Fire Test Stand for Thermal Testing of Large Packages for the Transport of Radioactive Materials
- Packages for the transport of spent nuclear fuel are designed to withstand severe accidents and must ensure compliance with the IAEA-Regulations prescribing mechanical tests followed by a thermal test. The thermal test involves that a test specimen is exposed to a thermal environment for 30 minutes, simulating the conditions of a hydrocarbon fuel-air fire. The average fire temperature is at least 800°C, and the fire completely engulfs the test specimen. In advance of a regular fire test, BAM performs so-called fire reference tests or calorimeter tests with a fire reference package (FRP) to determine the test conditions for compliance with the IAEA-requirements.
| Autor*innen: | Thomas Quercetti |
|---|---|
| Koautor*innen: | Martin Feldkamp, Tobias GleimORCiD, André Musolff, Jan Werner, Frank Wille |
| Dokumenttyp: | Posterpräsentation |
| Veröffentlichungsform: | Präsentation |
| Sprache: | Englisch |
| Jahr der Erstveröffentlichung: | 2025 |
| Organisationseinheit der BAM: | 3 Gefahrgutumschließungen; Energiespeicher |
| 3 Gefahrgutumschließungen; Energiespeicher / 3.3 Sicherheit von Transportbehältern | |
| DDC-Klassifikation: | Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Angewandte Physik |
| Freie Schlagwörter: | Experiment; Fire; Thermal Test |
| Themenfelder/Aktivitätsfelder der BAM: | Energie |
| Energie / Kerntechnische Entsorgung | |
| Veranstaltung: | PATRAM 2025 |
| Veranstaltungsort: | San Antonio, TX, USA |
| Beginndatum der Veranstaltung: | 27.07.2025 |
| Enddatum der Veranstaltung: | 01.08.2025 |
| Verfügbarkeit des Dokuments: | Datei im Netzwerk der BAM verfügbar ("Closed Access") |
| Datum der Freischaltung: | 06.08.2025 |
| Referierte Publikation: | Nein |