließungen; Energiespeicher (152)
- 8.4 Akustische und elektromagnetische Verfahren (96)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (87)
- 9.3 Schweißtechnische Fertigungsverfahren (87)
- 8.0 Abteilungsleitung und andere (84)
- 7.2 Ingenieurbau (82)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (80)
Paper des Monats
- ja (1)
We present a distributed polymer optical fiber sensor system for deformation monitoring of geotechnical infrastructure. The sensor system is based on the digital incoherent optical frequency domain reflectometry (I-OFDR) for the detection of local strain events along a perfluorinated polymer optical fiber (PF-POF) used as a sensing fiber. For the best possible load transfer, the PF-POFs were integrated onto geosynthetics which pose a sensor carrier for the sensing fiber. By using elastic PF-POF instead of a standard glass fiber as a sensing fiber the strain range of geosynthetics-integrated fiber optic sensors could be extended up to 10 % in accordance with the end-user requirements.
Die Einstufung von Hausmüllverbrennungsasche (IBA) als gefährlich oder nicht gefährlich nach der Gefahreneigenschaft HP14 (ökotoxisch) ist nach wie vor umstritten, da es noch keine keine allgemein anerkannten Methoden zur Bewertung gibt. Wenn die Berechnungsregeln angewendet werden sollen angewendet werden sollen, sind Kenntnisse über die chemische Zusammensetzung von IBA erforderlich. Informationen über über die chemische Zusammensetzung von IBA können mit einem Ansatz gewonnen werden, der auf der Gruppierung von Substanzen. Für IBA können vier Stoffgruppen definiert werden: 1. elementare und legierte Metalle, 2. leicht wasserlösliche Stoffe, 3. schwer lösliche Stoffe und 4. Stoffe mit starken chemischen Bindungen. Elementares und legiertes Cu und Zn sind in der IBA vorhanden und werden in der Regel als Nichteisenmetallfraktion zurückgewonnen, zumindest die größeren Partikel. Zn-Partikel, die kleiner als 1 mm sind, werden als H410 eingestuft, feine Partikel von Cu nur als H411. Die wasserlösliche Fraktion kann mit Standardauslaugungsmethoden quantifiziert werden Auslaugungsmethoden quantifiziert werden, z. B. bei einem Flüssigkeits-Feststoff-Verhältnis (L/S) von 2 oder 10 l/kg. Sowohl die Sulfate von Zn als auch von Cu gehören zu dieser Gruppe. In einer neueren Veröffentlichung wurde gezeigt, dass bei den oben genannten Metalle die ausgelaugte Menge weit unter dem Grenzwert von 1.000 mg/kg liegt, selbst wenn stöchiometrische Faktoren angewendet werden. Stoffgruppe 3 sind potenzielle H410-Stoffe. Dabei handelt es sich um Carbonate, Hydroxide und Oxide der betreffenden Elemente, die löslich sind in schwachen organischen Säuren wie Essigsäure löslich sind. Die Worst-Case-Stoffe der Gruppe 3, d. h. die Verbindungen mit den höchsten stöchiometrischen Faktoren, sind CuCO3xCu(OH)2 und ZnO. Stoffe mit starken chemischen Bindungen wie Silikate oder Sulfide sind nur löslich in starken Säuren (z.B. Königswasser) löslich und haben keinen Ökotoxizitäts-Gefahrencode. Das Mobilisierungsverhalten der relevanten Schwermetalle und damit der Gruppe der schwer schwerlöslichen Verbindungen kann mit der 4-stufigen sequentiellen Extraktion untersucht werden. Für die HP14 Einstufung könnte auch eine einstufige Extraktion ausreichend sein. Nur die Elemente Zn und Cu sind für die HP14-Einstufung der IBA von Bedeutung, da die Feststoffgehalte aller anderen Schwermetalle unterhalb des Feststoffgehalte aller anderen Schwermetalle unter der Cut-Off-Grenze von 0,1 % liegen, selbst wenn man sie in chemischen Verbindungen mit stöchiometrischen Faktoren. Im Ergebnis wurde gezeigt, dass IBA in der Regel als nicht gefährlich einzustufen ist.
Hydrogen pressure vessels are among the most essential components for reliable hydrogen technology. Under current regulations, a mostly conservative strategy is employed, restricting the usage time of hydrogen pressure vessels without providing information on the real remaining lifetime. During the service life, pressure vessels are inspected periodically. However, no established method that can provide continuous monitoring or information on the remaining safe service life of the vessel. In this paper, we propose a sensor network for Structural Health Monitoring (SHM) of hydrogen pressure vessels where data from all sensors are collected and centrally evaluated. Specifically, we integrate three different SHM sensing technologies namely Guided Wave ultrasonics (GW), Acoustic Emission testing (AT), and distributed Fiber Optic Sensing (FOS). This integrated approach offers significantly more information and could therefore enable a transition from costly and time-consuming periodic inspections to more efficient and modern predictive maintenance strategies, including Artificial Intelligence (AI)-based evaluation. This does not only have a positive effect on the operational costs but enhances safety through early identification of critical conditions in the overall system in real-time. We demonstrate an experimental set-up of a lifetime test where a Type IV Composite Overwrapped Pressure Vessel (COPV) is investigated under cyclic loading instrumented with AT, FOS, and GW methods. We acquired data from the sensor network until the pressure vessel failed due to material degradation. The data collected using the three different SHM sensor technologies is planned to be evaluated individually, using data fusion, and AI. In the future, we aim to integrate the measurement setup into a hydrogen refueling station with the data stream implemented into a digital signal processing chain and a digital twin.
Structural health monitoring of hydrogen pressure vessels using distributed fiber optic sensing
(2024)
We report on distributed fiber optic sensing-based monitoring of hydrogen composite overwrapped pressure vessels (COPV) to simultaneously increase the operational lifespan and mitigate maintenance costs. Our approach represents, to the best of our knowledge, the first application of distributed fiber optic sensing for COPV Type IV monitoring, where the sensing fibers are attached to the surface, rather than integrated into the composite material. Specifically, we attach an optical fiber of 50 m to the pressure vessel's surface, covering both the cylindrical and dome sections. We note that our fiber optic sensing technique relies on swept wavelength interferometry providing strain information along the entire length of the optical fiber with high spatial resolution even at the millimeter scale. When the vessel is pressurized, the sensing optical fiber shows a linear strain response to pressure at every position along the fiber. After thousands of load cycles, the vessel finally fails with the optical fiber detecting and precisely localizing the damage in the vessel’s blind dome area. Furthermore, we discuss the potential of state-of-the-art signal processing methods and machine learning for advancing predictive maintenance. This could reduce the number of regular inspections, mitigate premature maintenance costs, and simultaneously increase the vessel’s remaining safe service life. We believe that the structural health monitoring of hydrogen pressure vessels with fiber optic sensors can enhance trust in hydrogen technology contributing to the energy transition in the future.
Packages for the transport of spent nuclear fuel are designed to endure severe accidents. To obtain approval, these transport packages must adhere to the specification-based criteria of the international transport regulations SSR-6 of the International Atomic Energy Agency (IAEA). To ensure compliance with these requirements, specific mechanical and thermal tests need to be addressed with respect to the package type. Typically, SSR-6 prescribes a mechanical test followed by a thermal fire test as part of different testing scenarios. To approve the latter test of the sequence, BAM performs calorimeter tests in advance with so-called fire reference packages for characterizing the actual fire and its impact on the package to be tested. Packages are designed with different geometry sizes depending on their purpose. For previous tests, the implemented test setups in the fire test stand were sufficiently dimensioned and could cover all requirements in this respect. However, to cover additional testing needs in the future, BAM is expanding the test setup for the purpose of testing significantly larger packages.
In previous test setups one ring burner for propane surrounding the test specimen was sufficient. The limiting size in this configuration was the design height of the transport package to be tested. According to the thermal test of the IAEA-Regulations [1], a 30-minute fully engulfing 800°C pool fire or an equally severe fire, e.g., propane gas fire, must be applied to the transport package. Possible adjustments such as nozzle cross-section and propane mass flow can be adjusted to a certain extent. Further modifications, to cover significantly higher and larger packages all-around with a fully engulfing fire, must be accomplished with an additional, second burner ring. Both burner rings had the same dimensions and were mounted on top of each other at different heights to create a significantly larger volume of fire that completely engulfs the package including its impact limiter.
To meet the IAEA regulatory boundary conditions, the enhanced fire test stand with the second burner ring is tested with a large fire reference package and will then be used for real-size transport packages after all parameters are successfully met. This fire reference package represents the external geometry of a generic transport cask for radioactive material and is equipped with numerous temperature sensors to record temperature curves at the interior wall surfaces.
Um die Ausbreitungsmechanismen von Vegetationsbränden und besonders bei Bodenbränden besser zu verstehen, wurden die Einflussfaktoren auf die Brandausbreitung näher untersucht. Da die Brandausbreitung auch in starkem Maße von der lokalen Vegetation abhängt, war eine Charakterisierung der lokalen Vegetation und der Bodenverhältnisse wichtig. Die Wetterverhältnisse spielen einerseits im Vorfeld des Brandes durch längere Dürreperioden als auch während des Brandes, z.B. durch den Windeinfluss, zusätzlich eine große Rolle.
Durch die numerische Simulation kann eine größere Variation der Einflussgrößen abgebildet werden als durch die zeitlich und finanziell begrenzten experimentellen Möglichkeiten. Für die Berechnungen wird der Fire Dynamic Simulators (FDS) mit dem Paket WFDS verwendet. Dadurch kann mit einem vereinfachten 3-Phasen-Reaktionskinetikmodell, bestehend aus Dehydrierung, Pyrolyse, Kohleoxidation, die Ausbreitung von Vegetationsbränden verschiedener Waldbodenarten untersucht werden. Es wurden dazu 6 typische Pflanzenarten und Bodenproben aus Kiefern-, Buchen und Eichenbeständen ausgewählt.
Die gesammelten Waldbodenproben wurden alle hinsichtlich des Wassergehalts, des organischen Gehalts, der Packungsdichte, der Dichte und der statistisch ermittelten Pflanzenartenverteilung charakterisiert. Das kinetische Abbrandverhalten wurde durch Thermogravimetrische Analyse (TGA) untersucht. Alle diese Daten wurden als Eingabeparameter für die Simulation verwendet. Die numerischen Simulationen werden mit Experimenten im kleinen, mittleren und Real-Maßstab validiert.
Although intense wildfire research has been done in the US and in Australia, it cannot be transferred directly to the situation in Europe as the local vegetation has a significant influence on the fire spread. The EU-funded project TREEADS and the so-called German pilot within the project are concentrating on wildfire in Europe. Extensive experimental research is done on local vegeta-tion in Germany and the experimental results are used to adjust the Fire Dynam-ics Simulator (FDS) to local vegetation as a fuel in the calculations. The particle model and the boundary fuel model are developed for the simulation of forest fires. Both models require the kinetic input for the dehydration, pyrolysis, and char oxidation process. This three-step simplified model describes the basic fuel combustion kinetic. Most published simulations use the default kinetic input of pine needles from FDS user manual.
To adjust the simulation to local vegetation, the corresponding kinetic parame-ters have been experimental investigated. Samples of pine needles, moss and other falling leaves were collected, air dried and grinded into powder. The TG analysis of all these samples were done under different heating rate of 5, 10 and 20K/min.
The activation energy and the corresponding pre-exponential factor were calcu-lated. The results show that fire spread depends significantly on the vegetation and comparison with small scale experiments show good agreement using the new kinetic parameters. The new model is applied to a larger scenario and will be compared to the results of large-scale experiments for further validation of the model.
Heavy-weight packages for the safe transport of radioactive material are equippedwith impact limiters often built ofwood-filled steel sheet structures to fulfil the requirements of the International Atomic Energy Agency (IAEA) regulations. The requirements definemechanical tests followed by a thermal test, including criteria ensuring the package design’s ability to withstand severe accidents and provide a high level of technical safety.
Impact limiters are a package component mainly designed for the packages to withstand severe mechanical accident scenarios. In drop tests the impact limiters absorb the kinetic energy during impact of the package. The package must then - with its pre-damaged impact limiters - endure a thermal test defined precisely in the IAEA regulations as a 30-min fully engulfing 800 °C-fire. After the fire, a wood-filled impact limiter may continue to release thermal energy from an ongoing combustion process, defining relevant package temperatures. The energy flow from a possible burning impact limiter to the package is important for the safety evaluation of transport packages. To investigate the combustion behaviour of densely packed layers of spruce wood, encapsulated in pre-damaged cylindrical metal enclosures, a test set-up has been realised. The set-up consists of a combustion chamber to perform these tests under defined boundary conditions. The temperature development of the test specimens will be observed fromoutside with a thermographic imager, with HD-Cameras, and the mass loss will be measured during the entire test. Airflow conditions in the combustion chamber are analysed using Computational Fluid Dynamics (CFD) calculations in OpenFOAM. The planned combustion test setup is described.
A monitoring and surveillance system is a mandatory element to ensure that a radioactive waste disposal facility provides and meets the required level of safety during both its operational and closure periods. In this study an innovative approach for the identification and monitoring of the structural integrity of stored radioactive drums is presented. The activities were carried out in the context of the European Project PREDIS, whose goal is the development of a robust and reliable sensing technology for monitoring and long-term storage of radioactive waste packaging systems.
Specifically, the focus was set on the development of innovative and smart sensor technologies, non-destructive examination tools, and/or devices capable to improve the safety of the storage by minimizing the number of interventions of cemented waste packages. Both conventional and innovative techniques, such as muon-tomography, SiLiF neutron and SciFi gamma detection, or contactless and smart radio transceiver technology provided with radiation monitoring sensors, have been considered and adapted for the use under repository conditions. Indeed, gamma and neutron detection techniques exploit the radiological information coming from inside the drums, while imaging techniques proved to be effective in spotting high density objects embedded inside the concrete: together, they allow to improve safety and security and can provide an early alert on behavioral changes hinting at anomalies in the drums.
Indirect combustion noise due to the interaction of flow inhomogeneities with a choked combustion-chamber exit is an important cause of combustion instability in solid rocket motors.
Moreover, it is believed to be an issue in electrical-power generation turbines and aero-engines. If these flow inhomogeneities are essentially characterized by the fluid having a locally appreciablydifferent thermodynamic state, the acoustic response engendered by its interaction with the combustion-chamber exit is commonly referred to as entropy noise. In this paper, dedicated numerical-simulation results of entropy-patch choked-nozzle interactions are presented. Two types of entropy patches were considered: rectangular slugs and circular spots. Moreover, analytical-model-based analysis, of said simulation results, is presented. Based on said analysis, the authors posit the existence of three modeling regimes: the quasi-steady-modeling regime, the blended-physical-effects regime, and the inertial-modeling regime.