Tracing overdischarge-induced degradation in lithium-ion cells using cyclic voltammetry and differential voltage analysis
- Differential voltage analysis (DVA) and cyclic voltammetry (CV) are powerful
electroanalytical techniques. While CV can be used to study the kinetics of electron transfer reactions [1], DVA can visualise phase transitions by correlating the opencircuit voltage and exchanged charge [2]. Recently, DVA receives an increasing attention in the battery community for characterising full-cell setups. In contrast, CV is less prominent for batteries, yet the prevalently used technique for ex-situ characterisations of novel electrode materials in half-cell configuration.
In this study, we have investigated the overdischarge process of LiFePO4 pouch cells – which is usually presumed to result in a decomposition of the solid electrolyte interphase (SEI) and a corrosion of the copper current collector – in a complementary electrochemical analysis which uses both, CV and DVA in full-cell mode. For this purpose, CV consisting of three low sweep-rate scans and DVA of three low current rate cyclesDifferential voltage analysis (DVA) and cyclic voltammetry (CV) are powerful
electroanalytical techniques. While CV can be used to study the kinetics of electron transfer reactions [1], DVA can visualise phase transitions by correlating the opencircuit voltage and exchanged charge [2]. Recently, DVA receives an increasing attention in the battery community for characterising full-cell setups. In contrast, CV is less prominent for batteries, yet the prevalently used technique for ex-situ characterisations of novel electrode materials in half-cell configuration.
In this study, we have investigated the overdischarge process of LiFePO4 pouch cells – which is usually presumed to result in a decomposition of the solid electrolyte interphase (SEI) and a corrosion of the copper current collector – in a complementary electrochemical analysis which uses both, CV and DVA in full-cell mode. For this purpose, CV consisting of three low sweep-rate scans and DVA of three low current rate cycles was performed. Degradation was traced by successive CV/DVA sequences during, pre- and post-overdischarge which allowed to pinpoint the features, the limitations, and similarities of both techniques.
In this manner, we demonstrate that CV can successfully identify the dynamics of degradation processes, indicating that an irreversible side reaction starts at cell voltages below 0.55 V. For this reason, this study underlines that CV can be effectively used for spotting dynamic degradation mechanisms which are hardy seen in DVA. This may pave the way for further analysis which can be used for fingerprinting characteristic degradation.…


| Autor*innen: | Philippa ScharpmannORCiD |
|---|---|
| Koautor*innen: | Robert LeonhardtORCiD, Anita SchmidtORCiD, Julia KowalORCiD, Tim TichterORCiD |
| Dokumenttyp: | Vortrag |
| Veröffentlichungsform: | Präsentation |
| Sprache: | Englisch |
| Jahr der Erstveröffentlichung: | 2025 |
| Organisationseinheit der BAM: | 3 Gefahrgutumschließungen; Energiespeicher |
| 3 Gefahrgutumschließungen; Energiespeicher / 3.1 Sicherheit von Gefahrgutverpackungen und Batterien | |
| DDC-Klassifikation: | Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Angewandte Physik |
| Freie Schlagwörter: | Batteries; Cyclic Voltammetry; Differential Voltage Analysis |
| Themenfelder/Aktivitätsfelder der BAM: | Energie |
| Energie / Elektrische Energiespeicher und -umwandlung | |
| Veranstaltung: | 124. Bunsentagung 2025 |
| Veranstaltungsort: | Leipzig, Germany |
| Beginndatum der Veranstaltung: | 17.03.2025 |
| Enddatum der Veranstaltung: | 19.03.2025 |
| Verfügbarkeit des Dokuments: | Datei im Netzwerk der BAM verfügbar ("Closed Access") |
| Datum der Freischaltung: | 09.12.2025 |
| Referierte Publikation: | Nein |
| Eingeladener Vortrag (wissenschaftliche Konferenzen): | Nein |