Measurements of Photoluminescence Quantum Yields of Scattering LED Converter Materials

  • How to Get it Right with the Absolute Measurement of Photoluminescence Quantum Yields of Scattering LED Converter Materials Saskia Fiedler+,a, Florian Frenzel+,a, Christian Würth a, Isabella Tavernaro a, Michelle Grüne c, Stefan Schweizer c,d, Axel Engel e, and Ute Resch-Genger a* a Division Biophotonics, Federal Institute for Materials Research and Testing (BAM), Richard-Willstaetter-Strasse 11, D-12489 Berlin, Germany; email: ute.resch@bam.de b Present address: Photonic Materials, NWO-Institute AMOLF, Science Park 104, 1098 XG Amsterdam, The Netherlands c Faculty of Electrical Engineering, South Westphalia University of Applied Sciences, Lübecker Ring 2, 59494, Soest, Germany d Fraunhofer Application Center for Inorganic Phosphors, Branch Lab of Fraunhofer Institute for Microstructure of Materials and Systems IMWS, Lübecker Ring 2, 59494, Soest, Germany e Schott AG Technical Services, Hattenbergstrasse 10, D-55122 Mainz, Germany Optical measurements of scattering materials such asHow to Get it Right with the Absolute Measurement of Photoluminescence Quantum Yields of Scattering LED Converter Materials Saskia Fiedler+,a, Florian Frenzel+,a, Christian Würth a, Isabella Tavernaro a, Michelle Grüne c, Stefan Schweizer c,d, Axel Engel e, and Ute Resch-Genger a* a Division Biophotonics, Federal Institute for Materials Research and Testing (BAM), Richard-Willstaetter-Strasse 11, D-12489 Berlin, Germany; email: ute.resch@bam.de b Present address: Photonic Materials, NWO-Institute AMOLF, Science Park 104, 1098 XG Amsterdam, The Netherlands c Faculty of Electrical Engineering, South Westphalia University of Applied Sciences, Lübecker Ring 2, 59494, Soest, Germany d Fraunhofer Application Center for Inorganic Phosphors, Branch Lab of Fraunhofer Institute for Microstructure of Materials and Systems IMWS, Lübecker Ring 2, 59494, Soest, Germany e Schott AG Technical Services, Hattenbergstrasse 10, D-55122 Mainz, Germany Optical measurements of scattering materials such as luminescent nano- and microparticles and phosphors dispersed in liquid and solid matrices play an important role in energy conversion, solid-state lighting, medical diagnostics, and security barcoding. A key performance parameter is the photoluminescence quantum yield QY, i.e., the number of emitted per number of absorbed photons. QY of transparent luminophore solutions can be obtained relative to a fluorescence QY standard of known QY, meanwhile available as certified reference materials.[1] The determination of QY of scattering liquid and solid samples like nanoparticle dispersions, phosphors, and optoceramics requires, however, absolute measurements with an integrating sphere setup. Despite the need for reliable absolute QY measurements, no interlaboratory comparison (ILCs) on measurement uncertainties has been performed and scattering standards with known QY are not available. We present the results of an ILC of 3 labs from academia and industry on measurements of transparent and scattering dye solutions and solid phosphors and converter materials like YAG:Ce optoceramics with commercial stand-alone integrating sphere setups of different illumination and detection geometries. Special emphasis was dedicated to the influence of measurement geometry, optical properties of the blank for determining the number of incident photons absorbed by the sample, and sample-specific surface roughness. Matching QY values could be obtained for transparent dye solutions and scattering dispersions with a blank with scattering properties closely matching those of the sample, QY measurements of optoceramic samples with different blanks revealed substantial differences of more than 20 %. Based on our data, we recommend non-absorbing blank materials with a high reflectivity (>95 %) such as a 2 mm-thick PTFE target placed on the sample holder as blanks.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • QY-Scat-new design_3004_2025.pdf
    eng
  • Abstract 03137_PLQY_2801_2025.pdf
    eng

Metadaten exportieren

Weitere Dienste

Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Ute Resch-GengerORCiD
Koautor*innen:S. Fiedler, Florian Frenzel, Maria Richter, Arne Güttler, Christian Würth
Dokumenttyp:Posterpräsentation
Veröffentlichungsform:Präsentation
Sprache:Englisch
Jahr der Erstveröffentlichung:2025
Organisationseinheit der BAM:1 Analytische Chemie; Referenzmaterialien
1 Analytische Chemie; Referenzmaterialien / 1.2 Biophotonik
DDC-Klassifikation:Naturwissenschaften und Mathematik / Chemie / Analytische Chemie
Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Ingenieurwissenschaften und zugeordnete Tätigkeiten
Freie Schlagwörter:Absolute quantum yield; Advanced materials; Calibration; Characterization; Electron microscopy; Film; Fluorescence; ILC; Integrating sphere spectroscopy; LED converter; Lifetime; Measurement uncertainty; NIR; Nano; Particle; Quality assurance; Quantum yield; YAG:Ce
Themenfelder/Aktivitätsfelder der BAM:Chemie und Prozesstechnik
Chemie und Prozesstechnik / Chemische Charakterisierung und Spurenanalytik
Material
Material / Advanced Materials
Umwelt
Veranstaltung:eMRS
Veranstaltungsort:Strasbourg, France
Beginndatum der Veranstaltung:26.05.2025
Enddatum der Veranstaltung:30.05.2025
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:11.06.2025
Referierte Publikation:Nein
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.