Glow discharge optical emission spectroscopy (GD-OES) is a technique for the analysis of solids such as metals, semiconductors, and ceramics. A low-pressure glow discharge plasma is applied in this system, which ‘sputters’ and promotes the sample atoms to a higher energy state. When the atoms return to their ground state, they emit light with characteristic wavelengths, which a spectrometer can detect. Thus, GD-OES combines the advantages of ICP-OES with solid sampling techniques, which enables it to determine the bulk elemental composition and depth profiles. However, direct solid sampling methods such as glow-discharge spectroscopy require reference materials for calibration due to the strong matrix effect.
Reference materials are essential when the accuracy and reliability of measurement results need to be guaranteed to generate confidence in the analysis. These materials are frequently used to determine measurement uncertainty, validate methods, suitability testing, and quality assurance. In addition, they guarantee that measurement results can be compared to recognized reference values. Unfortunately, the availability of certified reference materials suited to calibrate all elements in different matrix materials is limited. Therefore various calibration strategies and the preparation of traceable matrix-matched calibration standards will be discussed.
Machine learning is an essential component of the growing field of data science. Through statistical methods, algorithms are trained to make classifications or predictions, uncovering key insights within data mining projects. Therefore, it was tried in our work to combine GD-OES with machine learning strategies to establish a new and robust calibration model, which can be used to identify the elemental composition and concentration of metals from a single spectrum. For this purpose, copper reference materials from different manufacturers, which contain various impurity elements, were investigated using GD-OES. The obtained spectra information are evaluated with different algorithms (e.g., gradient boosting and artificial neural networks), and the results are compared and discussed in detail.
The calibration of isotope ratio measurements is an ongoing challenge since instrumental isotope fractionation (IIF) has been detected in mass spectrometry (MS). There is a variety of approaches which either bypass IIF such as delta measurements or refer to reference materials (RMs) and thus shifting the problem of calibration to somebody else: the RM producer. For certifying isotope RMs with absolute isotope ratios only a few approaches are available, namely the isotope mixture approach, the double spike approach, the mass bias regression model and total evaporation in TIMS. All of them require either enriched isotopes, isotope RMs of another element or an RM for correcting residual error. As the enriched isotopes required for the isotope mixture and the double spike approach need to be fully characterized beforehand, all mentioned calibration approaches require a standard.
Here, a new and standard-free calibration approach for obtaining absolute isotope ratios of multi-isotopic elements has been developed. The underlying principle is that each MS suffers from IIF and thus yields a specific isotope fractionation line in a three-isotope diagram. When applying a second MS featuring a different ionization mechanism, we obtain a second isotope fractionation line with a different slope in the same three-isotope diagram. In both cases the absolute isotope ratios range somewhere on the isotope fractionation line. Consequentially, the intersect of both lines yield the absolute isotope ratios of the measured sample. This theory has been tested by measuring Cd and Pb isotope ratios of suitable isotope RMs with a TIMS and an ICP-MS, both equipped with multi-collector array. During the measurements the ionization conditions were changed such that different extent of the isotope fractionation has been achieved. With the resulting data set the theory described above could be verified. The obtained absolute isotope ratios were metrologically compatible with the certified isotope ratios. The remaining average bias of -5 ‰ can be reduced with further improvements. The calibration approach is universal and can be applied to any multi-isotopic element and it is not limited by the type of the mass spectrometer.
Sensors for assessment of the structure’s behaviour must work durably and reliably. Even if the performance of produced and delivered sensor is well specified, the sensor's strain characteristics and the performance of an applied sensor can significantly differ from the virgin sensor’s performance. The quality and appropriateness of installation decides over the long-term operability and getting reliable measurement results. The paper shows how important a clear terminology is, which problems might occur when sensor are not well characterized according to Standards or guidelines. Short outlook to experimental methods providing clear knowledge and appropriate Validation of the sensor’s performance for a defined measurement task is given. Finally, the state of-the-art in fibre-optic sensor Standardization is given.
The characterization of the optical properties of photoluminescent systems, that scatter, like dispersions of nanoparticles with sizes exceeding about 25 nm or solid nanophosphors is of increasing importance for many applications in the life and material sciences. Examples present nanoscale optical reporters and dye-doped microparticles for bioimaging, fluorescence assays or DNA sequencing as well as nanocrystalline emitters like semiconductor quantum dots and rods or lanthanide-based nanophosphors embedded into solid matrices for solid state lighting, display technologies, or barcoding/security applications. The assessment and comparison of material performance as well as the development of rational design strategies for improved systems require spectroscopic tools, which enable the determination of the signal-relevant optical properties like photoluminescence quantum yields and brightness values.
This encouraged us to built up an integrating sphere setup enabling absolute measurements of photoluminescence spectra and quantum yields of transparent and scattering photoluminescent dispersions and solid samples in different measurement geometries, i.e., direct and indirect illumination and the combination of both geometries and perform first measurements with selected emitters. Here, the design of this setup is presented and first recommendations concerning suitable measurement geometries are given.
The far infrared refractive indices and the extinction coefficients of liquids can be obtained by means of spectroscopic ellipsometry in attenuated total reflection configuration. Such optical constants will contribute to a spectroscopic data base in the far infrared and terahertz spectral regions. The experimental implementation and the calibration procedure of the method are described in detail. The temperature dependency of the optical constants for water over a broad spectral range is exemplarily presented.
Direct current (DC) fast flow glow discharge mass spectrometry is an important and versatile tool for multielemental trace analysis of conductive solid materials down to the µg/kg level. Special benefits are minimum demands on sample preparation, avoiding losses and contamination, and only short analysis time.
For fast flow GD sources, the quantification strategy based on relative standard sensitivity factors (Standard RSFs) which are independent of matrix is not sufficiently satisfying regarding accuracy for each matrix and element [1]. Therefore matrix-matched calibration samples (MMCS) are required to achieve reliable quantification. In fact, the list of existing certified reference materials (CRM) appropri-ate for calibration in trace analysis is rather short.
Convenient synthesis of homogeneous MMCS, as e.g. easily obtained in liquid sampling spectrometry, can facilitate the application of fast flow GD-MS for quantification of impurities in a variety of matrices.
Pressing of metal powders for the preparation of MMCS for GD-MS was suggested earlier [2], the method was further modified by use of analyte solutions for doping of rather pure metal powders such as Cu and Zn [3], but has not yet been applied Ni matrix.
In the present work we describe the determination of matrix-dependent relative sensitivity factors (RSFs) for Mg, Al, Cr, Mn, Fe, Co, Cu, Zn, Ag, Cd, Tl, Pb and Bi in pure Ni by using the liquid doping approach for the preparation of synthetic pressed Ni-powder samples. A four point-calibration was used applying the fast flow glow discharge mass spectrometer, Element GD (Thermo Fisher). The determined RSF were verified against suitable CRM and compared with the standard RSF given by the supplier of the instrument.
The obtained results demonstrate a satisfying Agreement with the certified values of the CRM and a significant improvement for the quantification of most of the determined elements in comparison with standard RSF.