Femtosecond vs. Nanosecond Laser-induced XUV Spectroscopy (LIXS)
- In contrast to laser-induced breakdown spectroscopy (LIBS), measuring after a delay as long as a few microseconds, laser-induced XUV spectroscopy (LIXS) takes advantage of emissions from the very first instant of the pristine plasma. This process exhibits stable and intense line and recombination emissions in the XUV-range. Therefore, common challenges for precise measurements (e.g. quantification efforts) in LIBS caused by signal intensity fluctuations due to matrix effects and plasma-flicker noise are improved, as shown for ns-pulses.
A femtosecond laser (pulse length ~100 fs) interacts fundamentally different with matter than a nanosecond laser. Of the many photons needed for ionization of the sample, less are absorbed via inverse Bremsstrahlung and more in a Franck-Condon multiphoton absorption (MPA) process. In combination with the higher peak power, and therefore higher initial plasma temperature (> 10 eV), atoms are selectively ionized to a higher degree while at the same timeIn contrast to laser-induced breakdown spectroscopy (LIBS), measuring after a delay as long as a few microseconds, laser-induced XUV spectroscopy (LIXS) takes advantage of emissions from the very first instant of the pristine plasma. This process exhibits stable and intense line and recombination emissions in the XUV-range. Therefore, common challenges for precise measurements (e.g. quantification efforts) in LIBS caused by signal intensity fluctuations due to matrix effects and plasma-flicker noise are improved, as shown for ns-pulses.
A femtosecond laser (pulse length ~100 fs) interacts fundamentally different with matter than a nanosecond laser. Of the many photons needed for ionization of the sample, less are absorbed via inverse Bremsstrahlung and more in a Franck-Condon multiphoton absorption (MPA) process. In combination with the higher peak power, and therefore higher initial plasma temperature (> 10 eV), atoms are selectively ionized to a higher degree while at the same time thermal dissipation and equilibration is reduced. This specificity in excitation leads to a reduced background and the highly ionized atoms overwhelmingly emit the desired XUV-radiation. Thus, fs-LIXS promises to lead to “cleaner” spectra with sharper separation of the emission lines.
The capabilities of a fs-LIXS setup in comparison to ns-LIXS will be discussed. Samples of pure elements (Al, Si, Ni, Fe, Mg), as well as composite samples (CaF, LiF, PTFE, polypropylene) serve as model systems to demonstrate these capabilities.…


| Autor*innen: | Simon Blume |
|---|---|
| Koautor*innen: | Dávid Jenö Palasti, Davide Bleiner, Jens Riedel |
| Dokumenttyp: | Vortrag |
| Veröffentlichungsform: | Präsentation |
| Sprache: | Englisch |
| Jahr der Erstveröffentlichung: | 2026 |
| Organisationseinheit der BAM: | 1 Analytische Chemie; Referenzmaterialien |
| 1 Analytische Chemie; Referenzmaterialien / 1.3 Instrumentelle Analytik | |
| DDC-Klassifikation: | Naturwissenschaften und Mathematik / Chemie / Analytische Chemie |
| Freie Schlagwörter: | Elemental analysis; Femtosecond; LIXS; XUV |
| Themenfelder/Aktivitätsfelder der BAM: | Chemie und Prozesstechnik |
| Chemie und Prozesstechnik / Chemische Charakterisierung und Spurenanalytik | |
| Veranstaltung: | EMSLIBS 2025 |
| Veranstaltungsort: | Senlis, France |
| Beginndatum der Veranstaltung: | 26.01.2026 |
| Enddatum der Veranstaltung: | 30.01.2026 |
| Verfügbarkeit des Dokuments: | Datei im Netzwerk der BAM verfügbar ("Closed Access") |
| Datum der Freischaltung: | 06.02.2026 |
| Referierte Publikation: | Nein |
| Eingeladener Vortrag (wissenschaftliche Konferenzen): | Nein |