Enhancement of Fire Test Stand Performance at Test Site of BAM: Installation and Evaluation of an Augmented System with a Fire Reference Package

  • Packages for the transport of radioactive material are designed to endure severe accidents. Packages for the transportation of radioactive material must demon-strate that the package can withstand certain prescribed tests from the IAEA Reg-ulations [1]. In addition to mechanical tests, a thermal test in form of a fire test must be carried out. As packages to be tested at BAM are significantly larger than previous package designs, BAM has expanded an existing fire test stand. A modular concept is chosen, which means that the arrangement of the burner noz-zles can be adapted to the test specimen. The dimensions of the burner rings, the type, the orientation and the number of burner nozzles can be varied depending on the test specimen. In addition, various pumps can be used to set the corre-sponding mass flow. With the help of a calorimeter test, the fire test stand can be qualified for a specific size of packages regarding the boundary conditions of the IAEA Regulations [1]. Due to thePackages for the transport of radioactive material are designed to endure severe accidents. Packages for the transportation of radioactive material must demon-strate that the package can withstand certain prescribed tests from the IAEA Reg-ulations [1]. In addition to mechanical tests, a thermal test in form of a fire test must be carried out. As packages to be tested at BAM are significantly larger than previous package designs, BAM has expanded an existing fire test stand. A modular concept is chosen, which means that the arrangement of the burner noz-zles can be adapted to the test specimen. The dimensions of the burner rings, the type, the orientation and the number of burner nozzles can be varied depending on the test specimen. In addition, various pumps can be used to set the corre-sponding mass flow. With the help of a calorimeter test, the fire test stand can be qualified for a specific size of packages regarding the boundary conditions of the IAEA Regulations [1]. Due to the typically wood filled impact limiters in German package designs, a fire test is necessary, as experiments have shown that possible openings that occurred during a mechanical test contributed to the ignition of the wood filled impact limiters within the prescribed 30 minutes of the IAEA Regula-tions [1]. From a series of experiments, two experiments are presented to show the possibilities to obtain different temperatures and temperature rates in the test specimen. In addition to sensor data, the heat flux into the package is calculated to verify that the IAEA boundary conditions are satisfied. In addition to the tem-perature data, other data such as wind speed and wind direction are also recorded to explain subsequent effects in the measurement data in a comprehensible man-ner.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • WFS_Presentation_Gm.pdf
    eng

Metadaten exportieren

Weitere Dienste

Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Tobias GleimORCiD
Koautor*innen:Frank Wille, M. Feldkamp, T. Quercetti, A. Musolff, J. Werner
Dokumenttyp:Vortrag
Veröffentlichungsform:Präsentation
Sprache:Englisch
Jahr der Erstveröffentlichung:2025
Organisationseinheit der BAM:3 Gefahrgutumschließungen; Energiespeicher
3 Gefahrgutumschließungen; Energiespeicher / 3.3 Sicherheit von Transportbehältern
DDC-Klassifikation:Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Angewandte Physik
Freie Schlagwörter:Accident Scenario; Fire Qualification; Fire Test Stand; IAEA Regulations
Themenfelder/Aktivitätsfelder der BAM:Energie
Energie / Kerntechnische Entsorgung
Veranstaltung:Sandia-BAM Technical Exchange
Veranstaltungsort:Albuquerque, NM, USA
Beginndatum der Veranstaltung:23.07.2025
Enddatum der Veranstaltung:24.07.2025
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:06.08.2025
Referierte Publikation:Nein
Eingeladener Vortrag (wissenschaftliche Konferenzen):Nein
Einverstanden