Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (6018) (entfernen)
Sprache
- Englisch (3808)
- Deutsch (2165)
- Mehrsprachig (19)
- Russisch (7)
- Tschechisch (6)
- Französisch (6)
- Spanisch (2)
- Ungarisch (1)
- Italienisch (1)
- Portugiesisch (1)
Schlagworte
- Concrete (114)
- Simulation (90)
- Corrosion (78)
- Zerstörungsfreie Prüfung (58)
- Structural health monitoring (56)
- NDT (54)
- Monitoring (51)
- Reliability (48)
- Beton (46)
- Non-destructive testing (44)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (397)
- 7 Bauwerkssicherheit (291)
- 9 Komponentensicherheit (218)
- 3 Gefahrgutumschließungen; Energiespeicher (149)
- 8.4 Akustische und elektromagnetische Verfahren (96)
- 9.3 Schweißtechnische Fertigungsverfahren (87)
- 8.0 Abteilungsleitung und andere (84)
- 7.2 Ingenieurbau (82)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (82)
- 4 Material und Umwelt (79)
Paper des Monats
- ja (1)
Die Transformation der Energienutzung von konventionellen zu erneuerbaren Quellen führt dazu, dass zukünftig mehr Energie effizient zwischengespeichert werden muss. Eine Möglichkeit der elektrochemischen Zwischenspeicherung bieten Lithium-Ionen-Batterien. Hierfür können ausgemusterte Automobilantriebsbatterien verwendet werden. Erfüllen sie die hohen Anforderungen des mobilen Bereichs nicht mehr, haben sie oftmals noch eine ausreichende Kapazität und Leistungsfähigkeit für die stationäre Zwischenspeicherung.
Neben der Verwendung der Batterien im größeren Maßstab, z.B. bei Energieversorgern, werden durch den vermehrten Einsatz von Photovoltaik-Anlagen in Ein- und Mehrfamilienhäusern verstärkt Zwischenspeicher für Privathaushalte nachgefragt. Dies birgt auch für Einsatzkräfte neue Herausforderungen in der Gefahrenabwehr.
Im vom Bundesministerium für Bildung und Forschung (BMBF) geförderten Verbundprojekt „SEE-2L – Sicherheit elektrochemischer Energiespeicher in Second Life Anwendungen“ wurden Versuche mit Second Life Modulen durchgeführt. Verbundpartner im Projekt waren neben der vfdb die Otto-von-Guericke-Universität Magdeburg und die Bundesanstalt für Materialforschung und -prüfung. Zudem war das Institut der Feuerwehr Nordrhein-Westfalen eingebunden.
Die durchgeführten Versuche bilden eine Grundlage für die Einordnung der Batteriespeicher, z.B. aus Sicht des baulichen Brandschutzes, zur Methodik der Brandbekämpfung oder zur Risikobewertung hinsichtlich der Prozess- und Anlagensicherheit.
Im Beitrag werden die Versuchsergebnisse vorgestellt und Ansätze für deren Anwendung gezeigt. Um die gewonnenen Erkenntnisse zu vermitteln, wurde im Projekt zudem ein Schulungskonzept für Einsätze mit Lithium-Ionen-Technologien erarbeitet, das im Beitrag präsentiert wird. Es besteht aus theoretischen und praktischen Anteilen, sodass bei den Feuerwehren praxisnah aus- bzw. fortgebildet werden kann.
Germany had been transporting spent fuel to the reprocessing plant in Sellafield and La Hague for decades until around 2005. Resulting from the obligation to take back the vitrified high-level waste from reprocessing six CASTOR® HAW28M filled with 168 canisters with radioactive waste in vitrified form were transported from Sellafield to the interim storage facility Biblis in 2020. Rail wagons were used for the transport to the port in Barrow-in-Furness, where they were loaded into a dedicated seagoing vessel, certified as INF Class 3 according to the INF Code. This was the first time that vitrified high level waste with considerable heat load was transported under a German design approval certificate.
BAM was involved in the authority assessment of the conditions for the sea transport. For the first transport BAM required among others, assessment of temperature distribution during transport, logging of temperatures of cargo bays and graphical imaging of temperatures of the bay with the cask in order to ensure compliance with temperature specifications, e.g. maximal neutron absorber and gasket temperatures. Special interest was taken in the identification of possible events exceeding the specified temperatures considering the different philosophies of IMDG code and its supplement INF code regarding temperature control of hatches. Results show compliance with assumed conditions.
Normung und Standardisierung in der zerstörungsfreien Prüfung finden auf nationaler, europäischer und internationaler Ebene statt. Die Übernahme von Leitungsfunktionen in diesen Gremien erzeugt die Möglichkeit der Steuerung von Themen und Inhalten der relevanten Normen. Das persönliche Engagement der Fachexpert*innen in den nationalen Gremien und den europäischen und internationalen Arbeitsgruppen ist ein zusätzlicher Faktor für die inhaltliche Korrektheit und die inhaltliche Ausrichtung der Norm. Denn wer nicht normt, wird genormt und muss letztlich Normen anwenden, die andere entsprechend ihrer eigenen Interessen gestaltet haben. Voraussetzung für die Teilnahme in europäischen und internationalen Normungsgremien ist die Mitwirkung in den entsprechenden DINSpiegelgremien, welche die europäischen (CEN) und internationalen (ISO) Aktivitäten spiegeln und die Fachexpert*innen für die Mitarbeit autorisieren.
Auf internationaler Ebene findet die Normungsarbeit in den technischen Komitees ISO/TC 135 “Non-destructive testing” und ISO/TC 44/SC 5 “Testing and inspection of welds” und ihren Arbeitsgruppen statt. Das europäische Pendant ist das CEN/TC 138 “Zerstörungsfreie Prüfverfahren” mit seinen Arbeitsgremien. Die DINSpiegelgremien sind für die deutsche Mitarbeit in diesen Gremien und die inhaltliche Bewertung der Norm-Entwürfe zuständig.
Bei der zerstörungsfreien Prüfung verlegter Eisenbahnschienen werden die Rohdaten derzeit in proprietären Datenformaten gespeichert und auf Datenträgern zwischen den Prüfzügen und den auswertenden Stellen versendet. Die proprietären Datenformate sind in der Regel nur den Herstellern der Prüfsysteme bekannt und deren Dokumentation nicht allgemein zugänglich.
Die „Standard Practice for Digital Imaging and Communication in Nondestructive Evaluation“ (DICONDE), basierend auf dem medizinischen Standard „Digital Imaging and Communication in Medicine“ (DICOM), ermöglicht es, sowohl Prüfdaten als auch Prüfergebnisse und Streckeninformationen in einem standardisierten Format zu speichern und zwischen verschiedenen Endpunkten zu übertragen.
Das Poster gibt zunächst einen kurzen Überblick über die hierarchische Struktur von DICONDE und zeigt dann, wie DICONDE bei der Prüfung verlegter Eisenbahnschienen verwendet werden kann. Die geometrischen Besonderheiten (mehrere Kilometer Länge pro Prüffahrt, kurviger Streckenverlauf) stellen dabei eine besondere Herausforderung dar. Im Rahmen des mFUND-geförderten Projektes „Arteficial Intelligence for Railway Inspection (AIFRI)“, Förderkennzeichen 19FS2014C, wurde ein Vorschlag für eine Erweiterung des DICONDE-Standards für die Schienenprüfung erarbeitet und bei der ASTM eingereicht.
Since 2016 ISO Technical Committee (TC) 265 is working on standardization the whole CCS-process chain. Around 30 countries are working together to provide international guidelines. As ISO 27913 was the first standard finished within these activities it is already in the stage of first revision.
The objective of ISO 27913 is “to provide specific requirements and recommendations on certain aspects of safe and reliable design, construction and operation of pipelines intended for the large-scale transportation of CO2 that are not already covered in existing pipeline standards such as ISO 13623, ASME B31.8, EN 1594, AS 2885 or other standards. Existing pipeline standards cover many of the issues related to the design and construction of CO2 pipelines; however, there are some CO2 specific issues that are not adequately covered in these standards. The purpose of this document is to cover these issues consistently. Hence, this document is not a standalone standard, but is written to be a supplement to other existing pipeline standards for natural gas or liquids for both onshore and offshore pipelines.”
This contribution shall provide information on the content, the current stage of the revision process, encourage to contribute to this standard and make listeners aware to consider the influence of ISO standard on documents currently in draft.
The structural integrity of outer reinforced concrete (RC) containments of nuclear power plants provides an essential shield against external hazards. If this containment is damaged by an impact event, such as an aircraft crash, the question arises to which degree the reinforced concrete containment still has its protective capability. This concerns both purely structural protection and protection against liquids penetrating the interior of the containment. Due to the dimensions of the containment structures, it is difficult to perform real scale impact experiments, so in the past decades plate geometries at medium scale have been used for investigations. Detailed investigations on the structural behaviour of RC members or RC plates subjected to impact loading have already been presented in Just et al., Hering, Hering et al., Bracklow et al., Hille et al. and Nerger et al.
The following investigations deal with the single and multiple impact event (first hard impact and/or subsequent soft impact) on a RC specimen, which provides the basis for further investigations. A description of the test setup and the test procedure as well as a presentation of the test results from the impact tests are provided.
Furthermore, the experimental program is presented, which the damaged RC specimens are to undergo to deal with the question of how much the impact-damaged RC structure has become permeable to liquid media, such as water and kerosene, depending on the intensity of the impact. The aim of these following investigations is to develop a test setup that can be applied to investigate the liquid penetration behaviour (LPB) of small, medium, and large-scale RC members.
In addition to the liquid penetration experiments, the damaged specimens are to be examined by planar tomography to obtain the damage inside the specimen. The combination of damaging event, fluid penetration behaviour and tomography should enable a comprehensive understanding of the damage to the RC specimen.
Mit der Abkehr von der Nutzung fossiler Rohstoffe rücken regenerative Energieträger immer weiter in den Focus. Neben klassischen Holzkohlen werden verstärkt so genannte Biokohlen produziert. Dieser Begriff findet Verwendung für mit Hilfe verschiedener Verfahren karbonisierte pflanzliche, tierische oder mikrobielle Ausgangsstoffe. Diese Kohlen werden zum Teil über weite Strecken zum Bestimmungsort transportiert (Überseetransporte) oder vor Verwendung für längere Zeit gelagert.
Häufig zeigen diese Kohlen ein kritisches Selbstentzündungsverhalten, wobei Einstufungstests (UN N.4 Test) versagen können. Ein negatives Testergebnis des UN N.4 Tests führte dabei in der Vergangenheit zur Nichteinstufung als selbsterhitzungsfähiger Stoff; in der Praxis entzündeten sich aber bereits vergleichsweise kleine Schüttungen (einige m³), z. B. beim Seetransport in Containern. Der Artikel geht auf dieses Problem ein und stellt Prüfverfahren vor. Aus den Ergebnissen durchgeführter Untersuchungen werden Empfehlungen für sicheren Transport und Lagerung abgeleitet.
In einer Versuchsreihe im Realmaßstab wurden drei Flüssigwasserstofftanks (LH2) unterfeuert. Hierbei sollte unter anderem geklärt werden, ob es, analog zu druckverflüssigten Gasen, zu einem BLEVE (Boiling Liquid Expanding Vapor Cloud Explosion) kommen kann. Die Experimente wurden auf dem Testareal Wasserstoffsicherheit des Testgeländes Technische Sicherheit der Bundesanstalt für Materialforschung und -prüfung (BAM-TTS) im Rahmen einer Forschungskooperation zwischen der BAM und Gexcon, als Teil des SH2IFT-Programms durchgeführt. Es handelte sich um doppelwandige, vakuumisolierte Tanks von 1 m³ Volumen. Die zylindrischen Tanks unterschieden sich durch ihre Ausrichtung (horizontal oder vertikal) und das verwendete Isoliermaterial (Perlit oder Mehrschichtisolierung (MLI). Der Füllgrad der Tanks betrug bei jedem der durchgeführten Tests etwa 35-40 %. Die Brandlast wurde homogen durch ein propangasbetriebenes Brennersystem erzeugt. Gemessen wurden die Bedingungen im Behälter (Temperaturen und Druck) sowie äußere Randbedingungen und Auswirkungen beim Versagen (Wärmestrahlung, Druckwellen, Flammenballentwicklung und Fragmentierung). Mit Bolometern wurde die Wärmestrahlung gemessen, die sowohl durch das Propanfeuer als auch durch einen möglichen Feuerball/BLEVE erzeugt wurde. Zur Messung der durch das Bersten von Behältern/BLEVEs erzeugten Druckwellen wurden sog. Pencil-Probes verwendet. Des Weiteren wurden mehrere Kameras zur Überwachung der Experimente eingesetzt: Normalbildkameras, Infrarot (IR)-Kameras und Hochgeschwindigkeitskameras, sowohl bodengestützt als auch mittels einer Drohne. Zwei der untersuchten Tanks, ein horizontaler und der vertikale, die beide mit Perlit isoliert waren, hielten der Brandbelastung stand, ohne dass es zu einem Behälterversagen kam. Der mit MLI isolierte horizontale Behälter barst nach 1 Stunde und 6 Minuten und erzeugte dabei einen Feuerball, Trümmerflug und eine Druckwelle. Neben der Beschreibung der Auswirkungen eines kritischen Versagens eines LH2-Tanks sind weitere Ziele der Arbeit die Identifizierung kritischer Behälterzustände sowie die Erstellung eines umfassendes Datensatzes der Trümmer des geborstenen Tanks. Die größten Abstände für kritische Abstände ergaben sich durch Fragmentwurf. Hier sollen 3D-Scans für die Verwendung in CAD und FEM Anwendungen bereitgestellt werden. Umfassende Daten zu den Fragmentwurfweiten, -massen und -positionen wurden bereits publiziert. Damit soll die Voraussetzung geschaffen werden, um vorhandene Wurfweitenmodelle, die bisher nur für einschalige Behälter konzipiert wurden auf ihre Eignung für mehrschalige Behälter zu überprüfen oder mögliche Anpassungen anhand der realen Daten vornehmen zu können.
Zudem wurde damit begonnen die nicht geborstenen Tanks zu vermessen und zu zerlegen, um u.a. die Perlit-Schüttung auf Beeinträchtigungen durch den Transport und die Unterfeuerung zu untersuchen.
In einer Reihe von Experimenten wurden die möglichen Folgen der Freisetzung von verflüssigtem Wasserstoff (LH2) auf, bzw. unter Wasser untersucht. Die Experimente zielten darauf ab, eine unbeabsichtigte Freisetzung von LH2 (z.B. durch Schlauchabriss) insbesondere bei der Betankung eines Schiffes zu simulieren. Für verflüssigtes Erdgas (LNG) wurden dabei sog. RPT’s (rapid phase transition) nachgewiesen, bei denen die spontane Verdampfung relevante Druckwellen erzeugt. Es kann nicht ausgeschlossen werden, dass RPTs auch im Falle von LH2 möglich sind. Die Versuche wurden auf dem Testareal Wasserstoffsicherheit auf dem Testgelände Technische Sicherheit der Bundesanstalt für Materialforschung und -prüfung (BAM-TTS) in Horstwalde, im Rahmen einer Forschungskooperation zwischen der BAM und Gexcon im Rahmen des SH2IFT-Programms durchgeführt. Die LH2-Freisetzungen erfolgten direkt aus einem LH2-Tanklastwagen über eine lange, flexible, vakuumisolierte Transferleitung. Während die Freisetzung oberhalb und unterhalb der Wasseroberfläche jeweils vertikal orientiert war, wurde bei der Unterwasserfreisetzung zusätzlich eine horizontale Ausströmung, parallel zur Wasseroberfläche realisiert. Zur Bestimmung des Massenstromes, wurde ein Wägesystem unter dem Tankwagen eingesetzt. Spezielle Drucksensoren wurden verwendet, um die durch die Freisetzungsvorgänge erzeugten Stoßwellen sowohl im Wasser als auch in der Luft zu messen. Die Gaskonzentrationen über dem Wasserbecken wurden an verschiedenen Positionen gemessen. Hochgeschwindigkeits-, Infrarot- (IR) und normale Kameras wurden eingesetzt, um die Phänomenologie der Freisetzung aufzuzeichnen und das Verhalten der Gaswolke im Zeitverlauf zu verfolgen. Neben den fest installierten Systemen an Land, kamen auch Unterwasserkameras sowie eine Drohne mit Normal- und IR-Kameras zum Einsatz.
Zwei Wetterstationen wurden zur Messung von Windgeschwindigkeit, Windrichtung, Temperatur und Luftfeuchtigkeit während aller durchgeführten Tests eingesetzt. Des Weiteren kamen Bolometer zur Wärmestrahlungsmessung zum Einsatz. Zwar führten die Freisetzung zu einer hochturbulenten LH2/Wasser Mischzone, jedoch zu keinen nennenswerten Überdrücken durch RPT. Im Gegensatz dazu wurde unerwartet, aber reproduzierbar, eine Zündung der Gaswolke in freier Luft in einiger Entfernung von den Instrumenten und dem Ort der Freisetzung beobachtet. Die daraus resultierenden Gaswolkenexplosionen führten zu relevanten Überdrücken und zur Wärmeabstrahlung in die Umgebung.
Portland cement is one of the principal sources of anthropomorphic CO2 emissions. It is estimated that cement production contributes up to 10% of greenhouse gas emissions and annual cement production over 4 billion tons. This has led to the development of a range of alkali activated materials (AAM), the most common precursor materials being class F fly ash and blast furnace slag. At present Class C Fly Ash is not widely utilized as an AAM due to the chemical composition and activation requirements. However, initial research on high Calcium German Class C Fly Ash suggests that the material may have potential for application as an AAM. This paper reports the development of ambient cured alkali activated mortar optimised by varying the alkali modulus and w/b ratio. The evolution of the mechanical and microstructural properties is reported over the initial 28 day period. Compressive strength in excess of 10 MPa at 7 days and 15 MPa at 28 days was achieved at ambient temperature. Similar strengths were observed for both 10% and 15% dosage but as dosage increases the optimal Alkali Modulus reduces.