Initial VOC Emissions from Consumer Products Determined in Micro-Scale Test Chambers: Results of a Round Robin Test

  • Emissions of volatile organic compounds (VOCs) from consumer products may have a negative impact on indoor air quality, potentially also affecting human wellbeing. Since consumers may be exposed to these VOCs immediately after e.g. unwrapping of newly purchased products, reliable analytical methods are needed to determine air concentration profiles in the early phase of VOC emissions. Concerning typical sample sizes of consumer products, micro-scale test chambers (μ-chambers) were considered suitable for this purpose. In addition, compared to medium- or large-scale test chambers, μ-chambers require lower initial investment and operational costs, and offer options for emissions screenings where higher sample throughput is essential. For these reasons, a μ-chamber-based method to determine initial concentrations of VOCs emitting within the first hours of simulated product use was developed. The chamber air was frequently sampled on desorption tubes loaded with Tenax® TA, followed byEmissions of volatile organic compounds (VOCs) from consumer products may have a negative impact on indoor air quality, potentially also affecting human wellbeing. Since consumers may be exposed to these VOCs immediately after e.g. unwrapping of newly purchased products, reliable analytical methods are needed to determine air concentration profiles in the early phase of VOC emissions. Concerning typical sample sizes of consumer products, micro-scale test chambers (μ-chambers) were considered suitable for this purpose. In addition, compared to medium- or large-scale test chambers, μ-chambers require lower initial investment and operational costs, and offer options for emissions screenings where higher sample throughput is essential. For these reasons, a μ-chamber-based method to determine initial concentrations of VOCs emitting within the first hours of simulated product use was developed. The chamber air was frequently sampled on desorption tubes loaded with Tenax® TA, followed by quantification of emitted VOCs via thermal desorption gas chromatography mass spectrometry (TD-GC-MS). The method was assessed in a round robin test involving eight participating laboratories from 2 countries. Pieces of a rain poncho (sample area A: 2.01·10-4 m2) emitting cyclohexanone, phenol, 2-ethylhexanol, naphthalene and isophorone in significant concentrations were distributed as sample material. Each laboratory conducted triplicate emission tests over a period of 48 h in μ-chambers with volumes of 44 or 114 mL. The loading factors L of 4.57 m2·m-3 (44 mL) or 1.76 m2·m-3 (114 mL) and air flow rates of 24 mL·min-1 resulted in area-specific air flow rates q of 7.17 m3·m-2·h-1 in both chamber types. The temperature was set to 23°C and, if possible, relative humidity was set to approx. 50%. The chamber air was sampled after 0.5, 1, 2, 4, 24 and 48 hours. In addition, to assess the analytical performance, each participating laboratory received two analyte-spiked Tenax® TA-loaded desorption tubes for quality control (QC). Very low relative standard deviations (11–17%) were obtained for the QC test. The results of the emissions tests in the early phase (0.5–4 h) were also adequate, with acceptable z scores (|z|≤2.00) received by six to seven participating laboratories. All eight laboratories obtained acceptable z scores after the longer sampling periods (24 and 48 h). Hence, the inter-laboratory comparability of the results obtained with the developed μ-chamber method was successfully confirmed.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • Abstract_HB25.pdf
    eng
  • Vortrag_HB25.pdf
    eng

Metadaten exportieren

Weitere Dienste

Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Olaf WilkeORCiD, Birte Poelke, Luise Klein, Alexander Rohloff, Holger Hoffmann
Koautor*innen:Olaf Wilke
Dokumenttyp:Vortrag
Veröffentlichungsform:Präsentation
Sprache:Englisch
Jahr der Erstveröffentlichung:2025
Organisationseinheit der BAM:1 Analytische Chemie; Referenzmaterialien
1 Analytische Chemie; Referenzmaterialien / 1.4 Non-Target-Analytik
4 Material und Umwelt
4 Material und Umwelt / 4.5 Kunst- und Kulturgutanalyse
DDC-Klassifikation:Naturwissenschaften und Mathematik / Chemie / Analytische Chemie
Freie Schlagwörter:Consumer Product; Round Robin Test; Test Chamber; VOC Emissions
Themenfelder/Aktivitätsfelder der BAM:Chemie und Prozesstechnik
Chemie und Prozesstechnik / Chemische Charakterisierung und Spurenanalytik
Veranstaltung:Healthy Buildings Europe 2025
Veranstaltungsort:Reykjavik, Iceland
Beginndatum der Veranstaltung:08.06.2025
Enddatum der Veranstaltung:11.06.2025
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:18.07.2025
Referierte Publikation:Nein
Eingeladener Vortrag (wissenschaftliche Konferenzen):Nein
Einverstanden