Approaches towards sensitive and reliable determination of trifluoroacetic acid (TFA) from German grass- and farmland soils

  • In light of the emerging threat of environmental contamination from per- and polyfluoroalkyl substances (PFAS), there is a growing need for analytical techniques that can be applied to a range of environmental matrices, including water, air, plant, and soil samples. Trifluoroacetic acid (TFA) is a member of the PFAS class, representing the shortest perfluorinated carboxylic acid and is an emerging pollutant whose environmental levels are expected to increase in the future. Soil matrices represent the interface between plant and ecosystem uptake of TFA, but contamination is poorly understood, largely due to a lack of uniform TFA determination methods. This study compares six ways of determining TFA in soils and highlights their limitations. We present a validated sample preparation method with high recoveries (104 %), low LOD (0.015 ng/g) and LOQ (0.045 ng/g). This approach includes isotope dilution analysis with hydrophilic interaction liquid chromatography coupled to tandem massIn light of the emerging threat of environmental contamination from per- and polyfluoroalkyl substances (PFAS), there is a growing need for analytical techniques that can be applied to a range of environmental matrices, including water, air, plant, and soil samples. Trifluoroacetic acid (TFA) is a member of the PFAS class, representing the shortest perfluorinated carboxylic acid and is an emerging pollutant whose environmental levels are expected to increase in the future. Soil matrices represent the interface between plant and ecosystem uptake of TFA, but contamination is poorly understood, largely due to a lack of uniform TFA determination methods. This study compares six ways of determining TFA in soils and highlights their limitations. We present a validated sample preparation method with high recoveries (104 %), low LOD (0.015 ng/g) and LOQ (0.045 ng/g). This approach includes isotope dilution analysis with hydrophilic interaction liquid chromatography coupled to tandem mass spectrometry (HILIC-MS/MS) detection. The method was applied to quantify the TFA content in 100 soil samples from grassland and farmland across Germany. The results indicate the ubiquity of TFA, accompanied by elevated contamination levels in certain locations. An analysis of variance revealed no correlation with collection site and designation purpose. However, a low correlation was observed with dry bulk density.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • Approaches towards sensitive and reliable determination of TFA from German soils.pdf
    eng

Metadaten exportieren

Weitere Dienste

Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Juliane SchollORCiD, Emelie MeiersORCiD, Tatjana Mauch, Jan LisecORCiD, Thomas Sommerfeld, Karlheinz Weinfurtner, Hajo HaaseORCiD, Matthias KochORCiD
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Chemosphere
Jahr der Erstveröffentlichung:2025
Organisationseinheit der BAM:1 Analytische Chemie; Referenzmaterialien
1 Analytische Chemie; Referenzmaterialien / 1.7 Organische Spuren- und Lebensmittelanalytik
Verlag:Elsevier
Verlagsort:Amsterdam
Jahrgang/Band:382
Aufsatznummer:144496
Erste Seite:1
Letzte Seite:11
DDC-Klassifikation:Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Sanitär- und Kommunaltechnik; Umwelttechnik
Freie Schlagwörter:Emerging pollutant; Extraction methods; German soil protection; HILIC-MS/M; PFAS
Themenfelder/Aktivitätsfelder der BAM:Umwelt
Umwelt / Umwelt-Material-Interaktionen
DOI:10.1016/j.chemosphere.2025.144496
ISSN:0045-6535
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:26.06.2025
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:26.06.2025
Paper des Monats:Ja
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.