Results from different methods applied to micro- and nanoplastics (MNPs) analysis show that there are large gaps in harmonisation with respect to terminology, size classes, sample preparation protocols and, finally, to the comparability of the measurands and descriptors.
Within the European research cluster to understand the health impacts of micro- and nanoplastics (CUSP) working group WG3-Inter-Laboratory Comparisons an overview of the existing detection methods revealing advantages and disadvantages regarding the analytical tasks is being compiled. There is a clear need to develop high class characterized reference materials for MNPs in the size ranges of 100-10 µm and smaller than 10 µm, so that these can be used to validate methods and to make results comparable. Inter-laboratory comparisons (ILCs) on model samples with complex matrices regarding mass, or water samples for number-based methods, will help us to advance the process of harmonization as well as to train users early in process of developing new methods.
We plan to keep all five CUSP projects well-connected also with the 'outside' MNP projects and ILCs and to extract the optimum of needs, capabilities, and efforts in order to launch new VAMAS ILCs which should expand already available ones.
In this breakout session first, an introduction is given on the planning and organisation of an inter-laboratory comparison (ILC) under the pre-standardisation plattform VAMAS within the newly formed technical working area TWA 45 Micro and Nano Plastics in the Environment. An update with the ILCs on micro- and nanoplastic performed so far is also given. In the third part, the requirements for a reference materials are presented. The needs from the different H2020 micro- and nanoplastic projects are collected and compiled in an ILC matrix for joint activities as the next steps.
In this contribution, two large-area EDS detectors were tested according to the procedure proposed by Procop et al. (2015). In a first step, the optimal working distance (WD) in the two different SEM chambers was determined by moving the sample stage in the Z direction and monitoring the count rates at a magnification of 10,000 and a field of view of 25.6 µm. The WD at which the highest intensity was measured was selected as the optimal position, corresponding to the crossover between the EDS detector optical axis and electron beam optical axis. Next the Cu Kα peak was measured at different relative EDS positions while it was partially removed from the fully inserted position. The spectrum at each location was collected for 10 sec using the highest pulse rate and intermediate current to minimize pile up effects. The ‘inverse squared normalized intensities vs. relative EDS position’ used to extract the true detector – specimen distance shows a non-linear relationship even at the minimal relative positions, which indicates shadowing due to obstruction or use of an unsuitable and/or off-centered collimator. The normalized count rates measured as a function of the EDS distances, results in a too low GCE (too low true solid angles) for both tested detectors. The source of losses of signal was shadowing caused by collimators.
The progress in the VAMAS Project #15" Measurement of particle size and shape distribution of bipyramidal titania including deposition from liquid suspension" within TWA 34 Nanoparticle Populations is presented with highlight of the following points:
- Determine and compare particle size and shape distribution by means of:
• electron microscopy (SEM, TEM, STEM-in-SEM)
• atomic force microscopy (AFM)
• small angle X-ray scattering (SAXS)
- Determine uncertainty induced by deposition protocol from liquid suspension with comparison to known values from a prior ILC with already deposited nanoparticles on TEM grids.
- Provide comparative validation of protocols for the techniques other than TEM.
The progress of the VAMAS Project 16 "Measurement of (relative) number concentration of bimodal silica nanoparticles including deposition from liquid suspension" in TWA 34 Nanoparticle Populations is presented. Follwowing points are discusssed:
- Validate the performance of imaging methods to measure the relative number concentration
• electron microscopy (SEM, TEM) and atomic force microscopy (AFM)
• two modes of bimodal (30 and 60 nm) silica nanoparticles
- Validate the performance of small angle X-ray scattering (SAXS) for the traceable measurement of the number concentration of the two modes.