Cryogenic storage system behaviour under fire : A study of the insulation impact

  • The transition from fossil fuels to low-emission alternatives is essential to mitigate carbon emissions in energy-intensive sectors. Liquid hydrogen (LH2) is a promising energy carrier due to its high gravimetric energy density, but its storage requires advanced insulation to minimize heat ingress and prevent excessive boil-off losses. Multilayer insulation (MLI), perlite, and microspheres are commonly used under vacuum conditions, yet their performance under fire exposure remains a critical concern. This study investigates the thermal degradation of insulation materials and its impact on heat transfer in an event with extreme thermal load conditions using the Cryogenic High-Temperature Thermal Vacuum Chamber (CHTTVC). The heat flow dynamics are analyzed, and an equivalent heat transfer coefficient is proposed to quantify the impact of insulation deterioration as the outer wall temperature increases. Additionally, a novel liquid-vapor interface monitoring method is introduced toThe transition from fossil fuels to low-emission alternatives is essential to mitigate carbon emissions in energy-intensive sectors. Liquid hydrogen (LH2) is a promising energy carrier due to its high gravimetric energy density, but its storage requires advanced insulation to minimize heat ingress and prevent excessive boil-off losses. Multilayer insulation (MLI), perlite, and microspheres are commonly used under vacuum conditions, yet their performance under fire exposure remains a critical concern. This study investigates the thermal degradation of insulation materials and its impact on heat transfer in an event with extreme thermal load conditions using the Cryogenic High-Temperature Thermal Vacuum Chamber (CHTTVC). The heat flow dynamics are analyzed, and an equivalent heat transfer coefficient is proposed to quantify the impact of insulation deterioration as the outer wall temperature increases. Additionally, a novel liquid-vapor interface monitoring method is introduced to improve real-time detection of phase changes within the tank. The results highlight that insulation failure substantially increases the heat flow, which, if not mitigated, can lead to boiling liquid expanding vapor explosions (BLEVE), jet fires, or catastrophic tank failure. The findings provide valuable insights into optimizing LH2 storage safety and improving emergency response strategies for cryogenic tanks exposed to extreme thermal conditions.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • ID290_Presentation_ICHS2025.pdf
    eng

Metadaten exportieren

Weitere Dienste

Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Aliasghar Hajhariri, Robert EberweinORCiD
Dokumenttyp:Vortrag
Veröffentlichungsform:Präsentation
Sprache:Englisch
Jahr der Erstveröffentlichung:2025
Organisationseinheit der BAM:3 Gefahrgutumschließungen; Energiespeicher
3 Gefahrgutumschließungen; Energiespeicher / 3.5 Sicherheit von Gasspeichern und Gefahrguttanks
DDC-Klassifikation:Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Angewandte Physik
Freie Schlagwörter:Cryogenic; Heat transfer; Liquid Hydrogen; Multi-Layer Insulation
Themenfelder/Aktivitätsfelder der BAM:Energie
Energie / Wasserstoff
Veranstaltung:11th International Conference on Hydrogen Safety ICHS 2025
Veranstaltungsort:Seoul, South Korea
Beginndatum der Veranstaltung:22.09.2025
Enddatum der Veranstaltung:25.09.2025
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:26.09.2025
Referierte Publikation:Nein