Experimental and reaction kinetic study of hydrogen ignition behavior at ignition limits
- The paper presents the results of an experimental and reaction kinetic investigation of hydrogen ignition at different pressures in a closed vessel, highlighting its non-linear behavior and the effects of radical wall termination. The reaction kinetic simulation predicts the three characteristic ignition limits of hydrogen caused by radical and thermal auto-ignition and is in close agreement with the experimental measurements. The first ignition limit is determined by the chain branching reaction H+O_2→O+ OH. This limit shows strong sensitivity towards the wall termination of O, H and OH radicals. The second ignition limit is influenced by the wall termination of O, H, OH, HO2 and H2O2 radicals. The third ignition limit is dominated by the reaction paths HO_2+HO_2→H_2 O_2+O_2 and H_2 O_2+M→2 OH+M, which is why it shows strong sensitivity towards wall termination of HO₂ and H₂O₂ radicals. Increasing the radical wall termination rate by increasing the sticking coefficient of the radicalsThe paper presents the results of an experimental and reaction kinetic investigation of hydrogen ignition at different pressures in a closed vessel, highlighting its non-linear behavior and the effects of radical wall termination. The reaction kinetic simulation predicts the three characteristic ignition limits of hydrogen caused by radical and thermal auto-ignition and is in close agreement with the experimental measurements. The first ignition limit is determined by the chain branching reaction H+O_2→O+ OH. This limit shows strong sensitivity towards the wall termination of O, H and OH radicals. The second ignition limit is influenced by the wall termination of O, H, OH, HO2 and H2O2 radicals. The third ignition limit is dominated by the reaction paths HO_2+HO_2→H_2 O_2+O_2 and H_2 O_2+M→2 OH+M, which is why it shows strong sensitivity towards wall termination of HO₂ and H₂O₂ radicals. Increasing the radical wall termination rate by increasing the sticking coefficient of the radicals at the wall or the surface-to-volume-ratio leads to an increase of the auto-ignition temperature at the same pressure. The introduction of radical wall termination reactions improved the prediction of ignition limits and highlighted the profound effect of the autoclave wall and vessel size on the hydrogen ignition behavior.…


| Autor*innen: | Hayat El HarrabORCiD, Enis AskarORCiD, T. FrankenORCiD, F. Mauss |
|---|---|
| Dokumenttyp: | Zeitschriftenartikel |
| Veröffentlichungsform: | Verlagsliteratur |
| Sprache: | Englisch |
| Titel des übergeordneten Werkes (Englisch): | Proceedings of the Combustion Institute |
| Jahr der Erstveröffentlichung: | 2025 |
| Organisationseinheit der BAM: | 2 Prozess- und Anlagensicherheit |
| 2 Prozess- und Anlagensicherheit / 2.1 Sicherheit von Energieträgern | |
| Veröffentlichende Institution: | Bundesanstalt für Materialforschung und -prüfung (BAM) |
| Verlag: | Elsevier Inc. |
| Jahrgang/Band: | 41 |
| Aufsatznummer: | 105980 |
| Erste Seite: | 1 |
| Letzte Seite: | 7 |
| DDC-Klassifikation: | Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Angewandte Physik |
| Freie Schlagwörter: | Auto-ignition Temperature; Hydrogen; Ignition Limit; Radical Wall Termination Reaction |
| Themenfelder/Aktivitätsfelder der BAM: | Energie |
| Energie / Wasserstoff | |
| DOI: | 10.1016/j.proci.2025.105980 |
| URN: | urn:nbn:de:kobv:b43-647609 |
| ISSN: | 1540-7489 |
| Verfügbarkeit des Dokuments: | Datei für die Öffentlichkeit verfügbar ("Open Access") |
| Lizenz (Deutsch): | Creative Commons - CC BY - Namensnennung 4.0 International |
| Datum der Freischaltung: | 19.11.2025 |
| Referierte Publikation: | Ja |
| Datum der Eintragung als referierte Publikation: | 01.12.2025 |