Superparamagnetic Bead-Based Microfluidic Fluoroimmunoassay Platform for Rapid Ochratoxin A Detection in Flour

  • Simplification and reduction of time and costs are the primary goals in the development and use of onsite methods in diagnostics and food safety. To facilitate the transition from laboratory techniques to simple, miniaturized devices, we have developed a modular microfluidic platform. This platform integrates a competitive fluorescence immunoassay on the surface of superparamagnetic beads, serving as a complementary technique to traditional cytometry assays. In the first chip module, a fast competitive reaction (5 min) occurs, after which the particles are retained in the second module. This module consists of a PDMS chip and a permanent magnet, allowing only the fluorescent competitor to reach the detection module. Ochratoxin A (OTA) was chosen as the model analyte for device development, using fluorescein-labeled OTA as a competitor. The system efficiently separates particles, with OTA concentration directly correlated to the amount of fluorescent competitor remaining in solutionSimplification and reduction of time and costs are the primary goals in the development and use of onsite methods in diagnostics and food safety. To facilitate the transition from laboratory techniques to simple, miniaturized devices, we have developed a modular microfluidic platform. This platform integrates a competitive fluorescence immunoassay on the surface of superparamagnetic beads, serving as a complementary technique to traditional cytometry assays. In the first chip module, a fast competitive reaction (5 min) occurs, after which the particles are retained in the second module. This module consists of a PDMS chip and a permanent magnet, allowing only the fluorescent competitor to reach the detection module. Ochratoxin A (OTA) was chosen as the model analyte for device development, using fluorescein-labeled OTA as a competitor. The system efficiently separates particles, with OTA concentration directly correlated to the amount of fluorescent competitor remaining in solution after the competitive reaction. This innovative setup allows to perform rapid measurements with small sample volumes in a short time (10 min), achieving a limit of detection for OTA of 1.2 μg L–1. The system was successfully applied to the accurate determination of OTA in wheat flour spiked at regulatorily relevant concentrations. Using this device, conventional cytometry immunoassays can be seamlessly transformed into user-friendly, miniaturized analytical methods at reduced cost for applications outside of a laboratory directly at the point of need.zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Daniel López-PuertollanoORCiD, Charlie TobiasORCiD, Jérémy BellORCiD, A. Abad-SomovillaORCiD, A. Abad-FuentesORCiD, Knut RurackORCiD
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):ACS Sensors
Jahr der Erstveröffentlichung:2025
Organisationseinheit der BAM:1 Analytische Chemie; Referenzmaterialien
1 Analytische Chemie; Referenzmaterialien / 1.9 Chemische und optische Sensorik
Veröffentlichende Institution:Bundesanstalt für Materialforschung und -prüfung (BAM)
Verlag:American Chemical Society
Verlagsort:Washington, D.C.
Erste Seite:1
Letzte Seite:10
DDC-Klassifikation:Naturwissenschaften und Mathematik / Chemie / Analytische Chemie
Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Sanitär- und Kommunaltechnik; Umwelttechnik
Freie Schlagwörter:Bead-based assay; Fluorescence; Immunoassay; Microfluidics; mycotoxins
Themenfelder/Aktivitätsfelder der BAM:Chemie und Prozesstechnik
Chemie und Prozesstechnik / Chemische Charakterisierung und Spurenanalytik
Umwelt
DOI:10.1021/acssensors.5c01119
URN:urn:nbn:de:kobv:b43-638472
ISSN:2379-3694
Verfügbarkeit des Dokuments:Datei für die Öffentlichkeit verfügbar ("Open Access")
Lizenz (Deutsch):License LogoCreative Commons - CC BY - Namensnennung 4.0 International
Datum der Freischaltung:04.08.2025
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:11.08.2025
Schriftenreihen ohne Nummerierung:Wissenschaftliche Artikel der BAM
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.